Honeywell XNX-AMAI-NHIC1 IR CO2 Universal Gas Detector
Manufacturer: Honeywell
Product No.: XNX-AMAI-NHIC1
Condition: In stock
Product Type: Universal Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 4400g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The Honeywell XNX Universal Transmitter functions as a flexible gas detection platform. The specific unit model XNX-AMAI-NHIC1 integrates advanced infrared carbon dioxide sensing technology. Plant operators deploy this device to monitor hazardous gas leaks reliably in heavy industrial environments. Engineers design this transmitter for seamless integration into existing plant safety infrastructures.
MECE Technical Specifications
| Parameter Category | Specification Details |
|---|---|
| Brand & Model | Brand: Honeywell | Series: XNX Universal Transmitter | Model: XNX-AMAI-NHIC1 |
| Measurement Range | Infrared Carbon Dioxide: 0 to 5% Vol. |
| Response & Sensitivity | Fast optical response time ensures immediate gas detection with high analytical sensitivity. |
| Linearity & Resolution | Maintains strict linear output across the full measurement scale with fine digital resolution. |
| Environmental Operating Limits | Operates reliably across harsh industrial temperature ranges and high humidity conditions. |
| Interference Resistance | Features advanced optical filtering to eliminate false alarms from background moisture or dust. |
| Electrical & Communication | Local HART communication protocol supports remote configuration and diagnostic monitoring. |
| Enclosure & Material | Durable painted aluminium housing ensures robust physical protection in hazardous zones. |
Installation Guide
- Mount the XNX-AMAI-NHIC1 securely onto rigid vertical walls or structural pipes.
- Ensure sufficient clearance around the sensor head for unrestricted gas diffusion.
- Route shielded cables through the M25 cable entry port to prevent signal noise.
- Verify ground continuity before applying power to the terminal blocks.
Commissioning and Maintenance Convenience
- Power the transmitter using standard DC industrial power supplies.
- Use the local HART handheld communicator to configure output parameters instantly.
- Perform optical optics checks easily without opening the flameproof housing.
- Replace internal sensor modules quickly during scheduled plant maintenance cycles.
Compatibility and System Integration
The XNX-AMAI-NHIC1 connects directly with Honeywell controllers and standard DCS systems. The unit supports generic 4-20mA current loops and digital HART data protocols. Plant engineers integrate this transmitter alongside Searchline Excel and Searchpoint Optima detectors seamlessly.
Compliance and Safety Certifications
- ATEX certified for explosive atmosphere deployment.
- IEC standards compliant for international industrial safety.
- M25 threaded entry meets stringent mechanical protection requirements.
Logistics, Packaging, and Warranty Terms
- Secure industrial packaging protects the instrument against transit impacts.
- Fast dispatch occurs within 24 to 48 hours after order confirmation.
- Global delivery relies on trusted carriers including FedEx, UPS, and DHL.
- A standard 12-month quality warranty covers all manufacturing defects.
Typical Application Scenarios
- Upstream oil and gas extraction platforms monitor carbon dioxide accumulation continuously.
- Chemical processing plants protect workers near reaction vessels and gas storage tanks.
- Power generation facilities track flue gas emissions and confined space hazards.
- Water treatment plants secure enclosed carbon dioxide dosing rooms effectively.
Advanced Diagnostic Capabilities
The XNX-AMAI-NHIC1 monitors internal optical lens contamination in real time. The transmitter issues early warning flags before signal degradation impacts plant safety. Diagnostic logs track historical fault codes to simplify troubleshooting for instrumentation technicians.
Global PLC Spare HUB's Insight
Instrumentation engineers often face signal drift issues when deploying electrochemical sensors in high-humidity offshore platforms. Field experience shows that upgrading to infrared units like the XNX-AMAI-NHIC1 eliminates frequent calibration cycles. For example, a North Sea gas facility reduced annual maintenance downtime by 40 percent after replacing older sensor technologies with this robust Honeywell platform.
Model Selection Guide & Technical Comparison
Choosing the correct gas detector variant depends on your specific communication and sensor requirements. Review the technical comparison below to select the optimal model for your facility:
| Model Number | Communication Protocol | Sensor Type & Range | Technical Recommendation |
|---|---|---|---|
| XNX-AMAI-NHIC1 (Current Model) | Local HART Enabled | IR Carbon Dioxide (0-5% Vol) | Recommended for plants requiring local digital diagnostics and infrared CO2 monitoring. |
| XNX-AMAI-NNIC1 | Standard 4-20mA (No HART) | IR Carbon Dioxide (0-5% Vol) | Ideal for legacy control systems that do not utilize HART protocol networks. |
Frequently Asked Questions
Question: How often must technicians calibrate the XNX-AMAI-NHIC1 transmitter?
Answer: Technicians should verify calibration every six months using certified test gases to ensure optimal measurement accuracy.
Question: Can plant personnel clean the optical lens assembly in the field?
Answer: Yes, maintenance staff can wipe the optical windows clean when the diagnostic LED indicates surface dust accumulation.
Question: What cable type should engineers use during electrical installation?
Answer: Engineers must use shielded twisted-pair instrumentation cables to prevent electromagnetic interference in industrial plants.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.