BMENOS0300C Modicon X80 Switch Module Schneider Electric Network
Manufacturer: Schneider Electric
Product No.: BMENOS0300C
Condition: In stock
Product Type: Switch Module
Product Origin: DE
Payment: T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
BMENOS0300C Architectural Overview
The BMENOS0300C is a ruggedized, three-port managed network switch module engineered explicitly for the Modicon X80 automation platform. This intelligent hardware delivers dedicated routing for EtherNet/IP device networks and specialized local service ports. Built for harsh processing environments, the assembly features comprehensive factory conformal coating as standard reinforcement. The infrastructure mounts natively into intelligent industrial backplanes to facilitate high-speed data multiplexing and deterministic control communication. Control engineers deploy this component to optimize sub-network topologies, isolate control traffic, and maintain uninterrupted uptime across demanding automation backbones.
Technical Specifications
- Brand: Schneider Electric
- Model Number: BMENOS0300C
- Product Series: Modicon X80 Platform
- Module Type: Managed Ethernet Switch Module
- Total Ports: 3 Communications Interface Channels
- Port Routing Assignment: Dedicated EtherNet/IP Device Network and Local Service Port Access
- Communication Protocol: Native EtherNet/IP Industrial Layer
- Rated Supply Input Voltage: 24 V DC Sourced via the Backplane Bus
- Thermal Power Consumption at 25 °C: 3.3 W Maximum Drawing 135 mA Current
- Thermal Power Consumption at 60 °C: 4.5 W Maximum Drawing 185 mA Current
- Physical Module Format: Standard Expansion Slot Occupancy Profile
- Ingress Protection Rating: IP20 Sealed Housing Design
- Overvoltage Protection Standard: Category II Certified Circuit Protection
- Net Component Weight: 264.0 Grams
Environmental Resiliency & Harsh Atmosphere Ratings
- Chemical Gas Immunity Level: Gas Resistant Class Gx Conformant to ISA S71.04 Standards
- Industrial Gas Immunity Standard: Gas Resistant Class 3C4 Conformant to IEC 60721-3-3
- Particulate Matter Immunity: Dust Resistant Class 3S4 and Sand Resistant Class 3S4 to IEC 60721-3-3
- Atmospheric Moisture Protection: Mold Growth and Fungal Spore Resistant Class 3B2 (IEC 60721-3-3)
- Marine Air Resiliency: Salt Resistant Level 2 Conformant to IEC 68252 Compliance Matrix
- Hazardous Boundary Classification: Hazardous Location Class I Division 2 Rated Architecture
- Explosive Area Safety Registry: ATEX Zone 2/22 and IECEx Zone 2/22 Explosion Protection
Substation & Heavy Industrial Standards Profile
- Power Utility Substation Certification: EN/IEC 61850-3 Location G Compliant
- Automation Interface Specifications: EN/IEC 61000-6-5 Interface Type 1 and Type 2
- Programmable Controllers General Criteria: EN/IEC 61131-2 Structural Standards
- Electrical Laboratory Safety Requirements: EN/IEC 61010-2-201, UL 61010-2-201, and CSA C22.2 No 61010-2-201
- Marine Environmental Type Approval: International Association of Classification Societies IACS E10
Climatic & Operational Thresholds
- Operational Ambient Temperature: 0 to 60 Degrees Celsius with No Thermal Derating Required
- Storage Ambient Temperature: -40 to 85 Degrees Celsius Extended Thermal Envelope
- Relative Ambient Humidity: 95% Continuous Non-condensing Maximum Limit
- Operational Atmospheric Altitude: Less than or Equal to 2000 Meters Above Sea Level
- Logistical Transport Altitude: Maximum Peak Limit up to 3000 Meters
System Integration & Equipment Suitability
- Intelligent Backplane Architectures: Modicon BMEXBP Ethernet+X-Bus Mixed Backplanes (BMEXBP0400, BMEXBP0800)
- Automation Processor Nodes: Modicon M580 ePAC CPU Controllers (BMEP582040, BMEP584040)
- Distributed I/O System Architectures: Modicon Quantum / Premium Transition Drops via X80 Remote Architecture
- Severe Corrosive Environments: Petrochemical Processing Facilities and Wastewater Treatment Operations
Application Scenarios
- Segregation of real-time machine interlocking data traffic from upper-level SCADA polling lines.
