8920-PS-DC Power Supply MTL Instruments 8000 IS Module
Manufacturer: MTL
Product No.: 8920-PS-DC
Condition: In stock
Product Type: Power Supply Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Power Distribution & Redundancy Architecture
The 8920-PS-DC engineered by MTL Instruments within the MTL8000 distributed process I/O platform functions as a high-reliability DC-to-DC intrinsically safe (IS) module power supply. Delivering a regulated 12 V DC output at up to 5 A capacity, this unit powers up to eight Zone 2/1 IS I/O modules simultaneously while supporting active load sharing for N+1 redundant system architectures.
Electrical & Efficiency Specifications
| Parameter | Specification |
|---|---|
| Manufacturer & Series | MTL Instruments / MTL8000 Series |
| Model Designation | 8920-PS-DC IS Module DC Power Supply |
| Nominal & Range Input Voltage | 24 V DC nominal (18.5 to 36 V DC wide operational span) |
| Regulated Output Rating | 12 V DC ± 5% at 5 A continuous capacity (drives up to 8 IS modules) |
| Full-Load Conversion Efficiency | 76% (at 18.5 V / 4.1 A); 78% (at 24 V / 3.3 A); 76.5% (at 36 V / 2.1 A) |
| Galvanic & Safety Isolation | 250 V AC rms input-to-output isolation (1500 V AC rms dielectric test); voltage clamped output (Un = 18 V) |
| Redundancy Capability | Supports parallel load sharing for fault-tolerant power distribution |
| Input Termination | Duplicated 2-part screw terminals accepting up to 2.5 mm² conductors |
Hazardous Area Approvals & Compliance
- Installation Zone Rating: Approved for Safe Area, Class I, Division 2 (Groups A, B, C, D), and Zone 2, IIC T4 hazardous locations.
- Intrinsic Safety Standards: Complies with FM Class 3610 / 3611, EN 50020:1994 (Intrinsic Safety "i"), and ATEX Directive 94/9/EC.
- EMC & Electrical Safety: Tested to EN 50081-2, EN 50082-2, EN 61000-3-2/3, EN 61010-1, and EN 61131-2.
Mechanical & Environmental Resilience
- Carrier Mounting Interface: Mounts directly onto 8724-CA-PS power supply carriers; dimensions 84 (W) × 110 (H) × 160 (D) mm; weight 1290 g.
- Thermal Operating Envelope: -40 °C to +55 °C at full load (optimum orientation); -40 °C to +50 °C (worst-case orientation); up to +70 °C at 60% load without forced cooling.
- Storage & Humidity: -40 °C to +85 °C storage range; 5% to 95% non-condensing relative humidity.
- Mechanical Shock & Vibration: 2 g vibration (10–100 Hz per BS EN 60068-2-6) and 10 g shock (11 ms pulse per BS EN 60068-2-27).
- Corrosion & Reliability: ISA SP71.04 Level G3 corrosive atmosphere tolerance inside suitable enclosures; IP20 ingress protection; 80,000 hours MTBF at 50 °C external ambient.
Installation & Commissioning Guidelines
- Carrier Alignment: Seat the 8920-PS-DC firmly onto the 8724-CA-PS carrier backplane and verify all supply connectors lock mechanically to maintain IP20 rating.
- Duplicated Bus Wiring: Utilize the duplicated 2-part screw terminals (max 2.5 mm² wire) to daisy-chain 24 V DC bulk power cleanly across adjacent carriers without external terminal blocks.
- Orientation Planning: Mount carriers in the manufacturer-specified optimum orientation to preserve the full +55 °C continuous full-load thermal rating.
Package Contents
- 1 × MTL Instruments 8920-PS-DC IS Module DC Power Supply
- 1 × Duplicated 2-Part Input Screw Terminal Connector Set
- 1 × Hazardous Area Control Drawing & Safety Instruction Sheet
Engineering FAQ & Field Troubleshooting
Q1: How does carrier mounting orientation impact maximum allowable cabinet ambient temperature?
A1: Mounting the 8724-CA-PS carrier in its optimum vertical airflow orientation allows full 5 A load operation up to +55 °C. Horizontal or restricted-airflow orientations derate the continuous full-load ceiling to +50 °C due to natural convection limits.
Q2: What happens if a single power supply fails in a dual-redundant load-sharing configuration?
A2: Because the 8920-PS-DC incorporates active load-sharing circuitry, the surviving parallel unit seamlessly assumes 100% of the 12 V DC bus load (up to 8 IS modules) without voltage dip or process I/O interruption.
Q3: Why is the 12 V DC output voltage clamped at Un = 18 V?
A3: Intrinsic safety barrier certification (EN 50020 / FM 3610) mandates infallible crowbar/zener voltage clamping so fault transients never inject incendive energy levels into downstream Zone 1 or Division 1 field circuits.
Q4: Can this power supply operate reliably from unregulated 24 V DC battery backup banks?
A4: Yes. Its wide 18.5 V to 36 V DC input window accommodates deep battery discharge states as well as float-charging voltage spikes while holding output regulation within ±5%.
Q5: What preventive maintenance checks preserve the 80,000-hour MTBF rating in harsh chemical plants?
A5: Inspect cabinet door seals regularly to maintain ISA G3 corrosive gas protection, verify screw terminal torque on the 2.5 mm² DC input lines annually, and keep convection vents free of conductive dust accumulation.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.