Home AGP813-S10 Yokogawa AGS813 High-Speed Protection I/O Module

AGP813-S10 Yokogawa AGS813 High-Speed Protection I/O Module

  • Manufacturer: Yokogawa

  • Product No.: AGP813-S10

  • Condition: In stock

  • Product Type: I/O Module

  • Product Origin: SG

  • Payment: T/T, Western Union

  • Weight: 280g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Yokogawa AGP813-S10 | AGS813 High-Speed Protection Module

Rotating machinery protection depends on accurate signal acquisition and predictable I/O response. The Yokogawa AGP813-S10 is identified as a turbomachinery I/O module associated with the AGS813 High-Speed Protection Module family.

This module supports isolated voltage inputs, digital inputs, and current-sinking digital outputs. Its high-speed configuration uses a 5 ms scan cycle, while the basic configuration uses a 10 ms scan cycle, according to the supplied specifications.

Engineers can use these characteristics to evaluate signal interfaces and system integration requirements. Before installation, verify the exact model designation, channel allocation, dedicated cable, and host-system compatibility.

01 | Product Identity and Configuration Breakdown

Identification Field Description
Manufacturer Yokogawa
Product Number AGP813-S10
Associated Model AGS813
Product Type Turbomachinery I/O Module
Module Function High-Speed Protection Module, isolated
External Connection Dedicated cable connection
Compatible Cable References AKB337-M005, AKB337-M007, AKB337-M010
Approximate Weight 0.28 kg

Suffix and Configuration Breakdown

  • AGS813
    • Identifies the associated high-speed protection module model.
    • The supplied description specifies an isolated I/O configuration.
  • -S
    • Standard type.
  • 1
    • Defined as “Always 1” in the supplied suffix information.
    • Confirm the manufacturer's formal code definition before using this digit to determine functional behavior.
  • 0
    • Basic type, according to the supplied suffix information.
    • Confirm how this designation relates to the high-speed and basic I/O cycle specifications for the ordered assembly.

Ordering note: The supplied information identifies AGP813-S10 as the product number and AGS813 as the associated model. Confirm this relationship against the equipment nameplate and Yokogawa documentation before ordering.

02 | Electrical Specifications at a Glance

Parameter Specification
Voltage Input Channels 4 isolated channels at high-speed cycle; 6 isolated channels at basic cycle
Voltage Input Signal 1–5 V
Voltage Input Accuracy ±4 mV
Temperature-Related Drift ±4 mV per 10 °C ambient temperature change
Input Impedance, Powered 1 MΩ, as supplied
Input Impedance, Unpowered 100 kΩ, as supplied
Allowable Input Voltage 30 VDC
Filtering Collective filtering
Digital Input Channels 4 isolated channels at high-speed cycle; 8 isolated channels at basic cycle
Digital Input Type 24 VDC sink
Input ON Voltage 18–26.4 VDC
Input OFF Voltage 5 VDC or less
Input Current 4.1 mA ±20%
Maximum Digital Input Voltage 30 VDC
Digital Output Channels 4 isolated channels at high-speed cycle; 8 isolated channels at basic cycle
Digital Output Type Current sinking
Maximum Output Load 100 mA per channel at 30 VDC
Maximum ON Voltage 0.3 VDC, as supplied
Maximum OFF-State Leakage 0.1 mA
Typical ON/OFF Delay 1 ms
High-Speed Scan Cycle 5 ms
Basic Scan Cycle 10 ms
System-to-Field Withstand Voltage 500 VAC for 1 minute
Different I/O Type Withstand Voltage 500 VAC for 1 minute
Maximum Power Consumption 900 mA at 5 VDC
Weight Approximately 0.28 kg

Engineering clarification: The listed 900 mA at 5 VDC represents a calculated power of 4.5 W. Confirm whether this is the applicable maximum consumption for the specific hardware configuration.

03 | Signal Interfaces and I/O Behavior

The module combines analog voltage measurement with discrete input and output functions. Correct signal matching is essential for reliable operation and meaningful diagnostics.

  • Voltage Acquisition: The 1–5 V input range supports compatible voltage-output devices. Confirm signal scaling and source impedance.
  • Digital State Detection: The 24 VDC sink input interface requires compatible field wiring and valid ON/OFF voltage levels.
  • Digital Output Control: Current-sinking outputs support loads within the stated 100 mA per-channel limit.
  • Electrical Isolation: The specifications list 500 VAC withstand voltage for the stated isolation boundaries.
  • Signal Filtering: Collective filtering affects signal processing. Verify its configuration and effect on fast-changing signals.

Do not connect an inductive load directly without confirming the output's permitted load characteristics and required suppression. The current rating alone does not establish compatibility with every relay, solenoid, or actuator.

04 | Application Areas and Equipment Integration

The product is intended for turbomachinery I/O applications. Actual equipment compatibility depends on the host protection system, supported interfaces, and approved system configuration.

Application Potential Use Verification Required
Steam Turbine Control Acquisition of compatible voltage signals and discrete status inputs Confirm the installed protection architecture and signal mapping
Gas Turbine Systems High-speed I/O interfacing within a supported turbomachinery system Verify controller compatibility and approved module configuration
Rotating Machinery Protection Interface for designated analog and digital signals Confirm sensor interface, response requirements, and trip logic
Power Generation Control cabinet integration and maintenance replacement Check the equipment bill of materials and revision requirements
Industrial Machinery Monitoring Signal acquisition and discrete equipment status handling Confirm I/O range, wiring method, and environmental requirements

Selection boundary: The available specifications do not establish a particular turbine model or protection-system series as compatible. Verify the exact host equipment before purchase.

