Renishaw RGH22B50L00A Linear Optical Encoder Readhead
Manufacturer: Renishaw
Product No.: RGH22B50L00A
Condition: متوفر بالمخزون
Product Type: Encoder Readhead
Product Origin: UK
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
تقدير أوقات التسليم: 12-26 يومًا (دوليًا)، 3-6 أيام (الولايات المتحدة).
يجب الإرجاع خلال 30 يومًا من الشراء. الرسوم والضرائب غير قابلة للاسترداد.
دفع آمن ومضمون
Product Overview
The Renishaw RGH22B50L00A is a non-contact optical linear encoder readhead. It belongs to the RGH22 series within the RG2 incremental encoder system.
This readhead provides 1 Vpp differential analogue output for precision linear position feedback. It operates with the 20 µm pitch RGS20-S reflective steel scale.
The RGH22B configuration includes a single limit sensor and an integrated reference mark sensor. Its open optical design supports non-contact position measurement without mechanical contact with the scale.
The integrated set-up LED helps engineers check installation alignment. Internal signal interpolation supports stable position feedback in motion control applications.
The 5 m cable and 15-way D-type connector simplify integration with compatible controller interfaces. The standard 00A configuration provides the specified factory connection arrangement.
Key Features
- Optical measurement: Non-contact incremental linear position detection.
- Signal output: 1 Vpp differential analogue signals.
- Scale compatibility: 20 µm pitch RGS20-S reflective steel scale.
- Limit detection: Integrated single limit sensor.
- Reference positioning: Integrated reference mark detection.
- Installation support: Built-in multicolour set-up LED.
- Cable assembly: 5 m, 12-core, double-shielded cable.
- Connector: 15-way D-type plug.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Renishaw |
| Model | RGH22B50L00A |
| Product Series | RGH22 / RG2 |
| Product Type | Open Optical Linear Encoder Readhead |
| Measurement Principle | Non-contact optical incremental measurement |
| Output Type | 1 Vpp differential analogue |
| Scale Compatibility | RGS20-S reflective steel tape scale |
| Scale Pitch | 20 µm |
| Limit Configuration | Single limit sensor |
| Reference Mark | Integrated reference mark sensor |
| Cable Length | 5 m |
| Cable Construction | 12-core, double-shielded, high-flexibility cable |
| Maximum Cable Diameter | 4.7 mm |
| Connector Type | 15-way D-type plug |
| Configuration | 00A Standard |
| Supply Voltage | 5 V DC ±5% |
| Typical Current Consumption | 120 mA, unterminated readhead |
| Additional Termination Current | Approximately 20 mA with 120 Ω analogue termination |
| Maximum Analogue Readhead Speed | 4 m/s at −3 dB |
| Ride Height | 0.8 ±0.1 mm |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | −20 °C to +70 °C |
| Protection Rating | IP50 |
| Operating Humidity | 95% RH, non-condensing |
| Operating Acceleration | 500 m/s², three axes |
| Operating Vibration | 100 m/s² maximum, 55 Hz to 2000 Hz, three axes |
| Non-operating Shock | 1000 m/s², 6 ms, half-sine, three axes |
| Readhead Weight | 45 g, excluding cable |
Measurement Performance
- Measuring range: The scale determines the available measuring length. RGS20-S supports lengths up to 50 m.
- Signal period: The analogue signal corresponds to the 20 µm scale pitch.
- Maximum speed: The RGH22A/B analogue range supports up to 4 m/s at −3 dB.
- Scale linearity: RGS20-S provides ±3 µm/m scale linearity.
- Resolution: The analogue output does not specify one fixed digital resolution. The receiving controller determines interpolation resolution.
- Sensitivity: The manufacturer specifies 1 Vpp differential output rather than a separate sensitivity value.
- Frequency response: The manufacturer specifies maximum analogue speed at −3 dB. Confirm controller bandwidth before system design.
