Home IC695GCG001 GE Fanuc RX3i PACSystems Genius Communication Interface
IC695GCG001
IC695GCG001
IC695GCG001
IC695GCG001
IC695GCG001
IC695GCG001

IC695GCG001 GE Fanuc RX3i PACSystems Genius Communication Interface

  • Manufacturer: GE Fanuc

  • Product No.: IC695GCG001

  • Condition: In stock

  • Product Type: Communications Gateway Module

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview

The Emerson Automation IC695GCG001 acts as a high-efficiency Genius communication gateway for demanding industrial control environments.

This intelligent unit bridges legacy network infrastructure into modern PACSystems RX3i hardware architectures seamlessly.

It provides a reliable migration path, allowing plants to retain legacy field blocks without full system decommissioning.

Control engineers deploy this interface to map serial field bus signals directly into high-speed Ethernet control layers.

Technical Specifications

  • Core Identification: Originally designed by GE Fanuc, now manufactured by Emerson Automation. The specific model number is IC695GCG001.
  • Module Classification: Functions as a dedicated network conversion bridge belonging to the PACSystems RX3i series.
  • Physical Interfaces: Equipped with 2 RJ45 Ethernet ports and 2 specialized serial Genius network connection points.
  • Device Capacity: Scans, controls, and manages up to 31 distinct Genius blocks or remote field stations simultaneously.
  • Data Payload Matrix: Allocates a robust data allowance of 1024 bytes of input data and 1024 bytes of output data per gateway unit.
  • Bus Transmission Speeds: Supports both 153.6 Kbps Standard and 153.6 Kbps Extended serial network data transmission speeds.
  • Power Requirements: Demands an external 24 VDC power supply connection, drawing a maximum current of 0.19 Amperes.
  • Update Production Rates: Features software-configurable data cyclic intervals of 2ms, 4ms, 8ms, 16ms, 32ms, 128ms, 256ms, or 512ms.
  • Network Topology Support: Integrates smoothly into both linear bus and star network physical structural layouts.
  • Thermal Operating Limits: Withstands operational ambient temperatures ranging precisely from 0 degrees C up to 60 degrees C.

Installation Guide

First, mount the gateway module securely onto a standard industrial enclosure panel or via an expansion slot kit.

Connect the external 24 VDC power supply cables to the marked terminal block following correct polarity guidelines.

Terminate your existing serial bus drops into the designated Serial 1, Serial 2, and Shield network ports.

Insert the PROFINET network Ethernet cables directly into the built-in RJ45 communication interface communication ports.

Verify all grounding parameters match plant electrical safety codes before turning on the external power source.

Ensure the front panel status indicators show normal operation before loading your automated hardware configurations.

Debugging and Maintenance Convenience

The onboard SD card slot facilitates quick firmware updates and allows rapid backing up of vital network configurations.

Clearly labeled front-panel markings for Shield In, Shield Out, and Serial lines simplify manual field tracing tasks.

The module supports structural hot-swapping routines, allowing rapid maintenance transitions when external power is disconnected.

Technicians easily reference internal diagnostic statistics over standard web browsers or network monitoring management software suites.

Compatibility Notes

This network bridge links natively with high-performance controllers including RX3i CPE330 and RX3i CPE302 units.

The internal bridging firmware interfaces smoothly with RX3i CPE305, CPE310, CPU315, CPU320, and CRU320 processing architectures.

The Ethernet ports support full protocol integration with any standard industrial GE PROFINET input-output controller card.

The software stack provides built-in alignment for standard network layers including UDP, IP, ARP, and ICMP messaging.

Supported Protocol Suite

  • RTC – Real Time Cyclic Protocol (Class 1 and Class 2 Unsynchronized)
  • RTA – Real Time Acyclic Protocol
  • DCP – Discovery and Configuration Protocol
  • CL-RPC – Connectionless Remote Procedure Call
  • LLDP – Link Layer Discovery Protocol
  • MRP – Media Redundancy Protocol for Ethernet ring architectures
  • SNMP – Simple Network Management Protocol

Packing List and Warranty Terms

The factory box delivers 1 genuine Emerson Automation IC695GCG001 communication gateway interface block.

The shipping container includes industrial anti-static packaging safeguards along with the basic startup terminal wiring manual.

This communication device includes a complete 12-month product warranty clause against all functional manufacturing failures.

The active warranty coverage tracking automatically activates upon the physical delivery date to your plant destination.

Shipping Logistics

Our fulfillment infrastructure guarantees fast order dispatch processing within 24 to 48 hours of payment confirmation.

We execute international express delivery utilizing the world's most reliable premium logistics networks including FedEx, UPS, and DHL.

Your purchasing department receives instant shipping tracking notifications via email immediately upon product warehouse departure.

Typical Application Scenarios

Automobile manufacturing plants implement this gateway to connect older assembly line drops into centralized Ethernet networks.

Pulp and paper mills deploy the module to migrate extensive legacy motor control blocks to modern controllers.

Water treatment infrastructure facilities utilize the interface to bridge distributed remote pump stations into a PROFINET ring.

Diagnostic Capabilities

The gateway performs continuous active scanning of connected serial nodes to instantly isolate down stations.

Built-in Media Redundancy Protocol controls identify ring network breaks and redirect data paths within milliseconds.

Integrated priority tagging and VLAN support allow engineers to diagnose and filter critical control traffic from background data.

Global PLC Spare HUB's Insight

The Emerson Automation IC695GCG001 provides plant managers an incredible financial advantage during complex system upgrades.

Instead of rewiring dozens of physical field blocks, this single module bridges old and new architectures instantly.

The dual RJ45 ports give you built-in network flexibility, easily supporting linear, star, or redundant ring setups.

It is an essential component for heavy infrastructure plants looking to transition to Ethernet without massive downtime budgets.

Selection Guide

Confirm your total combined field device requirements do not exceed the 31 maximum station limit per gateway.

Calculate your network bandwidth needs to ensure the 1024-byte input and output limits accommodate your data layout.

Verify that your main central processor model is explicitly listed in our controller compatibility index before ordering.

Ensure you have a separate external 24 VDC power distribution channel ready to supply the necessary 0.2 Amps.

Frequently Asked Questions (FAQ)

Question: Can I copy or save my existing network configuration data onto the integrated SD card interface?

Answer: Yes, the SD card slot supports full backing up of Ethernet configuration profiles and simplifies firmware loading updates.

Question: Does this gateway module allow hot-swapping while the external power supply line remains live?

Answer: No, you must completely disconnect the external 24 VDC power supply before executing a hot-swap hardware replacement.

Question: What is the maximum data size this module can exchange with a PROFINET controller?

Answer: The hardware handles a maximum data capacity of 1024 bytes of input and 1024 bytes of output data.

Question: How does the Media Redundancy Protocol function help my plant maintain continuous operational control?

Answer: MRP allows the Ethernet ports to form a redundant ring topology that keeps communicating if a cable breaks.

Question: What specific baud rates are supported across the serial field network interfaces?

Answer: The module supports standard industrial serial communications running at either 153.6 Kbps Standard or Extended speeds.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.