05 | Installation and Commissioning Sequence

  1. Confirm the Part Number: Match AGP813-S10 with the equipment nameplate and approved parts list.
  2. Verify the Host System: Confirm the supported rack, interface, and I/O configuration using Yokogawa documentation.
  3. Select the Correct Cable: Check whether AKB337-M005, AKB337-M007, or AKB337-M010 matches the installation.
  4. Inspect the Connectors: Check the cable ends and module interface for damage, contamination, or bent contacts.
  5. Verify Signal Wiring: Match voltage inputs, digital inputs, and sinking outputs to the approved terminal diagram.
  6. Check Electrical Limits: Confirm input voltage, output load current, polarity, and grounding arrangements.
  7. Test Input Values: Compare known reference signals with displayed or recorded values.
  8. Test Digital Functions: Verify ON/OFF recognition, output operation, and timing under approved test conditions.
  9. Record Commissioning Results: Document channel mapping, observed values, alarms, and any configuration changes.

Field tip: Do not assume that the basic configuration offers the same channel count or scan timing as the high-speed configuration. Confirm the selected operating mode before assigning channels.

06 | Troubleshooting and Diagnostic Guide

Observed Symptom First Checks Engineering Interpretation
Voltage readings are consistently offset Check source accuracy, common reference, wiring, and configured scaling Helps distinguish signal-source errors from input configuration issues
Voltage values drift with temperature Compare measurements across operating temperatures and check the signal source Evaluate source drift against the specified module drift
Digital input does not turn ON Measure input voltage and verify sink wiring and polarity Check whether the signal reaches the specified ON threshold
Digital output cannot operate the load Verify load current, circuit wiring, and output configuration Identify overloads or incompatible load arrangements
Output device remains partially energized Check OFF-state leakage and the load's minimum operating current Determine whether leakage affects the connected device
Fast signal transitions are missed Review scan mode, filtering, pulse duration, and test setup Assess whether timing settings affect signal recognition

Field example: A technician observes that a digital input does not change state during a turbine auxiliary-system test. The technician measures the input voltage and compares it with the ON threshold. The technician then checks the sink wiring, field contact, and channel assignment. This method isolates common wiring and configuration issues before module replacement.

For protection-related faults, follow the approved plant procedure. Do not bypass protective interlocks or alter trip thresholds to conceal an unresolved signal problem.

07 | Global PLC Spare HUB's Insight

High-speed protection I/O selection requires careful attention to channel availability, signal levels, and response timing. A module that matches the connector may still be unsuitable if its I/O mode differs from the installed configuration.

For AGP813-S10, engineers should verify the model relationship, suffix interpretation, dedicated cable, and required scan mode before installation. During commissioning, use calibrated signal sources and approved test procedures to compare input readings with known values.

For example, if a 1–5 V channel shows an offset, check the source reference and wiring before adjusting the control configuration. If a digital output fails to switch a field device, verify the sinking output arrangement and load current against the specified limit.

These checks provide a repeatable troubleshooting path and help prevent unnecessary replacement of functioning hardware.

08 | Packaging, Warranty, and Shipping

  • Product: Yokogawa AGP813-S10 Turbomachinery I/O Module
  • Associated Model: AGS813 High-Speed Protection Module
  • Package Contents: One module, subject to order confirmation. Dedicated cables and accessories are included only when explicitly specified.
  • Warranty: 12 months, subject to applicable seller warranty terms.
  • Shipping Methods: FedEx, UPS, or DHL, depending on destination and service availability.
  • Dispatch Target: Typically 24–48 hours after order confirmation, subject to stock availability and processing.

Contact Global PLC Spare HUB to confirm availability, exact configuration, package contents, warranty coverage, and shipping arrangements before ordering.

09 | Certification and Compliance

The supplied specifications include electrical withstand voltage ratings but do not identify specific independent safety or hazardous-area approvals.

Confirm applicable product declarations and system-level certifications before using the module in a regulated protection application. Do not infer a safety integrity level from the term “High-Speed Protection Module” alone.

10 | Frequently Asked Questions

Q1: How do I determine whether the 5 ms scan cycle is suitable for my signal?

Compare the required event duration and response time with the module's documented scan behavior, filtering, and system processing. Validate the complete signal path through approved commissioning tests.

Q2: What should I check when a 1–5 V measurement differs from a reference instrument?

Verify the source output, measurement reference, cable condition, channel configuration, and instrument calibration. Compare the observed error with the specified ±4 mV accuracy and temperature-related drift, while confirming the manufacturer's test conditions.

Q3: Can every digital output drive a 100 mA load continuously?

The supplied rating specifies a maximum load of 100 mA per channel at 30 VDC. Confirm the permitted operating conditions, total module loading, load type, and any derating requirements before use.

Q4: How should I select between the listed dedicated cable lengths?

Check the cabinet layout, connector compatibility, routing path, and required service clearance. Confirm the precise cable part number and length from the equipment documentation before placing an order.

Q5: What information should I provide when ordering a replacement module?

Provide the full product number, host-system model, required I/O mode, cable reference, and installation details. A nameplate photograph and existing parts-list entry can help verify the correct configuration.

Request a Quote for AGP813-S10

Need the Yokogawa AGP813-S10 turbomachinery I/O module for maintenance or system integration? Contact Global PLC Spare HUB for pricing, availability, and compatibility review.

Include the associated AGS813 model information, host-system details, required quantity, and destination. Our team can use these details to help verify the product identification before quotation.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.