Installation Guide
Correct mechanical alignment directly affects signal quality and measurement stability.
- Confirm the machine uses the compatible RGS20-S 20 µm scale.
- Clean the mounting surface before installing the scale.
- Maintain the specified scale alignment with the machine travel axis.
- Mount the readhead using the designated fixing holes.
- Set the readhead ride height to 0.8 ±0.1 mm.
- Check the pitch and roll alignment against the installation drawing.
- Position the reference mark actuator correctly along the measuring axis.
- Position the single limit actuator within its specified sensing area.
- Use the integrated set-up LED to check optical alignment.
- Connect the 15-way D-type plug to the compatible receiving interface.
- Verify the 5 V DC supply before enabling machine movement.
Maintain the cable bend radius during installation. Follow the manufacturer's dynamic and static bend requirements.
Commissioning and Maintenance
- Power verification: Check the 5 V DC supply and voltage stability.
- Signal verification: Measure both differential analogue signal pairs.
- Signal balance: Check signal amplitude and waveform quality during axis movement.
- Reference testing: Confirm repeatable reference mark detection in the intended travel direction.
- Limit testing: Verify the single limit output with its actuator.
- Alignment inspection: Check the set-up LED and specified ride height.
- Shielding inspection: Verify the inner and outer shield connections.
- Mechanical inspection: Check scale adhesion, contamination and cable condition.
For electrical noise control, follow Renishaw's grounding arrangement. Connect the outer shield to machine earth. Connect the inner shield to 0 V. Keep both shields electrically isolated.
Compatibility and Application
The RGH22B50L00A requires a compatible RGS20-S optical scale. The receiving controller must support 1 Vpp differential analogue inputs.
Engineers should verify the connector pinout, supply voltage and signal termination before installation.
Typical application areas include:
- Coordinate measuring and dimensional inspection machines.
- Precision linear positioning systems.
- Semiconductor and electronics manufacturing equipment.
- Flat panel display production equipment.
- Automated inspection and measurement systems.
- Linear motor positioning platforms.
- Electronics assembly and testing equipment.
Compatibility note: Do not treat digital RS422 RGH22 variants as direct electrical replacements. Their output interfaces differ from the RGH22B analogue configuration.
Environmental Resistance and Signal Integrity
The RGH22 readhead uses a double-shielded cable to support signal integrity. Its open optical design requires suitable protection from external contamination.
- Ingress protection: IP50 protects against dust ingress at the specified test level. It does not provide water protection.
- Electrical noise: Correct grounding and shield separation help reduce interference.
- Vibration: The readhead supports the specified operating vibration conditions.
- Mechanical shock: The datasheet specifies a non-operating shock limit.
- Temperature: Maintain the readhead within its rated operating range.
Certification and Compliance
The RGH22 technical datasheet specifies electrical, environmental and mechanical operating limits.
It also references a 5 V DC supply compliant with SELV requirements under IEC BS EN 60950-1.
Specific product certification documents are not confirmed by the available model information. Please request applicable declarations and certificates when required.
Package Contents
- 1 × Renishaw RGH22B50L00A optical encoder readhead.
- 1 × Integrated 5 m double-shielded cable.
- 1 × 15-way D-type connector.
- Product identification and applicable documentation, subject to supply scope.
Note: The RGS20-S scale and mounting accessories are separate items unless the quotation explicitly includes them. Confirm the delivery scope before ordering.
Frequently Asked Questions
Q1: Which scale works with the RGH22B50L00A?
The compatible scale is the Renishaw RGS20-S reflective steel tape scale. It uses a 20 µm pitch.
Q2: Does the RGH22B50L00A provide digital RS422 output?
No. This model provides 1 Vpp differential analogue output. Select a digital RGH22 variant for RS422 signals.
Q3: Can the readhead operate without an RGS20-S scale?
No. The optical readhead requires a compatible scale for incremental position measurement.
Q4: Why does the analogue signal become unstable after installation?
