XNX-AMAI-RNIC1 Honeywell XNX Series Transmitter
Manufacturer: Honeywell
Product No.: XNX-AMAI-RNIC1
Condition: En stock
Product Type: Universal Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 4400g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Engineering Overview & Architecture
The XNX-AMAI-RNIC1 engineered by Honeywell represents a high-integrity gas detection transmitter. Built within the XNX Universal Transmitter series, this device integrates onboard relay switching modules for direct local actuator control. Industrial safety engineers deploy this platform to monitor carbon dioxide concentration limits in hazardous processing zones.
Configuration Breakdown & Suffix Architecture
| Configuration Code | Designation Element | Engineering Specification |
|---|---|---|
| XNX | Product Platform | Universal Gas Transmitter Platform |
| A | Approval Certification | ATEX / IECEx certified for explosive atmospheres |
| M | Cable Entry Type | M25 threaded conduit port entries |
| A | Enclosure Material | Epoxy-painted marine-grade aluminium housing |
| I | Personality Interface | Infrared sensor support interface |
| R | Hardware Option | Integrated Relay Output Option installed |
| N | Communication Protocol | Standard 4-20mA loop (No Local HART) |
| IC1 | Sensor Type & Range | Infrared Carbon Dioxide (0 to 5% Vol) sensor module |
Technical Specifications Matrix
- Brand & Model: Honeywell XNX-AMAI-RNIC1
- Measurement Range: 0 to 5% Volume Carbon Dioxide via optics
- Weight Specification: 4.4 kg (9.7 lbs) robust unit mass
- Response Dynamics: Rapid optical diffusion response under 10 seconds
- Signal Output: 4-20mA current source with hardwired relay contacts
- Power Requirements: DC industrial loop power with isolated relay supply
Compatible Field Devices & Application Scenarios
The XNX-AMAI-RNIC1 interfaces smoothly with remote sensor heads including Searchline Excel open-path units and Searchpoint Optima detectors. Typical deployment environments include:
- Enhanced oil recovery plants monitoring high-pressure CO2 injection lines.
- Fermentation vessels in large-scale biochemical manufacturing facilities.
- Underground utility vaults prone to heavy carbon dioxide displacement.
- Offshore drilling modules requiring autonomous relay trip safety actions.
Advanced Diagnostic Capabilities
Continuous internal health monitoring tracks optical window transmittance and lamp intensity degradation. The unit generates proactive fault signals before signal attenuation triggers false safety shutdowns. Instrumentation technicians utilize these diagnostic metrics to schedule cleanings during routine turnaround windows.
Global Logistics, Fulfillment & Warranty
- Expedited Dispatch: Orders process and ship within 24 to 48 hours of confirmation.
- Global Carriers: Secure international transit via FedEx, UPS, and DHL.
- Quality Protection: Backed by a comprehensive 12-month manufacturer defect warranty.
Global PLC Spare HUB's Insight
System designers frequently struggle with loop controller saturation when multiple safety inputs require hardwired emergency interlocks. Field experience reveals that specifying units with onboard relay options like the XNX-AMAI-RNIC1 bypasses central PLC input card bottlenecks. For instance, an ammonia refrigeration plant successfully isolated local ventilation fans directly through the transmitter relay contacts during a minor leak event, preventing system-wide downtime.
Model Selection & Technical Comparison Guide
Evaluating alternative configurations ensures optimal alignment with your plant control architecture. Review the technical comparison below:
| Model Number | Relay Option | HART Protocol | Engineering Recommendation |
|---|---|---|---|
| XNX-AMAI-RNIC1 (Current Model) | Installed (Relay Output) | No Local HART | Optimal for standalone relay interlocking without digital HART infrastructure. |
| XNX-AMAI-NHIC1 | No Relay Option | Local HART Enabled | Recommended for facilities requiring remote digital asset management via HART networks. |
Professional Frequently Asked Questions
Question: How do the integrated relay outputs function during a gas concentration threshold breach on the XNX-AMAI-RNIC1?
Answer: The onboard dry relay contacts change state directly when gas levels exceed pre-set alarm thresholds, enabling immediate auxiliary device actuation without controller delay.
Question: What specific factors should engineers consider when selecting between relay outputs and HART communication models?
Answer: Engineers should choose relay variants when direct local equipment shutdown is required without dependent PLC programming, whereas HART variants suit centralized DCS diagnostics.
Question: Can maintenance personnel perform optical calibration checks without declassifying the hazardous area?
Answer: Yes, the flameproof housing design permits non-intrusive magnetic switch configuration and calibration checks in certified hazardous zones.
Question: Why is infrared sensing preferred over electrochemical cells for 0-5% volume carbon dioxide monitoring?
Answer: Infrared optical absorption technology offers superior resistance to chemical poisoning and exhibits significantly longer operating lifespans in harsh industrial climates.
Question: What preventive measures prevent moisture condensation on the infrared optics inside humid processing plants?
Answer: Ensuring proper M25 cable gland sealing and maintaining continuous enclosure power activates internal thermal management to eliminate internal dew point condensation.

Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.