Bently Nevada 21022-27-05-017-03 Dual Axial Probe Housing Assembly
Manufacturer: Bently Nevada
Product No.: 21022-27-05-017-03
Condition: In stock
Product Type: Dual Axial Probe Housing
Product Origin: USA
Payment: T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Engineering Overview: Precision Thrust Position Monitoring
The 21022-27-05-017-03 is a mission-critical Dual Axial Probe Housing Assembly from Bently Nevada. Specifically engineered to house two proximity probes, this assembly allows for redundant axial thrust position measurement of rotating shafts. Mounted at the machine end nearest to the thrust bearing, it provides a rugged, environmentally sealed interface that complies with API 670 standards, ensuring reliable monitoring of shaft displacement even in high-dust or splash-prone industrial areas.
Configuration Breakdown
The following table outlines the technical specifications for the 21022-27-05-017-03:
- Model: 21022 (Dual Axial Probe Housing)
- Probe Option (27): 3300 XL NSv Probe
- Cable Length (05): 0.5 metre (20 in)
- Penetration (017): 1.7 in
- Fittings (03): Dual seal grips + 3/4" to 1/2" NPT reducers
Global PLC Spare HUB’s Insight
For rotating equipment, thrust bearing failure is often catastrophic. The 21022-27-05-017-03 offers a distinct advantage: its dual-probe configuration allows for "voting" logic (e.g., 2-out-of-2), which significantly reduces the risk of false trips in safety-instrumented systems. We recommend this unit for installations where maintenance teams require external access to adjust probe gaps without disassembling the machine casing—a massive time-saver during annual turnarounds.
Industrial Applications, Diagnostics & Logistics
- Suitable Equipment: Large centrifugal compressors, gas and steam turbines, and industrial blowers with critical thrust bearings.
- Diagnostic Capability: Enables continuous, high-fidelity tracking of shaft axial position. The design ensures that probes, leads, and extension cables are protected from environmental factors, resulting in stable, low-noise DC gap voltage signals.
- Warranty: Professional 12-month factory-grade quality guarantee.
- Shipping: Expedited global transit via FedEx, UPS, or DHL; 24–48 hour dispatch.
Model Comparison & Technical Advice
Technical comparison for your selection process:
- 21022-27-05-017-03 (Current Selection): Configured for NSv probes with 1.7-inch penetration.
- 21022-28-10-XXX-02: Utilizes a standard 3300 XL probe and longer cable configuration.
Technical Suggestion: When selecting between NSv (Non-Standard velocity/small range) and standard XL probes, ensure your proximity driver matches the sensor technology. The 21022-27-05-017-03 is specifically tuned for high-accuracy, small-target axial measurements.
Expert Frequently Asked Questions
Why is dual-probe monitoring required for axial thrust?
Redundancy is critical for machine safety. If one probe fails or provides an erroneous signal, the second probe acts as a confirmation source to prevent an unnecessary and expensive emergency machine shutdown.
Can I install the fittings after the housing is mounted?
Yes, the fittings are supplied as a kit. We recommend installing them during the final cable routing phase to ensure the cable seals are properly tightened for maximum IP ingress protection.
What is the purpose of the 0.3% copper-free aluminum alloy?
This material is standard in marine and offshore environments to prevent galvanic corrosion when the housing is exposed to salt-laden air, significantly extending the service life compared to standard cast iron or steel.
How does the API 670 compliance benefit my site operations?
Compliance guarantees that the probe-to-shaft alignment, mechanical strength, and environmental sealing meet internationally recognized safety benchmarks for machinery protection.
Is there any specific calibration required after mounting?
While the probes are set at the factory, the final "cold gap" must be verified with a feeler gauge or depth micrometer after mounting the assembly to ensure the probe tip is at the correct linear range distance from the shaft shoulder.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.