EVS9328-ES Global Drive 9300 by Lenze Original Servo Drive
Manufacturer: Lenze
Product No.: EVS9328-ES
Condition: En stock
Product Type: Servo Drive
Product Origin: DE
Payment: T/T, Western Union
Weight: 12500g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Lenze EVS9328-ES Global Drive 9300 Servo Inverter
The Lenze EVS9328-ES is a 22 kW servo inverter from the Global Drive 9300 series. It is designed for controlled operation of three-phase asynchronous motors in industrial motion and automation systems.
This drive uses vector control and supports resolver, incremental TTL encoder, and SinCos encoder feedback through its dedicated interfaces. It integrates analog and digital I/O, CAN system bus communication, an AIF automation interface, and expansion options for additional fieldbus protocols.
The EVS9328-ES provides rated output current of 47.0 A at 8 kHz and 30.6 A at 16 kHz. Its maximum output current is 150% of rated current, subject to the specified operating conditions and switching frequency.
01 | Drive Identification & Performance Profile
| Identification Item | Technical Information |
|---|---|
| Manufacturer | Lenze |
| Model | EVS9328-ES |
| Product Series | Global Drive 9300 |
| Product Type | Servo Inverter |
| Rated Motor Power | 22.0 kW, 4-pole asynchronous motor, servo rating |
| Output Power | 32.6 kVA |
| Control Architecture | Vector control |
| Motor Voltage | Three-phase, 0 to Vmains |
| Weight | Approximately 12.5 kg |
Product identification: EVS9328-ES is the specified Lenze order code for the 22 kW power class. Confirm the complete nameplate code when replacing an existing drive.
02 | Output Ratings: Switching Frequency Matters
The available output current depends on the selected switching frequency. Engineers should use the corresponding current rating when sizing the motor and evaluating drive loading.
| Output Parameter | 8 kHz | 16 kHz |
|---|---|---|
| Rated Output Current | 47.0 A | 30.6 A |
| Maximum Output Current | 70.5 A | 45.9 A |
| Maximum Current Ratio | 150% × In | 150% × In |
Additional electrical ratings:
- Rated motor power: 22.0 kW.
- Output apparent power: 32.6 kVA.
- Mains current at 400 V: 44.0 A.
- Motor output voltage: 0 to Vmains, three-phase.
- Maximum output current: 150% of rated current.
The maximum output current figures are based on the published 150% × In ratings. An overload specification of 180% for 60 seconds is not adopted because it is not confirmed in the cited official product data.
03 | Supply Requirements and Power Loss
| Electrical Parameter | Specification |
|---|---|
| Supply Voltage | 320–528 V AC |
| Supply Frequency | 45–65 Hz |
| Mains Current at 400 V | 44.0 A |
| Power Loss at 400 V | 640 W |
| Power Derating Above 40°C | 2.5% per °C |
| Altitude Derating | 5% per 1,000 m from 1,000 to 4,000 m |
Panel design considerations:
- Size the upstream supply and protection devices according to the drive's electrical ratings and the applicable installation manual.
- Account for approximately 640 W of drive power loss when calculating cabinet heat dissipation.
- Provide sufficient ventilation and clearance around the inverter.
- Apply current derating when the ambient temperature exceeds 40°C.
- Include altitude-related derating for installations above 1,000 m.
04 | Motor Feedback and Control Interfaces
The 9300 servo platform supports several motor feedback technologies. The selected feedback device must match the motor, encoder interface, and configured control strategy.
| Interface | Function | Connection Details |
|---|---|---|
| X7 | Motor feedback | Resolver input and KTY motor temperature sensor |
| X8 | Encoder feedback | TTL incremental encoder or Stegmann SinCos encoder; KTY temperature sensor support |
| X1 | Automation interface | AIF interface |
| X3 | Analog input configuration | Jumper for analog input signal selection at X6/1 and X6/2 |
| X4 | System communication | CAN system bus |
| X5 | Digital I/O | Digital inputs and outputs |
| X6 | Analog I/O | Analog inputs and outputs |
| X9 | Frequency input | Digital frequency input |
| X10 | Frequency output | Digital frequency output |
| X11 | Safe standstill relay | K_SR relay output on V004/V104 variants only |
Specified analog interface signals:
- AIN1: X6.1 / X6.2.
