Inicio T77610-10 AI-Tek Instruments Tachtrol 10 Overspeed Protection

T77610-10 AI-Tek Instruments Tachtrol 10 Overspeed Protection

  • Manufacturer: AI-TEK

  • Product No.: T77610-10

  • Condition: En stock

  • Product Type: Overspeed Protection

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

AI-Tek Instruments T77610-10 Tachtrol 10 – Multifunction Speed Monitoring and Protection

The AI-Tek Instruments T77610-10 Tachtrol 10 is a multifunction tachometer and speed-monitoring instrument. It processes speed-related signals from two input channels and supports a broad range of monitoring, alarm, transmission and control applications.

Its measurement functions include overspeed shutdown, bidirectional speed measurement, reverse-rotation detection, low-speed monitoring and frequency measurement. Configurable relay and analog outputs support integration with machine protection systems, control panels and process instrumentation.

01 | Measurement Capabilities

Function Engineering Application
Overspeed Monitoring Fast-response overspeed shutdown and alarm functions
Dual-Channel Measurement Two-channel speed or draw monitoring
Direction Detection Bidirectional tachometer and reverse-rotation alarm
Low-Speed Monitoring Low-speed tachometer applications
Mechanical Monitoring Clutch slip alarm and winder control
Marine Measurement Ahead/astern tachometer applications
Signal Conversion Expanded analog scale speed transmission and computer signal conditioning
Process Measurement Flow rate, process time and time-per-event monitoring
Specialized Measurement Autoranging, averaging and line-frequency tachometer functions
Frequency Monitoring 60.00 Hz and 400.0 Hz line-frequency monitoring
Remote Transmission RS485 speed transmission

02 | Input Signal and Measurement Limits

The Channel A and Channel B inputs accept square-wave or sinusoidal signals. Their wide frequency range supports both slow rotational processes and higher-speed monitoring.

Parameter Specification
Input Channels Channel A and Channel B
Frequency Upper Limit 50 kHz absolute maximum; 40 kHz typical
Frequency Lower Limit 0.005 Hz absolute minimum; 0.05 Hz typical
Minimum Pulse Width 0.5 µs
Supported Waveforms Square wave and sinusoidal
Input Impedance 12 kΩ typical
Maximum Input Voltage ±30 V AC or DC
Adjustable Logic Thresholds 200 mV to +28 V, approximately 20 mV steps, ±3%
Minimum Input Sensitivity 200 mV peak, absolute minimum
Common-Mode Rejection Greater than 40 dB at 1 kHz, typical

Channel isolation: Channels A, B and Direction share a common ground. Each signal group provides 500 Vrms isolation to the output and to ground, as specified.

03 | Power Architecture

Power Parameter Specification
DC Supply 12–30 VDC
AC Supply 80–264 VAC, 50–60 Hz
Reverse Polarity Protection Provided on DC input
Typical Consumption 3.5 W for tachometer only
Remote Display Allowance Add 0.5 W per remote display
12 V Output Allowance Add 2.0 W
Maximum Power Consumption 9.5 W
Auxiliary Output Regulated 12 V at 150 mA with input voltage of 13.6 V or higher
Low-Voltage Output Behavior Below 13.6 V input, output is approximately input voltage minus 1.5 V

Dual-source behavior: When AC and DC supplies are both connected, the instrument loads the DC source above approximately 15 VDC. Below this level, it loads the AC source.

04 | Output Performance and Control Interfaces

The Tachtrol 10 supports relay switching, analog signal transmission and serial communication. These interfaces allow measured speed information to reach protection logic, PLCs, control systems and supervisory equipment.

Output Interface Technical Characteristics
Mechanical Relay Form C contacts
Mechanical Contact Rating 10 A at 125/250 VAC; 6 A at 277 VAC; 5 A at 30 VDC; 0.5 A at 100 VDC
Mechanical Switching Capacity 2500 VA
Mechanical Relay Response 16.5 ms maximum input-to-output; 10 ms relay-only response
Mechanical Relay Isolation 1500 Vrms, 1 minute, coil to contacts
Solid-State Relay Form A; 400 mA at 60 V AC or DC
Solid-State On Resistance 2 Ω maximum
Solid-State Response Operate: 2 ms maximum, 0.8 ms typical; release: 0.5 ms maximum, 0.1 ms typical
Solid-State Isolation 500 Vrms, 1 minute
Alarm Setpoint Accuracy ±0.005% internal instrument accuracy

05 | Analog Transmission and Digital Communication

Analog Output Parameter Specification
Selectable Ranges 0–20 mA, 4–20 mA and -20–0–+20 mA
Internal Instrument Accuracy ±0.005%
Room-Temperature Accuracy ±0.05% of full-scale range with 400 Ω load, in addition to internal accuracy
Accuracy Over Temperature and Load Range ±0.1%
Resolution 16-bit D/A; 610 nA per LSB
Linearity ±0.02% typical
Loop Impedance 100–1000 Ω
Response Time 6.55 ms plus 1 ms settling at 1 kΩ, worst case, to 0.1% of final value
Electrical Isolation 500 Vrms continuous
Calibration Factory calibrated; recalibration supported through TACHLINK

RS485 communication: The serial interface operates at 19.2 kbaud using an 8-N-1, half-duplex protocol. The tachometer acts as the bus master.

