Inicio UP55A-002-11-00 Yokogawa UP55A Program Controller Ethernet

UP55A-002-11-00 Yokogawa UP55A Program Controller Ethernet

  • Manufacturer: Yokogawa

  • Product No.: UP55A-002-11-00

  • Condition: En stock

  • Product Type: Controller Ethernet

  • Product Origin: JP

  • Payment: T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Yokogawa UP55A-002-11-00 | Ethernet Program Controller

The Yokogawa UP55A-002-11-00 is a programmable process controller from the UTAdvanced UP55A series. It combines temperature measurement, programmable setpoint control, PID regulation, event monitoring, and industrial communication.

This configuration features standard control, Ethernet communication with a serial gateway function, English display language, and a black front-panel case.

The controller accepts thermocouple, RTD, DC voltage, and DC current signals through its configurable universal input architecture. It supports relay, current, and voltage-pulse control output configurations, depending on the selected hardware specification.

Engineers can integrate this controller into thermal processing equipment, industrial ovens, environmental test chambers, manufacturing machinery, and automated process systems.

01 | Product Identification

Parameter Specification
Manufacturer Yokogawa Electric Corporation
Model Number UP55A-002-11-00
Product Series UTAdvanced UP55A
Product Type Programmable Process Controller
Control Architecture Standard Type
Control Method PID and programmable process control
Network Interface Ethernet with serial gateway function
Display Language English
Case Color Black / Light Charcoal Gray
Fixed Code 00
Weight 0.5 kg maximum

02 | Model and Suffix Configuration Breakdown

The complete ordering code identifies the controller architecture and communication configuration.

Code Segment Configuration Engineering Description
UP55A Product Model UTAdvanced program controller
0 Basic Control Standard type
0 Functions No additional function selected
2 Open Networks Ethernet communication with serial gateway
1 Display Language English default setting
1 Case Color Black / Light Charcoal Gray
00 Fixed Code Standard fixed code

Complete Configuration:

  • UP55A: Programmable controller platform.
  • -0: Standard control architecture.
  • 0: No additional function selected.
  • 2: Ethernet communication with serial gateway.
  • 1: English display language.
  • 1: Black case configuration.
  • -00: Standard fixed code.

Ordering Note: The model suffix identifies the main configuration. Confirm terminal assignments and output hardware before replacing an existing controller.

03 | Universal Input and Measurement Performance

The input architecture supports several industrial sensor and transmitter signal types. Correct input configuration ensures reliable process measurement.

Technical Parameter Specification
Input Types TC, RTD, mV, V, and mA
TC / mV Source Resistance 250 Ω maximum
TC / mV Resistance Effect 0.1 µV/Ω or less
DC Voltage Source Resistance 2 kΩ maximum
DC Voltage Resistance Effect Approximately 0.01%/100 Ω
RTD Wiring Resistance 150 Ω maximum per wire
RTD Wiring Resistance Effect ±0.1 °C/10 Ω
TC / mV / mA / RTD Allowable Input ±10 V DC
Voltage Input Limit ±20 V DC
Current Input Limit ±40 mA
Reference Junction Compensation ±1.0 °C from 15 °C to 35 °C
Extended Compensation Range ±1.5 °C from -10 °C to 15 °C and 35 °C to 50 °C
Applicable Sensor Standards JIS / IEC / DIN, ITS-90

Signal Input Engineering Notes:

  • Maintain equal conductor resistance across all three RTD wires.
  • Use shielded thermocouple wiring in electrically noisy environments.
  • Check transmitter grounding before connecting DC voltage inputs.
  • Verify the selected sensor type and measurement range during commissioning.

04 | Contact Input and Operating Commands

Contact inputs receive external operating commands and switching signals. They support machine coordination and programmable event handling.

Parameter Specification
Input Types Voltage-free contact or transistor contact
Contact Rating 12 V DC, 10 mA or more
Minimum Contact ON Current 1 mA or less
Voltage-Free Contact ON Contact resistance ≤1 kΩ
Voltage-Free Contact OFF Contact resistance ≥50 kΩ
Transistor Contact ON Input voltage ≤2 V
Transistor Contact OFF Leakage current ≤100 µA
Minimum Status Hold Time Control period +50 ms

Typical Input Applications:

  • Program pattern selection.
  • Operation mode switching.
  • External operating commands.
  • Event triggering and machine interlocking.

The available contact input count depends on the hardware and terminal configuration. Check the applicable model code before assigning field signals.

05 | Control Output and Actuator Interface

The UP55A platform supports multiple control output architectures. The selected output type determines the appropriate actuator interface.