- AOUT1: X6.62.
- AOUT2: X6.63.
The X11 K_SR relay output is variant-dependent. Do not assume this function is available on every EVS9328-ES hardware version. Verify the complete variant designation before using it in a safety-related design.
05 | Communication and Automation Integration
The Global Drive 9300 platform combines built-in communication interfaces with optional plug-in expansion modules.
| Communication Interface | Supported Function |
|---|---|
| RS232 / RS485 | Serial communication through Global Drive Control |
| CAN System Bus | Integrated system bus communication |
| AIF | Automation interface and expansion connection |
| INTERBUS-S | Fieldbus communication through a plug-in module |
| PROFIBUS | Fieldbus communication through a plug-in module |
| LECOM A/B | Serial communication using RS232/RS485 through the applicable interface configuration |
Communication capability depends on the installed expansion hardware and configuration. Confirm the required protocol module before integrating the drive into an existing PLC or DCS network.
06 | Braking System: External Hardware Required
The EVS9328-ES requires an external braking solution for applications that need controlled dissipation of regenerative energy. The published 9300 product information identifies the following brake components.
| Brake Component | Technical Specification | Application |
|---|---|---|
| 9351 Brake Module | Integrated 47 Ω brake resistor; maximum peak braking power 12 kW; 1% duty cycle per 4 seconds | External braking solution with integrated resistor |
| 9352 Brake Chopper | Minimum external braking resistance 18 Ω | External braking solution using a separately selected resistor |
Brake selection checks:
- Calculate the regenerative energy generated during deceleration.
- Check the required braking power and duty cycle.
- Verify the resistor value against the brake chopper requirements.
- Check thermal limits and resistor installation conditions.
- Follow the Lenze brake module and brake chopper installation instructions.
Do not treat the 9351 and 9352 as interchangeable resistor assemblies. Their braking hardware arrangements and external resistor requirements differ.
07 | Environmental Limits and Mechanical Installation
| Parameter | Specification |
|---|---|
| Operating Temperature | 0 to +50°C |
| Rated Output Above 40°C | Reduce output current by 2.5% per °C |
| Storage Temperature | -25 to +60°C |
| Relative Humidity | Average 85% RH, no condensation |
| Climatic Classification | 3K3 |
| Protection Rating | IP20 |
| Pollution Degree | 2 |
| Dimensions (H × W × D) | 350 × 250 × 250 mm |
| Weight | Approximately 12.5 kg |
Mechanical installation notes:
- The dimensions are family-aggregated values for the 9327, 9328, and 9329 models.
- The stated dimensions exclude additional depth from the terminal shield and front keypad attachment.
- IP20 protection requires installation inside a suitable electrical cabinet.
- Maintain adequate airflow and cabinet ventilation to manage drive heat losses.
- Prevent moisture condensation during operation and storage.
08 | Compliance and Electrical Safety
| Compliance Area | Reference |
|---|---|
| CE Conformity | Low-Voltage Directive 2006/95/EC |
| Electrical Safety | EN 61800-5-1 |
| EMC Category | C2 according to EN 61800-3, typical drive configuration |
| UL / UR | UL/UR safety and branch-circuit protection requirements documented in the applicable manual |
| Short-Circuit Rating | 5,000 / 50,000 A RMS symmetrical, 480 V maximum, depending on the specified fuse arrangement |
For UL/UR installations, use the specified J, T, or R class fuses and follow the applicable branch-circuit protection instructions. Confirm the required short-circuit current rating and protection arrangement for the actual installation.
