1794-ACNR Redundant ControlNet Media Adapter Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 1794-ACNR
Condition: In stock
Product Type: Adapter Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The 1794-ACNR is a DIN rail-mounted, dual-port ControlNet communication adapter manufactured by Allen-Bradley for the FLEX I/O architecture. Designed to interface local distributed I/O clusters with high-level PLC/PAC host controllers, this redundant media module bridges field-level signals onto high-availability ControlNet coaxial data highways at transmission speeds of 5 Mbps.
Capable of powering and backplane-managing up to 8 FLEX I/O expansion modules, the 1794-ACNR delivers a maximum Flexbus output current of 640 mA @ 5 VDC. Featuring dual BNC connectors for media redundancy (Comm A and Comm B), the adapter ensures uninterrupted deterministic I/O data transfer even in the event of a primary trunk cable severance or physical port failure.
System Architecture & Communication Specs
-
Dual-BNC Redundant Media Interface
- Equipped with two independent BNC coaxial connectors for direct tap-in to redundant ControlNet trunks.
- Automatic media health monitoring and seamless failover between Trunk A and Trunk B without dropping I/O connections.
- Fully compliant with ControlNet Protocol Version 1.25, supporting maximum data rates up to 5 Mbps over RG-6/U coax cable.
-
Flexbus Power & Expansion Capacity
- Drives up to 8 discrete, analog, or specialty FLEX I/O terminal base units per adapter node.
- Provides up to 640 mA backplane current at 5 VDC to power connected I/O logic circuits.
- Galvanically isolated design featuring 850 VDC isolation withstand voltage for transient surge suppression.
-
Power Handling & Thermal Parameters
- Operates off an external 24 VDC nominal supply (19.2 to 31.2 VDC input range, SELV/PELV compliant).
- Maximum power dissipation limited to 4.6 W @ 19.2 VDC with a thermal output of 15.7 BTU/hr.
Technical Specifications
| Part Number | 1794-ACNR |
| Manufacturer & Brand | Allen-Bradley / Rockwell Automation |
| Product Series | FLEX I/O Series |
| Module Type | Redundant ControlNet Communication Adapter |
| Communication Ports | 2 x ControlNet BNC Coaxial Ports (Comm A / Comm B) |
| Data Baud Rate | 5 Mbps Deterministic ControlNet Protocol |
| Maximum Expansion | Up to 8 FLEX I/O Terminal Base Units / Modules |
| Flexbus Output Current | 640 mA Maximum @ 5 VDC |
| Input Power Supply | 24 VDC Nominal (19.2 to 31.2 VDC Range) |
| Inrush Current | 23 A for 2 Milliseconds Maximum |
| Operating Temperature | -20°C to +55°C (-4°F to +131°F) |
| Vibration / Shock Resistance | 5 g @ 10–500 Hz (Operating) / 30 g Shock |
| Mounting Options | 35 mm DIN Rail or Direct Panel Mounting |
| Dimensions & Enclosure | 94 x 91 x 86 mm (3.7 x 3.6 x 3.4 in) | Open Type |
Diagnostic Capabilities & Front Panel Telemetry
- Dual Comm Status LEDs: Independent bi-color (Red/Green) indicators for Comm A and Comm B display network link integrity, packet loss, and channel fault states.
- I/O Status LED: Provides direct visual indication of Flexbus backplane communication, module configuration mismatches, and rack fault conditions.
- ControlNet Network Diagnostics: Accessible via RSLogix / Studio 5000 environment to monitor media noise levels, duplicate node detection, and signal attenuation metrics.
Target Application Scenarios & Automation Systems
- Continuous Process Control: Integrates remote FLEX I/O racks in chemical processing units where network downtime is unacceptable.
- High-Availability PLC Architectures: Interfaced with ControlLogix (1756-CN2R) or PLC-5 ControlNet scanner modules in dual-media configurations.
- Vibration & Harsh Machinery Environments: Rated for 5 g vibration and 30 g operating shock, suitable for heavy industrial skid mounting.
Installation & Power Supply Guidelines
- Power Supply Compliance: Connect strictly to an isolated SELV or PELV 24 VDC power supply to ensure compliance with CE Low Voltage Directives.
- Flexbus Current Budgeting: Calculate total 5 VDC current consumption across all 8 attached modules to ensure the total load does not exceed 640 mA.
- BNC Tap Cable Routing: Maintain proper coaxial cable bending radii and ensure BNC coupling nuts are firmly locked to prevent signal reflection.
Packaging, Logistics & Warranty Terms
- Dispatch Lead Time: Factory-sealed units in stock, ready for dispatch within 24 to 48 hours.
- Global Express Delivery: Priority international shipping provided via FedEx, UPS, and DHL.
- Quality Assurance: Delivered 100% Brand New and Original in sealed manufacturer packaging.
- 12-Month Coverage: Backed by a full 12-month quality replacement warranty against operational defects.
Engineering Procurement Guide
- Verify Coax Trunk Hardware: Ensure BNC taps, trunk terminators (75-ohm), and Belden RG-6/U cables meet ControlNet physical layer installation standards.
- Confirm Node Address Assignment: Ensure the network address switches on the adapter are set correctly prior to mounting on the DIN rail.
- Calculate External Power Supply Capacity: Budget for the 23 A for 2 ms inrush current characteristic during system cold boots.
Frequently Asked Questions (FAQ)
Q: What occurs if Trunk A experiences a physical cable cut while the system is operating?
A: The adapter instantly flags Comm A as faulted and switches communication traffic to Trunk B without dropping backplane I/O connections or halting the process controller.
Q: How do I determine if my 8 attached I/O modules exceed the maximum Flexbus power limit?
A: Sum the 5V Flexbus current requirements listed in the data sheets for all 8 modules; the total must remain below the 640 mA output limit of the adapter.
Q: Can this communication module be installed in an outdoor cabinet without secondary enclosures?
A: No, the adapter features an open-type enclosure rating and must be mounted inside an IP54 or NEMA-rated protective industrial panel.
Q: What is the recommended procedure for setting the ControlNet node address on this device?
A: Use the rotary switches located on the module to select a unique network node number before applying power to the 24 VDC terminals.
Q: Are special grounding considerations required for the BNC network connections?
A: Yes, ControlNet taps must be properly grounded at specified single-point ground locations to prevent shield voltage buildup and signal distortion.
Global PLC Spare HUB's Insight
During an emergency shutdown at an automotive stamping facility, maintenance engineers traced a recurring machine trip to a broken communication head on a remote FLEX I/O rack. The legacy single-media adapter had suffered a physical BNC port fracture from high press vibration, cutting off all I/O telemetry to the main PLC rack.
Our engineering team recommended replacing the damaged unit with the 1794-ACNR dual-port redundant adapter. By wiring dual RG-6/U coaxial cable runs to Comm A and Comm B and securing the assembly onto a reinforced DIN rail, the plant established full media redundancy. When minor cable wear occurred months later on line A, the card transferred communication seamlessly to line B, avoiding an estimated $45,000 in unplanned downtime.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