Output Type Electrical Characteristics
Current Output 4–20 mA DC or 0–20 mA DC
Current Load Resistance 600 Ω maximum
Current Output Accuracy ±0.1% of span
Low-Range Accuracy ±5% of span for outputs of 1 mA or less
Voltage Pulse ON 12 V or more
Voltage Pulse Load 600 Ω or more
Voltage Pulse OFF 0.1 V DC or less
Pulse Time Resolution 10 ms or 0.1% of output, whichever is larger

Available Control Applications:

  • Continuous PID control using current output.
  • Time-proportional PID control using voltage pulses.
  • Relay-based time-proportional control.
  • Heating and cooling control on applicable configurations.

Output accuracy applies under standard conditions: 23 ±2 °C, 55 ±10% RH, and 50/60 Hz power frequency.

06 | Relay and Transistor Contact Outputs

Relay and transistor outputs support external equipment commands, alarms, and process event signals. Their electrical ratings determine the permitted load interface.

Output Parameter Specification
Control Relay 1c contact, 1 point
Cooling Control Relay 1c contact, 1 point on applicable heating/cooling configurations
Event Relay 1a contact, 3 points
Control Relay Rating 250 V AC, 3 A or 30 V DC, 3 A
Event Relay Rating 240 V AC, 1 A or 30 V DC, 1 A
Transistor Output Open collector, sink current
Transistor Rating 24 V DC maximum, 50 mA
Transistor Output Resolution 100 ms minimum

Application Functions:

  • Process event indication.
  • High and low alarm signaling.
  • Controller FAIL status indication.
  • Time-proportional actuator switching.
  • External sequence control.

Load Requirements: Use control relay outputs with loads of at least 10 mA. Use alarm outputs with loads of at least 1 mA.

07 | Retransmission and Auxiliary Loop Power

The retransmission output transfers a selected controller variable to an external monitoring device. The output shares its terminal resource with the 15 V DC loop power supply.

Parameter Specification
Retransmission Channels 1
Output Signals 4–20 mA DC or 0–20 mA DC
Maximum Load Resistance 600 Ω
Conversion Accuracy ±0.1% of span
Low-Range Accuracy ±5% of span for 1 mA or less
Loop Power Supply 14.5–18.0 V DC
Maximum Supply Current Approximately 21 mA
Protection Short-circuit current limiting

The retransmission function can transmit selected process variables, such as PV, SP, and OUT, subject to configuration.

Important: Retransmission output and 15 V DC loop power share resources. Confirm the required function before wiring an external transmitter.

08 | Position Proportional Control

The UP55A family also supports position-proportional control on the corresponding model configuration. This function requires the appropriate hardware and control architecture.

Parameter Specification
Slide Resistance Input 100 Ω to 2.5 kΩ total resistance
Current Position Input 4–20 mA
Disconnection Detection 100% side and slide line
Sampling Period 50 ms
Measurement Resolution 0.1% of input span
Position Relay Output 1a contact, 2 points
Relay Rating 250 V AC, 3 A or 30 V DC, 3 A

Configuration Warning: UP55A-002-11-00 specifies standard control, not the position-proportional model type. Do not assume this function is enabled on the supplied unit.

09 | Ethernet Communication and Serial Gateway

The selected network code provides Ethernet communication with a serial gateway function. This architecture supports integration between supervisory systems and compatible serial controllers.

  • Communication Interface: Ethernet.
  • Network Protocol: Modbus/TCP.
  • Ethernet Standard: IEEE 802.3.
  • Transmission Speed: 10BASE-T / 100BASE-TX.
  • Gateway Function: Ethernet-to-RS-485 serial communication.
  • Serial Protocol: Modbus/RTU, subject to configuration.

Typical Network Architecture:

  • Host computer or SCADA system connects through an Ethernet switch.
  • UP55A controllers communicate through the Ethernet network.
  • The serial gateway connects compatible RS-485 devices.
  • Additional controllers can share the serial communication network.

For Ethernet wiring, the documented hub-to-controller distance is within 100 m. The serial gateway supports up to 31 connected slaves and a maximum communication cable length of 1,200 m under specified network conditions.

Integration Note: Configure IP addresses, subnet masks, gateway settings, and communication parameters before connecting the controller to the plant network.

10 | Response Time and Noise Immunity

Signal filtering and electrical noise rejection help maintain reliable measurements in industrial environments.

