Inicio VBS01-CJC Singular AI03 AI04 RTD Thermocouple Terminal Base

VBS01-CJC Singular AI03 AI04 RTD Thermocouple Terminal Base

  • Manufacturer: ABB

  • Product No.: VBS01-CJC

  • Condition: En stock

  • Product Type: Terminal Base

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Product Overview

The Singular VBS01-CJC is a full-size mounting base for HN800 analog input systems. It supports the AI03 8-channel RTD and AI04 16-channel TC/mV modules.

This base integrates a built-in RTD temperature sensor for cold junction compensation (CJC). It provides reliable temperature reference measurement for thermocouple applications.

Two 16-point headers support direct field wiring or remote marshaling connections. Engineers can use pluggable terminal blocks or SPK0x_-yy marshaling cables. This arrangement simplifies field wiring and cabinet termination.

  • Primary function: Mounting and field termination for analog input modules.
  • Supported signals: RTD, thermocouple, and millivolt inputs.
  • Channel capacity: 8 RTD channels or 16 TC/mV channels.
  • CJC function: Integrated RTD temperature reference.
  • Mounting method: 35 mm DIN rail installation.
  • System architecture: Singular HN800 I/O configuration.

Technical Specifications

Parameter Specification
Brand Singular
Model VBS01-CJC
Product Type Analog Input Module Mounting Base
System HN800 I/O Bus
Configuration Singular
Supported Modules AI03 and AI04
Channel Capacity 8 RTD or 16 TC/mV channels
Built-in Sensor RTD for Cold Junction Compensation
Signal Connections 2 × Pluggable 16-point Terminal Blocks
Alternative Connection SPK0x_-yy Marshaling Cables
Mounting 35 mm DIN Rail
Mounting Orientation Vertical Column
Form Factor Full Size
Dimensions 218 × 67.5 × 114 mm (H × W × D)
Weight 327 g
Hot-Swap Support No
Field Power Connection Compact
Field Power Fusing Not Applicable
Maximum Current HBX01L/HBX01R pair: 3.0 A maximum at +24 VDC
Field Wire Size #22–14 AWG stranded or solid; #12 AWG stranded
Galvanic Isolation Test 1500 V for up to 1 minute
Overvoltage Category Category I for power
HN800 Bus Length 305 mm
MTBF 8,015,104 hours (MIL-HDBK-217-FN2)
MTTR 8 hours
Protection Rating IP20

Environmental and Electrical Performance

The VBS01-CJC supports industrial control cabinet environments. Its specifications address temperature variation, mechanical stress, and electromagnetic interference.

Environmental Parameter Rated Performance
Operating Temperature -40 to +70 °C
Storage Temperature -40 to +85 °C
Relative Humidity 20%–95% at 40 °C, non-condensing
Operational Vibration 5–60 Hz: 0.137 mm; 60–150 Hz: 1.0 G
Transportation Vibration 10–500 Hz
Storage Shock 15 G, 11 ms
Drop Resistance Test 100 mm
Operating Altitude Sea level to 3,048 m
Storage Altitude Sea level to 12,192 m
Air Quality ISA S71.04 G1

Electromagnetic Compatibility:

  • ESD immunity: IEC/EN 61000-4-2, Severity Level 3.
  • Surge immunity: IEC/EN 61000-4-5, Severity Level 3.
  • Electrical fast transient: IEC/EN 61000-4-4, Severity Level 3.
  • Radiated RFI immunity: IEC/EN 61000-4-3, Severity Level 3.
  • Conducted immunity: IEC/EN 61000-4-6, Severity Level 3.
  • Magnetic field immunity: IEC/EN 61000-4-8, Severity Level 4.
  • Voltage dips and interruptions: IEC/EN 61000-4-11.
  • Emission limits: CISPR 11, Group 1, Class A.

Important measurement note: The mounting base provides signal termination and CJC reference support. Measurement range, frequency response, sensitivity, linearity, and resolution depend on the installed AI03 or AI04 module. Consult the corresponding module datasheet before finalizing measurement configurations.

Installation Guide

  1. Verify the hardware: Confirm the base model and supported AI03 or AI04 module.
  2. Prepare the cabinet: Install a standard 35 mm DIN rail.
  3. Mount the base: Align the VBS01-CJC with the DIN rail and engage its latching mechanism.
  4. Check alignment: Ensure the base sits securely in its vertical mounting position.
  5. Connect field signals: Use the two 16-point headers and compatible terminal blocks.
  6. Configure marshaling: Use SPK0x_-yy cables when field signals terminate on third-party hardware.
  7. Install the I/O module: Confirm the correct module type and mechanical keying.
  8. Inspect wiring: Verify terminal assignments, polarity, and grounding arrangements.
  9. Complete commissioning: Check signal continuity and CJC operation before process startup.

