GE Fanuc IC695ALG626 PACSystems RX3i Series HART Analog Module
Manufacturer: GE Fanuc
Product No.: IC695ALG626
Condition: In stock
Product Type: Analog Input Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
IC695ALG626 GE Fanuc RX3i Analog Input Module IC695ALG626 - Best Deal
Global PLC Spare HUB Review evaluates the IC695ALG626 module as an advanced, HART-enabled analog input interface engineered for precision process control loops. Global PLC Spare HUB's Insight reveals that its combination of 24-bit ADC resolution, 4 internal HART modems, and flexible single-ended or differential channel configurations provides plant operators with exceptional diagnostic visibility and signal fidelity. Control engineers specify this module to handle demanding multi-variable measurements across complex industrial networks.
Part Number Configuration Layout Matrix
PACSystems RX3i Analog Input Architecture Breakdown: ├── System Platform: PACSystems RX3i Modular Controller Series ├── Module Part Number: IC695ALG626 (16-Channel Analog Input with HART) ├── Communication Protocol: HART Version 5.0 Capable via 4 Internal Modems └── Channel Architecture: Software-Configurable Single-Ended or Differential Input
Core Technical Specifications Table
| Technical Parameter | Engineering Specification |
|---|---|
| Brand & Model | GE Fanuc / IC695ALG626 |
| Product Series & Type | PACSystems RX3i Series / Non-Isolated Analog Input Module w/ HART |
| Channel Capacity | 16 single-ended or 8 differential input channels |
| Voltage & Current Ranges | Voltage: ±10V, 0-10V, ±5V, 0-5V, 1-5V; Current: 0-20mA, 4-20mA, ±20mA |
| Conversion Resolution | 24-bit ADC converted to floating point or integer data format |
| Backplane Power Requirements | 3.3V DC at 600 mA; 5V DC at 450 mA via universal backplane |
Machinery Suitability and Diagnostic Capabilities
- Target Equipment: Integrated into process skids, petrochemical refining units, water treatment plants, and distributed automation loops utilizing smart field transmitters.
- Diagnostic Focus: Features onboard error monitoring, open-circuit detection (1 second max for 4–20 mA loops), positive/negative rate-of-change alarms, high-high/low-low alarm limits, and hardware status LEDs (Module OK, Field Status, TB LED) to isolate wiring faults instantly.
Supply Chain, Fulfillment, and Warranty Terms
- Fulfillment Logistics: Rapid dispatch within 24 to 48 hours utilizing premier global carriers including FedEx, UPS, and DHL.
- Warranty Protection: Fully backed by an exclusive 12-month replacement and performance guarantee from Global PLC Spare HUB.
Frequently Asked Questions
Why is it mandatory to configure the current range to 4 to 20 mA when utilizing HART communications on the IC695ALG626?
HART communication signals are modulated over the standard 4 to 20 mA analog current loop; operating outside this specific current window disrupts the frequency shift keying (FSK) super-imposed digital data stream.
How do I interpret the front-panel Field Status LED when it displays a solid yellow color?
A yellow indicator means that at least one enabled input channel on the module has encountered a fault condition, such as an out-of-range signal or open circuit.
Can I hot-swap the IC695ALG626 module on an active RX3i universal backplane without powering down the rack?
Yes. The module supports Removal and Insertion Under Power (RIUP), allowing technicians to replace or service the hardware safely while the control system remains fully operational.
What configuration steps are required to switch between single-ended and differential input wiring modes?
All channel configurations are handled entirely through software via Proficy Machine Edition, eliminating the need to adjust physical hardware jumpers or DIP switches on the module circuit board.
What factors should I consider when selecting input filter frequencies for noisy industrial environments?
Selecting a lower filter frequency (such as 8 Hz or 12 Hz) helps attenuate high-frequency electrical noise from nearby variable frequency drives, though it will slightly increase signal response time.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