- Providing isolated local engineering access terminals directly on the equipment enclosure door via the service port.
- Ethernet communication distribution within localized sub-rings utilizing specialized industrial redundancy rings.
- Remote telemetry network interface deployment in corrosive, humid coastal environments or salt-heavy installations.
- High-density data routing inside electrical power distribution sub-stations requiring strict surge protection compliance.
Diagnostic Capabilities
- RUN LED (Green): Steady illumination confirms the network module firmware is fully initialized and operational.
- ERR LED (Red): Signals an internal microprocessor failure, hardware lock, or active device error condition.
- Mod Status LED (Green/Red): Double-color light providing visual confirmation of the overall module logic configuration.
- Net Status LED (Green/Red): Double-color light displaying real-time connection handshake health across the network fabric.
Compliance & Certifications
- CE Mark Safety Directives
- Low Voltage Framework Directive 2014/35/EU
- Electromagnetic Compatibility Directive 2014/30/EU
- ATEX Explosive Atmospheres Safety Directive 2014/34/EU
- Underwriters Laboratories Industrial Control Safety UL Listed
- Canadian Standards Association Industrial Systems CSA Certified
- Regulatory Compliance Mark RCM / Eurasian Conformity Certification EAC
Packaging Dimensions & Logistical Units
- Package Type 1 Unit: Individual PCE Container Layout
- Package Type 1 Envelope Dimensions: 5.800 cm (Height) x 11.200 cm (Width) x 12.200 cm (Length)
- Package Type 1 Dead Weight: 264.000 Grams Total
- Package Type 2 Bulk Unit: S02 Multi-Pack Shipping Carton containing 5 individual modules
- Package Type 2 Envelope Dimensions: 15.000 cm (Height) x 30.000 cm (Width) x 40.000 cm (Length)
- Package Type 2 Bulk Weight: 1.636 Kilograms
- Package Contents: One Network Switch Unit, Factory Inspection Record, Technical Reference Manual
- Hardware Protection Term: 12-Month Factory Defects Warranty Coverage Agreement
Shipping Logistics
- Authorized Freight Networks: Expedited international shipping via FedEx, UPS, and DHL.
- Processing Speed: Secured global transit dispatch routines complete within 24 to 48 hours of order processing.
Global PLC Spare HUB's Insight
The BMENOS0300C stands out because it brings advanced electrical substation and chemical resistance metrics right down to the standard I/O rack level. While typical Ethernet modules fail rapidly under exposure to hydrogen sulfide or high humidity, this module handles aggressive environments seamlessly due to its severe duty conformal coating. The dual certification under Class I Div 2 and ATEX Zone 2 allows engineers to safely extend high-speed Ethernet fabrics into hazardous areas. It reduces the footprint required for extra networking hardware by combining control routing and local field maintenance ports onto a single, backplane-powered slot.
Procurement Selection Matrix
- Specify the "C" denoted conformal-coated variant if your plant atmosphere has corrosive elements or high humidity.
- Confirm your target backplane is an Ethernet-compatible BMEXBP rack variant to match the high-speed data traces.
- Ensure your current power supply calculation includes the higher 185 mA current consumption profile if operating near the 60 °C upper thermal boundary.
- Avoid using this infrastructure module for wide-area fiber optic distribution without external media converters since all native connections are copper ports.
Frequently Asked Questions
What design purpose does the "C" suffix indicate for this communication interface card?
The "C" suffix means the printed circuit board has a factory conformal coating. This protective layer shields the internal circuits from dust, salt air, chemical gases, and fungal growth in harsh environments.
Can this card be plugged into an older standard TSXBPX series X-Bus backplane?
No. The network module requires an Ethernet-enabled BMEXBP series backplane. It uses the specific high-speed Ethernet pins that are not present on older legacy X-Bus racks.
How does the module manage the difference between critical machine control data and local engineering traffic?
The card uses integrated firmware mapping. This setup isolates the service port traffic from the deterministic EtherNet/IP loop data, preventing localized diagnostic tasks from delaying real-time control routines.
What does a steady red ERR illumination signify on the front plate during startup?
A solid red ERR lamp indicates a critical internal hardware fault or a corrupted firmware issue. If cycling the rack power does not clear the error, the module may need service or replacement.
Does the module require external 24 V DC power wiring to function on the rack drop?
No. The unit draws its operating power directly from the backplane bus. You do not need to wire any external power terminals to activate the device ports.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.