CA901 Vibro-Meter 144-901-000-252 Piezoelectric Accelerometer Sensor
Manufacturer: Vibro-Meter
Product No.: 144-901-000-252
Condition: In stock
Product Type: Piezoelectric Accelerometer Sensor
Product Origin: USA
Payment: T/T, Western Union
Weight: 680g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Global PLC Spare HUB's Insight
- The CA901 (144-901-000-252) is a specialized piezoelectric sensor for extreme environments.
- While standard sensors fail at 150°C, the CA901 maintains precision up to 700°C.
- It is the industrial "gold standard" for Nuclear Loose Part Monitoring Systems (LPMS).
- The Inconel 600 hermetic housing ensures signal linearity under high radiation flux.
Product Introduction
- The Vibro-Meter CA901 is a high-reliability piezoelectric charge-mode accelerometer.
- It generates a charge signal proportional to acceleration without requiring external input power.
- Please download the CA901 installation guide for specific fastening torque requirements.
- This sensor meets NRC 1.133 and IEEE 323-1974 standards for critical safety applications.
Configuration Breakdown
- CA901 Base Model (Piezoelectric Charge Technology)
- └── 144-901 Series (Standard High-Temp Qualified Design)
- └── 000 Version (Original Industrial/Nuclear Specification)
- └── Connector 2 (VM Lemo High-Temperature Type)
- └── Lead 52 (8-Meter Integrated Armored Cable)
- └── Final PN: 144-901-000-252
Technical Specifications
- Brand: Vibro-Meter (Meggitt Energy)
- Model Number: CA901
- Part Number: 144-901-000-252
- Sensitivity: 10 pC/g ±5% calibrated at 120 Hz
- Frequency Range: 3 Hz to 2800 Hz (Nominal response)
- Measurement Range: 0.001 g to 200 g peak dynamic acceleration
- Temperature Tolerance: Cryogenic -196°C up to extreme +700°C
- Resonance Frequency: > 17 kHz nominal (Mounted state)
- Material: Inconel 600 housing, hermetically welded construction
- Radiation Resistance: Withstands Gamma flux 10^11 erg/g and Neutron flux 10^18 n/cm²
- Explosive Certification: ATEX Zone 0, 1, 2 (Ex ia IIC T6 to T710)
- Internal Insulation: Minimum 10^9 Ω resistance at room temperature
Diagnostic Capabilities
- The CA901 utilizes a 2-pole system insulated from the casing to reduce EMI noise.
- Maintenance teams can perform "Insulation Resistance Monitoring" to detect cable degradation.
- Real-time leakage testing between poles and casing identifies moisture ingress in field wiring.
- Differential signal transmission effectively cancels common-mode interference in heavy motor areas.
Typical Application Scenarios
- Nuclear Power Plants: Primary circuit Loose Part Monitoring (LPMS) according to NRC 1.133.
- Gas Turbines: Monitoring vibration in exhaust sections and high-temp turbine casings.
- Cryogenic Engineering: Monitoring liquid nitrogen pumps and rocket fuel handling systems.
- High-Pressure Reactors: Vibration analysis in chemical processes up to 140 bar pressure.
Shipping and Warranty Logistics
- Shipping Carriers: Fast global delivery via FedEx, UPS, and DHL.
- Dispatch Time: In-stock orders are shipped within 24-48 hours.
- Warranty Policy: Includes a comprehensive 12-month technical warranty.
- Packaging: Secured in custom anti-vibration foam to protect sensitive piezoelectric crystals.
Professional FAQ & Purchasing Guide
- Does the 144-901-000-252 require a specific charge amplifier?
- Yes, as a charge-output sensor, it must be paired with a charge converter (e.g., IPC704) for signal conditioning.
- What is the selection logic for the "52" suffix in the CA901 model?
- The "52" indicates a factory-fitted 8-meter cable, which is critical for maintaining calibrated capacitance.
- How critical is the mounting torque for the CA901?
- Extremely critical. You must use a torque wrench to apply exactly 15 Nm to the 4 Allen M6 screws for accurate data.
- Can this sensor be used in direct reactor core monitoring?
- It is qualified for high radiation flux (10^18 n/cm²), making it suitable for secondary containment and primary loop zones.
- How do I diagnose a drop in sensor sensitivity?
- Verify the internal insulation resistance; if it falls below 10^9 Ω, the cable or sensor seal may be compromised.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.