First inspect ride height, optical alignment and scale cleanliness. Then check the 5 V supply, grounding and cable shielding. Incorrect termination can also affect waveform quality.
Q5: What should engineers check when replacing an existing RGH22 readhead?
Compare the complete part number, output type, cable length and connector. Also verify the limit configuration and reference mark operation.
Q6: Can a controller accept the RGH22B output directly?
Only if its input supports compatible 1 Vpp differential analogue signals. Check input impedance, bandwidth and signal conditioning requirements.
Q7: Does the 20 µm scale pitch represent the final positioning resolution?
No. The controller determines the final interpolated resolution. Check its interpolation capability and input specifications.
Q8: Does the 5 m cable support long-distance signal transmission?
The integrated cable measures 5 m. The manufacturer permits longer extension arrangements under specified shielding and wiring conditions. Consult the RGH22 installation documentation before extending the cable.
Q9: What information should buyers confirm before ordering?
Confirm the complete model number, connector, cable length and scale compatibility. Also check the controller input type and required mounting accessories.
Q10: Is the RGS20-S scale included with this readhead?
Not automatically. The readhead and scale form separate system components. Confirm the quotation and packing list before purchase.
Tags
س: هل هذه الأجزاء أصلية وجديدة 100%؟
ج: نعم. نضمن أن كل مكون هو أصلي 100%، وجديد تمامًا، ومغلف من المصنع. كما نقدم ضمانًا شاملاً لمدة 12 شهرًا لراحتك.
س: ما مدى سرعة الشحن إلى بلدي؟
ج: بالنسبة للعناصر المتوفرة في المخزون، نقدم إرسالاً في نفس اليوم. وعادةً ما يتم التسليم عبر الشحن السريع الدولي (DHL/FedEx/UPS) في غضون 3-5 أيام عمل في جميع أنحاء العالم.
س: هل يمكنني الحصول على عرض أسعار رسمي يشمل تكاليف الشحن؟
ج: بالتأكيد. فريق المبيعات لدينا مستعد لتقديم فاتورة مبدئية (PI) مفصلة تتضمن أسعار الشحن الأكثر تنافسية لموقعك.
س: هل تقدمون خصومات للطلبات الكبيرة؟
ج: نقدم أسعارًا تعتمد على الحجم للمشاريع الكبيرة أو طلبات العناصر المتعددة. يرجى الاتصال بنا للحصول على ضمان أفضل الأسعار لدينا.
ضمان شامل لمدة 12 شهرًا
كل جزء توفره Global PLC Spare Hub مشمول بـ ضمان لمدة 12 شهرًا من تاريخ الفاتورة.
- التغطية: عيوب وظيفية وأعطال في الأجهزة في ظل ظروف التشغيل العادية.
- التزامنا: نقدم إصلاحًا فوريًا أو استبدالًا أو استردادًا كاملاً لأي مكونات معيبة تم التحقق منها لتقليل وقت التوقف التشغيلي لديك.
سياسة الإرجاع والاستبدال
نقدم سياسة إرجاع لمدة 30 يومًا لضمان حصولك على الجزء الدقيق الذي يتطلبه نظامك.
- الأهلية: تُقبل المرتجعات للعناصر غير المركبة في تغليفها الأصلي والمحكم الإغلاق من المصنع.
- عملية RMA: يرجى الاتصال بفريق الدعم لدينا للحصول على رقم ترخيص إرجاع البضائع (RMA) قبل الشحن.
- معالجة سريعة: تتم معالجة المبالغ المستردة أو الاستبدالات في غضون 3-5 أيام عمل بعد أن يجتاز العنصر المرتجع فحصنا الفني.
هل تحتاج إلى مساعدة فنية؟لست متأكدًا مما إذا كان هذا الجزء متوافقًا مع نظامك؟ [استشر مهندسينا] قبل الشراء لضمان التوافق بنسبة 100%.