06 | Display and Operator Interface

Display Parameter Specification
Applicable Display Versions TT and TTplus
Display Type Black-and-white graphics display
Pixel Resolution 64 × 128 pixels
Display Accuracy ±0.05% of full scale

07 | Additional Control Inputs

Verify and Reset inputs support external control signals. Their characteristics differ from the primary speed-measurement channels.

Parameter Verify and Reset Direction
Signal Frequency Essentially DC Essentially DC
Minimum Pulse Width 250 µs 0.5 µs
Input Impedance 10 mA current regulated 12 kΩ typical
Input Sensitivity 3.5 V minimum pulse to ground ±30 V AC or DC maximum
Logic Threshold Not specified in supplied data Adjustable from 0 to 28 V in approximately 20 mV steps, ±3%
Common-Mode Rejection Greater than 40 dB at DC, typical Greater than 40 dB at 1 kHz, typical
Electrical Isolation 500 Vrms signal-to-signal and signal-to-ground 500 Vrms to output and ground

08 | Engineering Integration and Commissioning

  • Confirm the sensor signal: Check waveform, amplitude, frequency range and minimum pulse width before connecting Channel A or B.
  • Set input thresholds: Adjust logic thresholds to match the connected sensor and prevent false pulse detection.
  • Verify direction logic: Confirm the phase or direction signal arrangement before enabling reverse-rotation alarms.
  • Configure alarm outputs: Check relay contact type, load voltage and current against the connected shutdown or control circuit.
  • Scale the analog output: Match the selected current range and engineering-unit span to the receiving PLC or control system.
  • Check RS485 settings: Confirm baud rate, 8-N-1 framing, half-duplex wiring and bus-master arrangement.
  • Validate protection response: Test alarm and trip behavior under controlled conditions before placing the machine into service.

09 | Typical Industrial Applications

  • Rotating machinery overspeed detection and shutdown systems
  • Motor, turbine and shaft speed monitoring
  • Marine propulsion speed and ahead/astern indication
  • Winder, draw-control and clutch-slip monitoring
  • Reverse-rotation and low-speed alarms
  • Process flow, event timing and frequency measurement
  • Analog speed transmission to PLC and DCS platforms
  • Computer-based monitoring and RS485-connected instrumentation

10 | Purchasing and Configuration Notes

Before ordering the T77610-10, confirm the required display version, relay type, analog output range, communication interface and auxiliary power requirements. The published characteristics describe available instrument functions; the exact supplied hardware configuration should be checked against the complete order code.

  • Product: AI-Tek Instruments Tachtrol 10
  • Model: T77610-10
  • Product category: Multifunction tachometer and speed-monitoring instrument
  • Primary functions: Speed measurement, overspeed protection, alarm switching and signal transmission
  • Communication: RS485, 19.2 kbaud

Frequently Asked Questions

Q1: What should be checked when a speed reading fluctuates even though the machine runs steadily?

Start by checking sensor mounting, cable shielding, grounding and signal amplitude. Then inspect the input waveform for noise or missing pulses. A threshold setting that does not match the sensor output can also cause unstable readings.

Q2: How should the T77610-10 be evaluated for a safety-related overspeed trip?

Review the complete shutdown architecture, not only the instrument response specification. Confirm the configured relay output, external trip circuit, failure response and required safety integrity. Do not assume that the tachometer alone provides a certified safety function.

Q3: What is the practical difference between mechanical and solid-state relay outputs?

Mechanical relays support higher listed contact loads and Form C switching. Solid-state outputs switch faster and have no mechanical contacts, but their current, voltage and load characteristics must match the application.

Q4: What information is needed before replacing an existing Tachtrol 10 unit?

Record the full model and order code, supply arrangement, sensor type, input wiring, relay configuration, analog scaling and communication settings. Also document the existing alarm thresholds and direction logic. Matching the model number alone may not reproduce the original installation.

Q5: How can an engineer confirm whether the analog output is suitable for a long cable run?

Calculate the total loop resistance, including cable and receiver input resistance. Keep the total within the specified 100–1000 Ω range, and check grounding and isolation requirements. Test the current at several points across the configured measurement span before commissioning.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.