09 | Commissioning and Drive Replacement Checklist
- Verify the drive rating: Match the EVS9328-ES power class and motor current requirements.
- Check the motor feedback: Identify whether the motor uses a resolver, TTL incremental encoder, or SinCos encoder.
- Review parameter compatibility: Back up existing drive parameters and record motor data before replacement.
- Confirm communication hardware: Check CAN, AIF, and any installed fieldbus expansion modules.
- Inspect braking equipment: Verify whether a 9351 brake module or 9352 brake chopper is required.
- Calculate cabinet cooling: Include the specified drive power loss and the actual operating environment.
- Check safety-related functions: Confirm the hardware variant and applicable safety documentation before using any safe standstill-related interface.
- Perform controlled startup: Verify rotation direction, feedback operation, acceleration, deceleration, and current loading.
Always isolate the power supply and follow the approved electrical safety procedure before installation or maintenance. Use the applicable Lenze manual for parameterization, wiring, and commissioning.
10 | Product Lifecycle and Replacement Planning
The Lenze Global Drive 9300 servo inverter belongs to a previous-generation product range. Lenze documents the i950 servo inverter as a migration path for 9300 applications.
The documented migration approach includes compatibility-related functions and engineering resources such as:
- i950 compatibility switch for supported 9300 behavior.
- Applicable i950 PROFIBUS communication module.
- L_ICIP library for supported migration and integration tasks.
A migration should not be treated as a direct hardware substitution. Engineers must review motor feedback, control behavior, fieldbus configuration, parameter mapping, safety functions, braking hardware, and cabinet wiring before selecting a replacement platform.
11 | Supply, Warranty and Shipping
| Commercial Information | Details |
|---|---|
| Manufacturer | Lenze |
| Model | EVS9328-ES |
| Product Series | Global Drive 9300 |
| Product Type | 22 kW Servo Inverter |
| Condition | New & Original in Factory Packing |
| Warranty | Factory Warranty: 12 Months |
| Shipping | FedEx, UPS, DHL |
Contact Global PLC Spare HUB for EVS9328-ES pricing, availability, and delivery information. For replacement projects, provide the motor nameplate, feedback type, communication requirements, and existing brake configuration to support a more accurate compatibility review.
12 | Engineering FAQs
Q1: Can I replace an EVS9328-ES with another 22 kW inverter based only on motor power?
No. Motor power alone is not sufficient for drive selection. Compare rated and peak output current, switching frequency, motor feedback, supply voltage, control mode, communication interfaces, and braking requirements. A replacement must also support the machine's acceleration, deceleration, and dynamic load profile.
Q2: Why does the available output current decrease when the switching frequency changes from 8 kHz to 16 kHz?
Higher switching frequency increases switching-related losses in the power stage. The drive therefore has a lower published continuous output current at 16 kHz. When configuring the application, use the current rating for the selected switching frequency rather than assuming the 8 kHz rating remains available.
Q3: What information should I collect before transferring parameters to a replacement drive?
Record the motor nameplate data, feedback device type, encoder resolution where applicable, control mode, speed and torque limits, acceleration and deceleration ramps, I/O assignments, and fieldbus settings. Also document brake control and machine interlocks. Parameter transfer should be followed by a controlled functional test.
Q4: How can I determine whether the existing braking hardware is suitable for a machine with frequent stopping cycles?
Estimate the regenerative energy per stop, stopping frequency, motor inertia, and required deceleration time. Compare the calculated braking duty with the 9351 module's specified peak power and duty cycle, or the 9352 chopper's resistor requirements. Frequent stopping may require a different braking design from an occasional emergency or normal deceleration cycle.
Q5: What should I investigate if a drive operates normally when cold but trips after the cabinet warms up?
Check cabinet temperature, ventilation, fan operation, surrounding heat sources, and actual motor current. Above 40°C, the specified output current must be derated by 2.5% per °C. Also inspect electrical connections and the drive's fault history. Do not increase current limits to compensate for inadequate cooling.
Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.