RGH22Y30D61A Renishaw Precision RGH22 Linear Encoder System
Manufacturer: Renishaw
Product No.: RGH22Y30D61A
Condition: متوفر بالمخزون
Product Type: Linear Encoder
Product Origin: UK
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
تقدير أوقات التسليم: 12-26 يومًا (دوليًا)، 3-6 أيام (الولايات المتحدة).
يجب الإرجاع خلال 30 يومًا من الشراء. الرسوم والضرائب غير قابلة للاسترداد.
دفع آمن ومضمون
Precision Position Feedback for Demanding Motion Systems
Renishaw RGH22Y30D61A is a non-contact optical encoder readhead from the RGH22 series. It provides reliable position feedback for precision linear motion applications. Its open optical architecture eliminates mechanical contact between the readhead and scale.
The readhead operates with the RGS20-S gold tape scale, which features a 20 μm incremental pitch. Integrated interpolation supports resolutions down to 50 nm, depending on the output configuration. Engineers can select compatible analogue or digital signal interfaces for their motion controllers.
Several practical features simplify machine integration. An integral setup LED assists optical alignment. Specialized filtering optics improve resistance to contamination. Integrated reference and limit sensors also reduce the need for separate sensing components.
01 | Product Identity & Configuration Breakdown
| Brand | Renishaw |
| Complete Model | RGH22Y30D61A |
| Product Family | RGH22 |
| Product Type | Non-contact Optical Encoder Readhead |
| Measurement Technology | Incremental Optical Position Feedback |
| Compatible Scale | RGS20-S Gold Tape Scale |
| Scale Pitch | 20 μm |
| Connector Configuration | D – 15-way D-sub connector |
| Readhead Mass | Approximately 45 g |
| Country of Manufacture | Not specified in the supplied documentation |
Model Configuration Reference
-
RGH22
- Identifies the RGH22 non-contact optical encoder readhead family.
- Supports incremental position measurement with integrated interpolation.
-
Y
- Identifies the specified RGH22 variant.
- Confirm the exact electrical output and resolution against the manufacturer's ordering documentation.
-
30
- Configuration code within the complete ordering reference.
- Its precise meaning requires the manufacturer's model-code definition.
-
D
- 15-way D-sub connector configuration.
-
61A
- Remaining ordering configuration suffix.
- Confirm its electrical and mechanical definitions before selecting a replacement.
Configuration Note: The suffix breakdown above distinguishes the supplied connector information from codes requiring further manufacturer documentation. It does not assume undocumented electrical characteristics.
02 | Optical Measurement & Signal Performance
| Measurement Method | Non-contact optical incremental encoding |
| Compatible Scale | RGS20-S gold tape scale |
| Scale Pitch | 20 μm |
| Interpolation | Integrated interpolation |
| Resolution Capability | 5 μm to 50 nm across the RGH22 range |
| Output Options | 1 Vpp analogue or RS422 digital, depending on configuration |
| Reference Sensor | Integrated |
| Limit Sensors | Integrated |
| Setup Assistance | Integral LED indicator |
| Optical Protection | Specialized filtering optics |
Engineering Interpretation: The 50 nm figure represents the finest resolution capability stated for the RGH22 family. It should not be interpreted as absolute measurement accuracy or guaranteed system repeatability. Actual performance depends on the readhead variant, scale installation, controller interface, and mechanical system.
03 | Electrical Interface & Power Requirements
| Supply Voltage | 5 V DC ±5% |
| Typical Current Consumption | 200 mA for RGH22Y |
| Power Supply Standard | SELV requirements, IEC BS EN 60950-1 |
| Maximum Supply Ripple | 200 mVpp at frequencies up to 500 kHz |
| Digital Output Options | RS422 differential signals |
| Analogue Output Options | 1 Vpp signals |
| Digital Termination Current | Additional 25 mA per terminated channel pair at 120 Ω |
| Analogue Termination Current | Additional 20 mA with 120 Ω termination |
| Connector | 15-way D-sub |
Power Design Consideration: Current consumption figures refer to unterminated readheads. Digital and analogue termination conditions introduce additional current requirements. Size the 5 V supply according to the actual interface configuration.