Safety precaution: Isolate relevant field circuits before installation or wiring changes. This base does not support hot swapping.

Commissioning and Maintenance

Proper commissioning helps maintain reliable temperature measurements and stable analog input connections.

  • CJC verification: Check the integrated RTD reference during thermocouple commissioning.
  • Channel validation: Confirm each RTD, TC, or mV channel against the control system configuration.
  • Wiring inspection: Check terminal tightness and field cable identification.
  • Signal troubleshooting: Inspect terminal connections before replacing the I/O module.
  • Mechanical inspection: Confirm DIN-rail engagement and base latching.
  • Environmental checks: Keep the installation within specified temperature and humidity limits.
  • Maintenance planning: Include terminal inspection in routine cabinet maintenance.

Always isolate power before removing modules or changing field wiring. Record terminal assignments before performing maintenance.

Compatibility and Configuration Notes

Item Compatibility Information
AI03 Supported; 8-channel RTD analog input module
AI04 Supported; 16-channel TC and mV analog input module
HN800 Bus Designed for Singular HN800 I/O configurations
Terminal Blocks Two pluggable 16-point terminal blocks
Marshaling Cables SPK0x_-yy cable family
Mechanical Keying Optional keying prevents incorrect module insertion

System integration advantage: Singular and Redundant I/O bases and modules support a common HN800 I/O bus architecture. Compact and Full-size variants also share system compatibility.

However, VBS01-CJC itself is a Singular, Full-size mounting base. Its listed module support remains AI03 and AI04. Confirm the specific base, bus, and module configuration before ordering.

The standard version meets ISA S71.04 G1 air-quality requirements. The VBS01-CJCA variant is available for G3-compliant environments. Verify the required suffix when selecting equipment for corrosive industrial atmospheres.

Certifications and Compliance

  • CSA: Certified for ordinary, non-hazardous locations.
  • CSA Class I, Division 2: Groups A, B, C, and D nonincendive locations.
  • CE: EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC.
  • RoHS: Directive 2015/863.
  • WEEE: Directive 2012/19/EU.
  • Electrical safety: Tested according to IEC/EN 61010-1.
  • Environmental testing: IEC/EN 60068 and MIL-STD-810G, as applicable.

Certification requirements may depend on the installation configuration and applicable regulations. Verify the product documentation before deployment.

Package Contents

  • 1 × Singular VBS01-CJC Analog Input Mounting Base
  • Terminal blocks, marshaling cables, and I/O modules are not included unless specified in the order.
  • Additional accessories depend on the confirmed purchasing configuration.

Frequently Asked Questions (FAQ)

Q1: What is the primary function of the VBS01-CJC mounting base?

The VBS01-CJC provides mechanical mounting and field signal termination for AI03 and AI04 modules. It also integrates an RTD reference for thermocouple cold junction compensation.

Q2: Can the VBS01-CJC support both RTD and thermocouple applications?

Yes. It supports up to eight 2-, 3-, or 4-wire RTDs with AI03. It also supports sixteen TC or mV signals with AI04.

Q3: Does the integrated RTD replace an external cold junction compensation sensor?

The built-in RTD provides the CJC reference for supported thermocouple configurations. Confirm the AI04 configuration and system engineering requirements before adding external compensation hardware.

Q4: Can engineers replace the I/O module while the system remains powered?

No. The published specification identifies VBS01-CJC as non-hot-swappable. Isolate the relevant power and field circuits before module replacement.

Q5: What should engineers check when thermocouple readings show unexpected temperature deviations?

First, inspect thermocouple polarity and terminal connections. Then verify the AI04 channel configuration and CJC reference. Also check cabinet temperature stability and field wiring integrity.

Q6: Can the VBS01-CJC connect to third-party termination hardware?

Yes. Compatible SPK0x_-yy marshaling cables support connections to third-party termination hardware. Verify the exact cable configuration and terminal assignment before installation.

Q7: Can Singular and Redundant I/O modules share one HN800 bus?

The system architecture supports compatibility across Singular and Redundant, Compact and Full-size I/O products. However, engineers must verify each base and module's individual configuration requirements.

Q8: Which version should engineers select for corrosive environments?

The standard VBS01-CJC meets ISA S71.04 G1 air-quality requirements. Consider VBS01-CJCA when the application requires ISA S71.04 G3 compliance. Confirm the actual site classification before ordering.

Q9: What is the most important check before replacing an existing mounting base?

Verify the exact model, supported I/O module, bus architecture, mounting dimensions, and terminal arrangement. A matching channel count alone does not guarantee electrical or mechanical compatibility.

Q10: What information should buyers provide when requesting a quotation?

Provide the VBS01-CJC model number, required quantity, installed AI03 or AI04 module, and target HN800 configuration. Include environmental requirements when selecting the G1 or G3 version. These details help reduce ordering errors and commissioning delays.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.