Home SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter
SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter

SPXCDULNRFD Honeywell Sensepoint XCD Fixed Gas Detector Transmitter

  • Manufacturer: Honeywell

  • Product No.: SPXCDULNRFD

  • Condition: In stock

  • Product Type: Gas Detector Transmitter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Overview

Engineered for hazardous industrial environments, the SPXCDULNRFD transmitter represents a core variant of the Sensepoint XCD series by Honeywell. Designed for remote flammable gas detection, this SPXCDULNRFD unit operates reliably under extreme conditions ranging from -40 °C to +65 °C. Built within a rugged epoxy-painted LM25 aluminum alloy housing rated at IP66, it delivers precise 4-20 mA current outputs and robust relay integration to protect critical facility infrastructure.

Technical Specification Matrix

Engineering Parameter Operational Specification
Brand / Manufacturer Honeywell
Model Number SPXCDULNRFD
Product Series Sensepoint XCD Gas Detection Series
Device Classification Fixed Gas Detector Transmitter (Remote Flammable Detector)
Operating Voltage Range 16 to 32 VDC (24 VDC nominal)
Maximum Power Consumption 5 W (Max over range current up to 22.0 mA)
Current Output Options Sink or source, 4-20 mA (0-22 mA extended range)
Relay Configurations 3 x Form C relays (5 A at 250 VAC), programmable NO/NC
Enclosure & IP Rating Epoxy painted blue LM25 aluminum alloy, IP66 rating
Operating Temperature -40 °C to +65 °C
Humidity Tolerance Continuous 20-90% RH; Intermittent 0-99% RH (Non-Condensing)
Terminal & Conduit Details 18 x screw terminals (20AWG to 14AWG), 3 x 3/4" NPT entries
Operating Pressure Range 90 to 110 kPa
Physical Weight 4.4 lbs

Mechanical Installation Protocol

  • Mount the SPXCDULNRFD transmitter securely onto vertical structural supports or walls using robust brackets within classified hazardous zones.
  • Route field wiring through the three 3/4" NPT conduit entries, terminating individual conductors into the 18 screw terminals supporting 20AWG to 14AWG wire sizes.
  • Verify that the DC power supply maintains a steady voltage between 16 to 32 VDC prior to energizing the unit.
  • Ensure enclosure sealing gaskets remain undamaged to preserve the IP66 environmental protection rating against moisture and dust ingress.

Commissioning and Operational Maintenance

  • Configure the onboard programmable relays for normally open (NO) or normally closed (NC) operational logic depending on your emergency shutdown scheme.
  • Monitor 4-20 mA loop feedback signals to verify that calibration gas responses align correctly with expected sensor output scaling.
  • Inspect terminal blocks and conduit seals periodically during routine plant turnarounds to prevent environmental corrosion.
  • Store spare units within the safe temperature bracket of -25 °C to +65 °C when not deployed in active service loops.

System Compatibility and Integration

  • Fully compatible with standard industrial control systems and safety PLCs accepting 4-20 mA analog current loops.
  • Interfaces seamlessly with remote alarm panels and emergency ventilation systems via its three high-capacity 5 A relays.
  • Designed for direct integration into existing brownfield or greenfield gas monitoring safety architectures.

Fulfillment, Warranty, and Logistics

  • Package Contents: One SPXCDULNRFD gas detector transmitter unit and installation manual.
  • Warranty Coverage: Backed by an exhaustive 12-month replacement and repair warranty covering manufacturing flaws.
  • Shipping Services: Rapid worldwide fulfillment within 24-48 hours via FedEx, UPS, and DHL.

Target Industrial Applications

  • Upstream oil and gas extraction platforms and downstream refining complexes.
  • Chemical processing plants handling combustible solvent vapors.
  • Wastewater treatment biogas generation and distribution facilities.
  • Heavy manufacturing plants utilizing flammable industrial gases.

Advanced Diagnostic Architecture

  • Continuous internal health monitoring tracks loop integrity and flags abnormal power consumption anomalies.
  • Over-range current capability up to 22.0 mA provides distinct diagnostic status differentiation from standard operational gas readings.
  • Solid-state protection features safeguard against electrical surges and transient voltage spikes.

Frequently Asked Questions (FAQ)

What is the primary function of the SPXCDULNRFD transmitter?

The SPXCDULNRFD serves as a fixed gas detector transmitter designed for remote monitoring of combustible and flammable gases in harsh industrial environments.

How are external alarm devices connected to this transmitter?

The unit features three programmable onboard relays rated at 5 A and 250 VAC, which can be wired as normally open (NO) or normally closed (NC) to trigger external horns or strobes.

Can this transmitter operate in sub-zero outdoor conditions?

Yes, it features an operating temperature range extending from -40 °C to +65 °C, making it fully suitable for cold outdoor industrial climates.

What wire gauges are compatible with the terminal blocks?

The internal terminal strip includes 18 screw terminals engineered to accept wire sizes ranging from 20AWG to 14AWG.

What should I consider when selecting a gas transmitter for explosive atmospheres?

When purchasing safety instrumentation, always verify that the housing material (such as epoxy-painted LM25 aluminum), IP rating (IP66), and power supply tolerances (16 to 32 VDC) match the exact hazardous area classification of your plant site.

Global PLC Spare HUB's Insight & Field Experience

Deploying fixed gas detectors like the SPXCDULNRFD in offshore oil and gas facilities often presents severe challenges regarding salt-spray corrosion and electrical interference. During a recent compressor station safety upgrade, our engineering team encountered erratic signal fluctuations on a long analog cable run. Investigation revealed that ungrounded conduit shields were picking up high-frequency electromagnetic noise from nearby variable frequency drives. By isolating the shield properly at the controller end and ensuring the transmitter housing maintained a solid earth ground through its mounting bolts, we eliminated loop noise and stabilized the 4-20 mA output, securing continuous compliance for the plant's SIL safety loop.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.