04 | Cable Construction & Mechanical Durability
- Conductors: 12-core cable.
- Shielding: Double-shielded construction.
- Maximum Cable Diameter: 4.7 mm.
- Flex Life: More than 20 × 10⁶ cycles.
- Test Bend Radius: 50 mm.
- Readhead Mass: 45 g.
- Cable Mass: 38 g/m.
The flexible cable supports repeated movement in dynamic machine installations. Double shielding helps reduce susceptibility to electrical interference. Maintain the specified bend radius during cable routing to protect conductor integrity.
05 | Environmental & Operating Limits
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -20°C to +70°C |
| Relative Humidity | Up to 95%, non-condensing |
| Humidity Standard | EN 60068-2-78 |
| Ingress Protection | IP50 |
| Operating Acceleration | 500 m/s², 3 axes |
| Operating Vibration | 100 m/s² maximum, 55 Hz to 2000 Hz, 3 axes |
| Non-operating Shock | 1000 m/s², 6 ms, half-sine, 3 axes |
Installation Environment: IP50 protection does not provide protection against water ingress. Avoid condensation, liquid exposure, and heavy airborne contamination. Use suitable machine guarding when the installation environment requires additional protection.
06 | Installation & Optical Alignment
Step 1 – Scale Preparation
Clean the mounting substrate before applying the RGS20-S scale. Check the mounting surface for flatness and contamination. Select a substrate compatible with the scale installation method.
Step 2 – Scale Mounting
The RGS20-S uses a specially formulated pre-applied adhesive. Epoxy-fastened end clamps secure the scale. This mounting arrangement minimizes differential movement between the scale and substrate during temperature changes.
Step 3 – Readhead Positioning
Position the RGH22 readhead according to the manufacturer's optical and mechanical alignment specifications. Maintain the required readhead-to-scale relationship. Avoid mechanical contact with the scale during axis movement.
Step 4 – LED Setup Verification
Use the integral setup LED during alignment. Check the indicator according to the manufacturer's installation procedure. Correct optical positioning before finalizing the mounting arrangement.
Step 5 – Electrical Connection
Connect the 15-way D-sub interface to the compatible controller or signal-processing equipment. Verify the 5 V supply polarity and voltage. Check output-interface compatibility before applying power.
Step 6 – Motion Validation
Move the axis slowly through its operating range. Confirm incremental signal stability and reference sensor operation. Check limit sensor responses where the machine configuration uses them.
07 | Engineering Applications & Integration Advantages
- Metrology Equipment: Provides incremental position feedback for precision measuring systems.
- Semiconductor Manufacturing: Supports controlled positioning in precision motion assemblies.
- Flat Panel Display Production: Provides position feedback for automated linear stages.
- Electronics Manufacturing: Supports repeatable motion control in automated production equipment.
- Linear Motion Systems: Integrates optical feedback into compatible machine axes.
The open optical architecture avoids mechanical contact between the readhead and scale. Filtering optics improve tolerance to dirt contamination. Integrated interpolation reduces the need for separate external interpolation hardware.
08 | Compatibility & Purchasing Considerations
Before selecting RGH22Y30D61A, engineers should verify the following integration details:
- Confirm compatibility with the RGS20-S 20 μm gold tape scale.
- Match the output type to the motion controller input.
- Verify the 15-way D-sub connector arrangement.
- Check the 5 V DC power supply capacity.
- Confirm the required interpolation resolution.
- Check reference and limit sensor requirements.
- Verify cable routing and minimum bend radius.
- Confirm mounting geometry and environmental limits.
Replacement Recommendation: When replacing an existing Renishaw encoder, compare the complete part number rather than relying on the RGH22 series designation alone. Output format, connector arrangement, resolution, and scale compatibility determine successful integration.
09 | Quality Assurance & Warranty
- Warranty: 12 months.
- Model Verification: Part number and configuration checks before order confirmation.
- Application Support: Assistance with encoder selection and compatibility verification.
- Shipping Options: FedEx, UPS, and DHL.
- Application Areas: Precision motion control, metrology, semiconductor, and electronics manufacturing.
