Home IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module
IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module

IC695CMX128 GE Fanuc RX3i PACSystems Control Memory Xchanger Module

  • Manufacturer: GE Fanuc

  • Product No.: IC695CMX128

  • Condition: In stock

  • Product Type: Memory Xchange Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview

The IC695CMX128 is a high-speed PACSystems Control Memory Xchanger module engineered by GE Fanuc for the RX3i platform. Operating as a high-performance reflective memory node, this module enables deterministic, real-time data sharing across up to 256 interconnected network nodes without processor overhead.

Built with 128 MB of SDRAM, the module delivers an extraordinary network transfer throughput of up to 174 Mbytes/s over fiber-optic links. It integrates seamlessly into any RX3i Universal Backplane, establishing low-latency memory mapping across complex control architectures.

Technical Specifications

Part Number IC695CMX128
Brand & Series GE Fanuc / PACSystems RX3i
Module Type Control Memory Xchanger (CMX) / Reflective Memory
Onboard Memory 128 MB SDRAM
Bus Transmission Speed 2.1 Gbits/sec serial bus speed
Network Transfer Rate 43 Mbyte/s to 174 Mbytes/s burst transfer
Packet Architecture Dynamic packet size ranging from 4 to 68 bytes
Power Consumption 253 mA @ +5 VDC | 660 mA @ +3.3 VDC
Physical Interfaces Dual LC-type fiber optic ports (Bottom transceiver)
Optical Connection Multimode fiber optic cable (up to 300 meters distance)
Network Capacity Supports up to 256 nodes in a ring topology
Hardware Compatibility VMIC 5565 series reflective memory devices
Programming Software Proficy Machine Edition Logic Developer v5.80 or later
Form Factor & Weight Single-slot Universal Backplane module | 1.0 lb (0.45 kg)

Hardware Architecture & Diagnostics

  • OK LED Indicator: Displays CPU interface health and power availability across internal rails.
  • CONFIG LED Indicator: Signals successful parameter initialization via Proficy Machine Edition software.
  • SIG DETECT LED Indicator: Confirms active optical carrier signal reception on the LC fiber port.
  • OWN DATA LED Indicator: Highlights packet transmission and valid loop ring loopback verification.
  • Advanced Fault Registers: Allows firmware querying of parity errors, packet drops, and interrupt register flags.

Target Applications & Compatibility

  • Deterministic Power Generation: Links multiple RX3i racks in turbine control systems demanding sub-millisecond data synchronization.
  • Hybrid VMIC Networks: Interfaces directly with legacy VMIC 5565 nodes in high-speed data acquisition rings.
  • Complex Pipeline Operations: Coordinates multi-PLC interlocking without fieldbus polling overhead.

Installation & Commissioning Guidelines

  • Topology Layout: Wire nodes in a strict closed ring topology (TX of Node 1 to RX of Node 2).
  • Cable Limits: Use high-quality multimode fiber cables without exceeding the 300-meter segment limit.
  • Rack Seating: Power down the rack before inserting the single-slot module into an RX3i Universal Backplane.

Packaging, Logistics & Warranty

  • Dispatch SLA: Ships globally within 24 to 48 hours of order confirmation.
  • Logistics Partners: Express delivery via DHL, FedEx, and UPS with full shipment tracking.
  • Anti-Static Packaging: Sealed in ESD-shielded enclosure to preserve delicate optical and memory components.
  • 12-Month Coverage: Protected by a complete 12-month replacement warranty against hardware defects.

Engineering Buyer's Guide

  • Verify Software Revision: Confirm your engineering environment runs Proficy Machine Edition v5.80 or higher before deployment.
  • Calculate Optical Margins: Measure total optical attenuation across patch panels to prevent signal loss on extended loops.
  • Standardize Node IDs: Map dynamic packet sizes early during network design to optimize total loop latency.

Frequently Asked Questions (FAQ)

Q: Is the IC695CMX128 module drop-in compatible with standard GE VMIC 5565 fiber networks?

A: Yes, this unit integrates directly into existing VMIC 5565 reflective memory loops using standard LC optical patch leads.

Q: How does dynamic packet sizing affect memory latency in large networks?

A: Dynamic payload sizing (4 to 68 bytes) minimizes protocol overhead, keeping node-to-node transfer jitter negligible even at 256-node limits.

Q: What causes the SIG DETECT LED to stay off after plugging in fiber cables?

A: This indicates optical loss; verify fiber polarity (TX/RX inversion), clean LC connectors, or check for fiber bends exceeding minimum radius limits.

Q: Can this module be installed in a standard expansion baseplate instead of a Universal Backplane?

A: No, it requires high-speed PCI bus access provided exclusively by the RX3i Universal Backplane slots.

Q: How do field technicians verify parity errors on the reflective memory bus?

A: Program logic accesses diagnostic registers directly via logic blocks in Proficy Machine Edition to monitor hardware parity flags in real time.

Global PLC Spare HUB's Insight

During a field retrofit at a power generation facility, our engineering team diagnosed intermittent data drops on an RX3i control ring. The customer reported that the IC695CMX128 node frequently lost frame synchronization during peak plant load.

Our signal analysis revealed that an unshielded fiber jumper was pinched behind a high-voltage tray, dropping light levels near the receiver's threshold. Once we routed armored multimode fiber, cleaned the LC connectors, and reset the node parameters in Proficy Machine Edition, the loop achieved a solid 2.1 Gbit/s throughput. Always verify optical power levels before commissioning high-speed reflective memory rings!

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.