1794-IM16 Allen-Bradley Flex I/O 240V AC Digital Input Module
Manufacturer: Allen-Bradley
Product No.: 1794-IM16
Condition: In stock
Product Type: AC Input Module
Payment: T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
1794-IM16 High-Voltage AC Input Interface
The 1794-IM16 is a high-density, 16-channel digital AC input interface belonging to the Allen-Bradley Flex I/O Series engineered by Rockwell Automation. Designed specifically for direct monitoring of 240V AC line-voltage field devices, this module accommodates a nominal operating input range of 159 to 264V AC (47…63 Hz). It utilizes a non-isolated architecture across individual channels with 250V continuous basic insulation between field circuits and the backplane logic (type tested at 1530V AC for 60 seconds). With a nominal input impedance of 22.2 kΩ and an 11 mA input current draw at 240V AC, the unit draws only 32 mA at 5V DC from the Flexbus backplane. The module snaps into 1794-TBN and 1794-TBNK terminal base units set to Keyswitch Position 8, dissipating a maximum of 6 W power (20.47 BTU/hr thermal output) at 264V AC.
Technical Specifications Breakdown
| Manufacturer / Brand | Rockwell Automation / Allen-Bradley |
| Catalog Part Number | 1794-IM16 |
| Product Line | Flex I/O Series |
| Module Function | Digital AC Input Module |
| Input Density | 16 Non-Isolated Inputs (Single Group) |
| Nominal Input Voltage | 240V AC (Operating Envelope: 159…264V AC, 47…63 Hz) |
| On-State Voltage Threshold | 159V AC min / 240V AC nom / 264V AC max |
| On-State Current Draw | 5.30 mA min @ 159V AC / 13.29 mA max @ 264V AC (11 mA nom @ 240V AC) |
| Off-State Thresholds | 40V AC max / 2.6 mA max off-state leakage current |
| Nominal Input Impedance | 22.2 kΩ @ 50/60 Hz |
| Field-to-Backplane Isolation | 250V continuous (Basic Insulation); Type tested @ 1530V AC for 60 seconds |
| Channel-to-Channel Isolation | None (Shared internal AC common line across all 16 channels) |
| Flexbus Power Consumption | 32 mA @ 5V DC |
| Power & Thermal Dissipation | 6 W max @ 264V AC | 20.47 BTU/hr max @ 264V AC |
| Recommended Terminal Bases | 1794-TBN, 1794-TBNK |
| Terminal Base Keyswitch Position | Position 8 |
| Ambient Operating Temperature | 0 to 55 °C (32 to 131 °F) |
| Physical Dimensions & Weight | 94 x 94 x 91 mm (3.7 x 3.7 x 3.6 in.) | 141 g (4.97 oz) |
Target Equipment & Field Integration Scenarios
The high AC voltage threshold of the 1794-IM16 eliminates the need for external step-down control transformers or interposing relay contacts when monitoring 220V/240V machinery lines:
- Direct status monitoring of 230V AC motor starter auxiliary contacts (NO/NC state feedback)
- Interfacing with high-voltage HVAC pressure switches, limit switches, and safety thermostats
- Reading field positions from 240V AC motorized valve actuators in utility systems
- Monitoring power distribution status and main circuit breaker auxiliary trip indication lines
- Processing discrete signals from industrial oven control panels operating on single-phase 240V feeds
Diagnostic Visuals & Channel Isolation Logic
Front-panel diagnostics combined with internal line protection ensure straightforward control cabinet setup:
- Channel Visual Status LED Array: Sixteen individual yellow status LEDs located on the field side illuminate when field input signals exceed the 159V AC ON-state threshold.
- Backplane Optical Isolation: Optocouplers provide 250V continuous basic insulation protecting the sensitive Flexbus backplane electronics from field-side voltage transients up to 1530V AC.
- Common Neutral Bus Design: All 16 channels share an internal AC common connection, optimizing wiring density on 1794-TBN NEMA-style terminal bases.
Packaging, Fast Delivery & Guarantee
- Condition: Brand New, Original Factory Sealed Unit
- Warranty Terms: Covered by a 12 Months Replacement Warranty
- Order Processing: Dispatches within 24–48 hours from order confirmation
- Global Express Logistics: Direct international express transit via FedEx, UPS, or DHL
Global PLC Spare HUB's Insight
The 1794-IM16 is a robust solution for retrofitting legacy European or high-voltage utility control panels that utilize 220V–240V AC control logic. Because all 16 channels share a non-isolated common return bus inside the terminal base, all monitored input devices must be powered from the same AC phase leg or control transformer. Connecting signals from different phase legs (e.g., L1 and L2 of a 3-phase system) across channels on a single module will cause an immediate phase-to-phase short circuit across the internal common rail. If your installation requires monitoring inputs fed from multiple independent power transformers, opt for isolated input modules like the 1794-IA8I instead.
Frequently Asked Questions (FAQ)
Q: What field voltage condition causes the channel status LED to turn off on this 240V AC input module?
A: The input circuitry guarantees an OFF state when the field voltage drops below 40V AC or when the leakage current drops under 2.6 mA; any signal between 40V AC and 159V AC falls into an indeterminate switching zone and must be avoided.
Q: Can field input lines powered from two different 240V AC control transformers be wired to channels on the same base?
A: No; because all 16 channels are non-isolated and share a single internal common line inside the module, all field devices connected to the base must derive their 240V AC power from the exact same control transformer source.
Q: What terminal base units are recommended for installing this 16-point 240V AC input module?
A: Rockwell Automation recommends using the 1794-TBN or 1794-TBNK terminal base units, which provide NEMA-style screw terminals designed specifically to accommodate high-voltage AC field wiring safely.
Q: Why does a long field cable run cause a input channel to register a false ON state even when the field contact is open?
A: High-voltage AC signal wires running in parallel over long distances suffer from capacitive cable coupling, which can induce voltages above the 40V AC OFF-state threshold; installing parallel loading resistors (bleeder resistors) at the input terminals dissipates induced voltages.
Q: Selection Guide: How do I determine whether to specify the 1794-IM16 or the 1794-IA16 for a project?
A: Select the 1794-IM16 when field control devices operate on nominal 220V–240V AC control power (159…264V AC range). Select the 1794-IA16 when field signals operate on standard 120V AC control power (74…132V AC range).
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.