Contact our team to confirm product availability, configuration details, and purchasing requirements.
10 | Frequently Asked Questions
Q1: Why does an optical encoder require a reference position during machine startup?
An incremental encoder measures relative movement rather than automatically identifying an absolute machine coordinate. The controller typically performs a reference operation to establish the machine origin. The integrated reference sensor supports this process.
Q2: How does scale mounting affect positioning accuracy over long travel distances?
Scale mounting stability directly influences the relationship between measured position and actual axis movement. Thermal expansion differences can introduce measurement errors. The RGS20-S adhesive and end-clamp arrangement helps minimize differential movement relative to the substrate.
Q3: What maintenance action is most useful when optical signal quality deteriorates?
Inspect the scale surface and readhead alignment before replacing electronic components. Check for oil films, dust accumulation, mechanical movement, and damaged cable shielding. Use the setup LED to assist alignment checks.
Q4: Should engineers select 50 nm resolution for every precision motion application?
No. Higher resolution does not automatically improve overall positioning accuracy. Evaluate machine stiffness, guideway performance, controller interpolation, scale installation, and feedback bandwidth. Select resolution according to the complete motion-control system.
Q5: What information should buyers provide when sourcing an RGH22 replacement?
Provide the complete readhead model, existing scale reference, output interface, connector type, and required resolution. Include the controller model when possible. These details help verify electrical and mechanical compatibility before procurement.
Tags
س: هل هذه الأجزاء أصلية وجديدة 100%؟
ج: نعم. نضمن أن كل مكون هو أصلي 100%، وجديد تمامًا، ومغلف من المصنع. كما نقدم ضمانًا شاملاً لمدة 12 شهرًا لراحتك.
س: ما مدى سرعة الشحن إلى بلدي؟
ج: بالنسبة للعناصر المتوفرة في المخزون، نقدم إرسالاً في نفس اليوم. وعادةً ما يتم التسليم عبر الشحن السريع الدولي (DHL/FedEx/UPS) في غضون 3-5 أيام عمل في جميع أنحاء العالم.
س: هل يمكنني الحصول على عرض أسعار رسمي يشمل تكاليف الشحن؟
ج: بالتأكيد. فريق المبيعات لدينا مستعد لتقديم فاتورة مبدئية (PI) مفصلة تتضمن أسعار الشحن الأكثر تنافسية لموقعك.
س: هل تقدمون خصومات للطلبات الكبيرة؟
ج: نقدم أسعارًا تعتمد على الحجم للمشاريع الكبيرة أو طلبات العناصر المتعددة. يرجى الاتصال بنا للحصول على ضمان أفضل الأسعار لدينا.
ضمان شامل لمدة 12 شهرًا
كل جزء توفره Global PLC Spare Hub مشمول بـ ضمان لمدة 12 شهرًا من تاريخ الفاتورة.
- التغطية: عيوب وظيفية وأعطال في الأجهزة في ظل ظروف التشغيل العادية.
- التزامنا: نقدم إصلاحًا فوريًا أو استبدالًا أو استردادًا كاملاً لأي مكونات معيبة تم التحقق منها لتقليل وقت التوقف التشغيلي لديك.
سياسة الإرجاع والاستبدال
نقدم سياسة إرجاع لمدة 30 يومًا لضمان حصولك على الجزء الدقيق الذي يتطلبه نظامك.
- الأهلية: تُقبل المرتجعات للعناصر غير المركبة في تغليفها الأصلي والمحكم الإغلاق من المصنع.
- عملية RMA: يرجى الاتصال بفريق الدعم لدينا للحصول على رقم ترخيص إرجاع البضائع (RMA) قبل الشحن.
- معالجة سريعة: تتم معالجة المبالغ المستردة أو الاستبدالات في غضون 3-5 أيام عمل بعد أن يجتاز العنصر المرتجع فحصنا الفني.
هل تحتاج إلى مساعدة فنية؟لست متأكدًا مما إذا كان هذا الجزء متوافقًا مع نظامك؟ [استشر مهندسينا] قبل الشراء لضمان التوافق بنسبة 100%.