Performance Parameter Specification
Normal Mode Noise Rejection 40 dB minimum at 50/60 Hz
Common Mode Noise Rejection 120 dB minimum at 50/60 Hz
Step Response Within 500 ms at 100 ms control period
Step Response Within 1 s at 200 ms control period
Response Measurement 63% of analog output response for a 10–90% input-span step

Power Frequency Configuration:

  • For 100–240 V AC, select manual setting or automatic detection.
  • For 24 V AC/DC, set the power frequency manually.
  • Match the setting with the actual installation environment.

11 | Installation and Commissioning Guide

Correct panel installation and signal wiring help prevent measurement instability and output faults.

  1. Panel Preparation: Verify the mounting cutout and enclosure clearance against the official dimensional drawing.
  2. Power Verification: Confirm the controller's supply voltage and terminal configuration.
  3. Sensor Wiring: Connect TC, RTD, voltage, or current signals according to the selected input type.
  4. RTD Inspection: Check three-wire resistance balance before enabling measurement.
  5. Output Verification: Match the control output type with the connected actuator.
  6. Communication Setup: Configure Ethernet addressing and gateway parameters.
  7. Parameter Setup: Set input range, control period, PID parameters, and program patterns.
  8. Functional Testing: Verify PV indication, output response, alarms, and communication status.

Commissioning Recommendation: Test the controller with disconnected or simulated field signals before connecting critical actuators. Verify interlocks and alarm responses independently.

12 | Maintenance and Troubleshooting Considerations

Observed Condition Recommended Inspection
Unstable PV Reading Check sensor wiring, shielding, grounding, and input configuration.
RTD Measurement Deviation Inspect three-wire resistance balance and terminal connections.
Incorrect Analog Output Verify output range, load resistance, and scaling parameters.
Relay Chattering Review control parameters, contact load, and process fluctuations.
Ethernet Communication Failure Check IP settings, network cable, switch port, and protocol configuration.
Serial Gateway Failure Inspect RS-485 polarity, termination, slave addresses, and baud rate.
Unexpected Alarm Status Review event thresholds, alarm logic, and external input states.

13 | Compatibility and Replacement Considerations

  • Sensor Compatibility: Confirm the existing TC, RTD, mV, V, or mA input configuration.
  • Control Compatibility: Match relay, voltage-pulse, or current output requirements.
  • Communication Compatibility: Confirm Ethernet and serial gateway requirements.
  • Power Compatibility: Verify supply voltage before installation.
  • Panel Compatibility: Check dimensions, terminal arrangement, and wiring clearance.
  • Program Compatibility: Verify pattern settings, PID parameters, and event assignments.

Do not select a replacement by front-panel appearance alone. Compare the complete model code, optional suffixes, terminal wiring, and application parameters.

14 | Standards and Compliance

  • Thermocouple Standards: JIS, IEC, and DIN based on ITS-90.
  • RTD Standards: JIS, IEC, and DIN based on ITS-90.
  • Communication: IEEE 802.3 Ethernet interface.
  • Product Documentation: Refer to the applicable Yokogawa UP55A technical documentation.

Confirm the required regional approvals and compliance documents against the exact product identification and delivery configuration.

15 | Package Contents

  • 1 × Yokogawa UP55A-002-11-00 Program Controller.
  • Standard product configuration according to the specified model code.

External sensors, communication cables, mounting accessories, and additional wiring components are not included unless specified in the purchase order.

16 | Frequently Asked Questions

Q1: Can the UP55A store multiple temperature profiles for different production recipes?

Yes. The UP55A supports programmable pattern control. The standard platform supports up to 30 program patterns and 300 segments. The /AP option changes the available program capacity. Confirm the installed option before planning recipe storage.

Q2: Can engineers transfer an existing UP55A configuration to a replacement controller?

They can reproduce the configuration after checking the original parameter settings. Record input types, PID values, program segments, alarm thresholds, and communication settings. Verify optional hardware before restoring the configuration.

Q3: What should engineers check when an Ethernet-connected controller remains unreachable?

First, verify the controller IP address and subnet mask. Then inspect the Ethernet link indicators and switch port. Check Modbus/TCP settings and network addressing for duplicate IP conflicts. Test serial gateway communication separately.

Q4: Is a retransmission output suitable for sending process values to a separate recorder?

Yes. The configurable 0–20 mA or 4–20 mA retransmission output can transfer selected process variables. Check the recorder input range and loop resistance. Remember that the retransmission output shares resources with the 15 V DC loop supply.

Q5: What information should procurement provide when sourcing this exact controller?

Provide the complete UP55A-002-11-00 model number and a photograph of the existing nameplate. Include the supply voltage, sensor type, output requirements, communication architecture, and terminal wiring. These details help prevent configuration mismatches during replacement.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.