XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
Manufacturer: Honeywell
Product No.: XNX-AMSV-RNNNN
Condition: En stock
Product Type: Universal Gas Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 5000g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Overview
The XNX-AMSV-RNNNN Honeywell Universal Transmitter delivers robust, multi-gas sensing coverage engineered specifically for high-temperature and combustible gas detection environments. Built with a painted 316 stainless steel housing, this unit operates as a high-reliability interface for millivolt (mV) sensor inputs, including Sensepoint HT, Model 705, and Multi-Purpose Detector (MPD) assemblies. It integrates directly into safety shutdown loops via dual-output architectures: standard 4-20mA with HART protocol and three fully configurable internal SPCO relays.
Product Architecture & Configuration Breakdown
-
Honeywell XNX Series Platform
- Approval Type [A]: ATEX / IECEx Hazardous Area Certified
- Enclosure Entry [M]: 5 x M25 Threaded Entries
- Housing Material [S]: Marine-grade Painted 316 Stainless Steel
- Sensor Personality [V]: mV Input Interface (Sensepoint HT, Model 705, MPD)
- Hardware Option [R]: 3 x Form "C" SPCO Alarm/Fault Relays Installed
- Local Interface [N]: No Local External HART Port Installed
- Sensor Range [NNN]: Base Transmitter Assembly (Sensor Sold Separately)
Engineering Specifications Matrix
| Technical Parameter | Field Specification Standard |
|---|---|
| Brand & Series | Honeywell XNX Universal Transmitter |
| Full Part Number | XNX-AMSV-RNNNN |
| Input Signal Type | Millivolt (mV) Bridge Signal for Catalytic Bead and IR Sensors |
| Primary Output Signal | 4-20mA Analog Signal with Integrated HART Protocol |
| Secondary Relay Output | 3 Form "C" SPCO Contacts (2 Alarm, 1 Fault) @ 250VAC 5A / 24VDC 5A |
| Measurement Range | 0–100% LEL / Target Sensor Specific |
| Signal Resolution | 0.1% LEL Digital Communication Output |
| Linearity & Response | Linear 4-20mA Output; T90 Response Time Sensor Dependent |
| Noise Immunity (EMC) | EN 50270 Industrial Electromagnetic Compatibility Standard |
| Ingress Protection | IP66 Enclosure Rating (NEMA 4X equivalent) |
| Operating Temperature | -40°C to +65°C (-40°F to +149°F) Base Transmitter Rating |
| Operating Humidity | 0 to 99% RH non-condensing |
| Operating Pressure | 80 kPa to 120 kPa Absolute Pressure |
| Physical Unit Weight | 6.8 Kg (Solid Stainless Steel Housing) |
Compatible Hardware & Field Application Scenarios
-
Compatible Sensor Hardware:
- Sensepoint High Temperature (HT) Combustible Gas Sensors
- Model 705 High-Temperature Catalytic Bead Detectors
- MPD Series Catalytic and Infrared Millivolt Cartridges
-
Target Industrial Applications:
- Turbine enclosures, exhaust ducting, and high-ambient heat zones up to 150°C (via remote HT sensors).
- Offshore FPSOs, drilling rigs, and coastal LNG regasification terminals requiring 316SS corrosion resistance.
- Standalone safety isolation skid systems leveraging direct relay contact interlocks without external PLCs.
Diagnostic & Predictive Monitoring Capabilities
The internal diagnostic engine on the XNX-AMSV-RNNNN Honeywell transmitter actively continuously samples internal supply voltage, memory checksums, sensor loop continuity, and bridge zero stability. In the event of a damaged sensor filament, low voltage condition, or signal drift, the unit instantly forces the 4-20mA signal into a dedicated fault state (≤2.0mA) and drops the dedicated internal Fault Relay contact, allowing control room operators to intercept failures before process safety trip thresholds are breached.
Model Selection Comparison & Engineering Recommendation
Selecting the correct model configuration is critical for long-term field stability. Below is a side-by-side comparison between the XNX-AMSV-RNNNN and the alternative XNX-AMAV-NHNNN transmitter configuration:
| Selection Feature | XNX-AMSV-RNNNN | XNX-AMAV-NHNNN |
|---|---|---|
| Enclosure Material | Painted 316 Stainless Steel (6.8 kg) | Painted LM25 Marine-Grade Aluminum (2.8 kg) |
| Relay Capability | 3 x Mechanical SPCO Relays Included | No Relays Installed (Loop-Powered Only) |
| Local Interface | Standard Housing (No External HART Port) | Integrated Local External HART Port Included |
| Cable Entry Access | 5 x M25 Threaded Entries | 5 x M25 Threaded Entries |
Engineering Advice: Choose the XNX-AMSV-RNNNN for severe corrosive atmospheres (such as marine spray zones or acid vapor exposure) or when local electromechanical interlocks (horns, beacons, automatic valve closures) must be driven directly by the transmitter. Conversely, select the XNX-AMAV-NHNNN if weight reduction is crucial, local hand-held HART technician access is preferred on the unit exterior, and all alarm processing is handled entirely by a central DCS/PLC system.
Global PLC Spare HUB's Insight
During a retrofit commissioning project on a gas turbine enclosure, our automation team encountered persistent signal trip faults on a competitor's transmitter due to high ambient heat radiation breakdown. Replacing the standard assemblies with the XNX-AMSV-RNNNN Honeywell combined with a remote-mounted Sensepoint HT sensor resolved the false tripping completely. The heavy 316 stainless steel casing acts as an excellent thermal buffer, and utilizing the 5th M25 cable gland for auxiliary relay wiring simplified the local shutdown wiring loop significantly without needing an extra junction box.
Warranty, Logistics & Ordering Information
- Product Condition: 100% Brand New and Original Factory Supply
- Warranty Coverage: Comprehensive 12-Month Quality Guarantee from dispatch date
- Order Processing Time: Ships within 24 to 48 hours post-payment verification
- Express Global Logistics: Direct fast shipping via FedEx, UPS, and DHL Express networks
Engineering Selection & Application FAQ
What is the primary advantage of choosing an 'mV' personality transmitter over an Optima interface model?
The 'V' (mV) personality is specifically tailored to process analog bridge resistance signals from high-temperature catalytic beads and MPD sensors, allowing you to monitor harsh areas (up to 150°C) where standard electronic optical transmitters cannot physically survive.
Does this unit include the local external HART socket on the bottom of the housing?
No. The model code designates 'N' under Local HART, meaning it does not feature the external plug-in port. HART protocol remains fully accessible internally across the main 4-20mA field wiring terminals or handheld device interface clips.
Can I use the internal relay contacts to trigger a local beacon and horn directly?
Yes. The 'R' option provides three SPCO contacts rated for 250VAC 5A / 24VDC 5A, allowing direct switching of power to local alarm horns or strobe lights without requiring external interposing relays.
What is the purpose of having 5 x M25 cable entry ports on this enclosure?
Having 5 ports accommodates incoming main power, analog 4-20mA loop signaling, relay output wiring multi-core cables, and direct connections to remote sensors without needing separate external explosion-proof junction boxes.
How do I perform routine zero and span gas calibrations on this transmitter model?
Use the magnetic wand tool on the front glass display glass face to navigate the internal LCD menu. This allows field technicians to execute non-intrusive zero and span adjustments in hazardous zones without opening the flameproof 316SS enclosure.

P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.



