Inicio GE IS200EGDMH1AAB Mark VI EX2100 Exciter Ground Detector Module
IS200EGDMH1AAB
IS200EGDMH1AAB
IS200EGDMH1AAB
IS200EGDMH1AAB
IS200EGDMH1AAB
IS200EGDMH1AAB

GE IS200EGDMH1AAB Mark VI EX2100 Exciter Ground Detector Module

  • Manufacturer: GE

  • Product No.: IS200EGDMH1AAB

  • Condition: En stock

  • Product Type: Ground Detector Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Product Overview

The IS200EGDMH1AAB functions as a critical Exciter Ground Detector Module (EGDM) within the GE Mark VI / EX2100 excitation system. This module identifies field ground leakage current across both AC and DC segments of the generator field circuit. It maintains high operational safety standards by detecting abnormal insulation resistance levels promptly. The unit utilizes a double-height (6U), double-slot form factor designed for seamless integration into the Exciter Power Backplane (EPBP).

Technical Specifications

  • Manufacturer: General Electric (GE)
  • Model Number: IS200EGDMH1AAB
  • Series Compatibility: Mark VI / EX2100 Excitation System
  • Dimensions: 15.9 cm x 10.2 cm
  • Operating Temperature: -30°C to +65°C
  • Measurement Range: Field leakage resistance monitoring
  • Technology: Surface-mount device (SMD) architecture
  • Resolution & Sensitivity: High-precision detection for early-stage fault identification
  • Environmental Tolerance: Conformal coating protects against industrial humidity and dust
  • Interference Resistance: Fiber-optic isolation minimizes electromagnetic interference (EMI)
  • Communication: Bidirectional optical transmission via HFBR2528/HFBR1528 connectors

Installation and Maintenance

  • Mount the module directly into the designated slot on the EPBP backplane.
  • Ensure the P1 and P2 backplane connectors are fully seated for reliable signal routing.
  • Connect fiber-optic cables carefully to U201 and U305 ports, ensuring clean optical faces.
  • Configuration of the IS200EGDMH1AAB for simplex or redundant systems is managed via P2 connector pins.
  • Monitor status using front-faceplate LEDs: Power, Master Selection, and 50V Signal status.
  • Periodic inspection of capacitors and resistors is recommended to ensure long-term reliability.

Compatibility and Applications

  • Designed specifically for the GE EX2100 excitation control environment.
  • Supports simplex (single module) and redundant (triple module <C>, <M1>, <M2>) architectures.
  • Integrates directly with EXAM (Excitation AMPlifier) modules for signal attenuation.
  • Ideal for power generation facilities and large-scale industrial excitation control cabinets.

Logistics and Warranty

  • Shipping Carriers: FedEx, UPS, and DHL for global delivery.
  • Processing Time: Expedited dispatch within 24-48 hours of order confirmation.
  • Warranty: Comprehensive 12-month quality assurance coverage.
  • Packaging: Secure industrial-grade static-shielded packaging.

Global PLC Spare HUB Insight

The IS200EGDMH1AAB represents a critical layer in the GE EX2100 protection strategy. Engineers favor this module for its robust optical isolation, which effectively decouples the sensitive control logic from high-voltage field circuits. By deploying redundant IS200EGDMH1AAB units, facility operators achieve high-availability fault detection that is vital for preventing unscheduled generator outages.

Frequently Asked Questions

Question: How do I identify if my IS200EGDMH1AAB is the master module?

Answer: The middle LED indicator on the front faceplate illuminates when the module is actively configured and selected as the master unit within the system hierarchy.

Question: Can I use this module in a non-redundant system?

Answer: Yes, a simplex system utilizes a single IS200EGDMH1AAB module to provide standard ground fault detection.

Question: What should I check if the power LED is not illuminated?

Answer: Verify the seating in the EPBP backplane and ensure that the P1/P2 power pins are receiving the required voltage from the power supply bus.

Selection Guide

  • Confirm your existing Mark VI system architecture before purchasing.
  • For critical applications, opt for the triple-module configuration to ensure redundant monitoring.
  • Verify the hardware revision number to ensure compatibility with your existing EX2100 boards.
  • Contact our technical team if your system requires custom integration support or specific documentation referencing GEH-6632.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.