ALR111-S01 Yokogawa ALR111 RS-232C Communication Module
Manufacturer: Yokogawa
Product No.: ALR111-S01
Condition: In stock
Product Type: Communication Module
Product Origin: JP
Payment: T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Industrial Communication Solution Overview
ALR111-S01 is a high-reliability serial communication module developed by Yokogawa.
The module supports stable RS-232C communication in industrial control systems.
ALR111-S01 integrates seamlessly with Yokogawa SCS architectures.
The design focuses on communication stability, subsystem integration, and Modbus slave connectivity.
Engineers commonly deploy this module in distributed control and process automation environments.
The ISA Standard G3 coating improves durability in corrosive industrial atmospheres.
This module supports point-to-point half-duplex communication with binary transmission coding.
The dual-port structure simplifies subsystem communication deployment.
Global PLC Spare HUB's Insight
Yokogawa ALR111 Series modules are widely used in process-critical automation systems.
The module performs reliably in high-noise industrial environments.
Its Modbus communication capability supports stable third-party device integration.
Many engineers choose this model for long-term communication stability and maintenance convenience.
The ISA G3 specification improves operational reliability in chemical and offshore environments.
This module is suitable for:
- Distributed Control Systems (DCS)
- Process automation systems
- Industrial communication gateways
- Energy management systems
- SCADA integration architectures
- Factory communication networks
Recommended application industries include:
- Oil and gas
- Petrochemical plants
- Power generation
- Water treatment
- Pharmaceutical manufacturing
- Heavy industrial automation
Diagnostic capabilities include:
- Communication fault monitoring
- Serial transmission verification
- Subsystem connection diagnostics
- Modbus communication status analysis
- Industrial network troubleshooting support
Module Architecture
| Brand | Yokogawa |
| Model | ALR111-S01 |
| Series | ALR111 Serial Communication Module |
| Communication Interface | RS-232C |
| Communication Method | Point-to-point |
| Transmission Mode | Half-duplex |
| Synchronization Method | Start-stop synchronization |
| Transmission Code | Binary |
| Character Length | 8 bits |
| Stop Bit Length | 1 / 2 bits |
| Parity Check | None / Even / Odd |
| Transmission Distance | Maximum 15 m |
| Transmission Delay | 1 ms after data transmission |
| Communication Speeds | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps |
| Connection Ports | D-sub 9-pin female × 2 |
| Communication Functions | Modbus slave and subsystem communication |
| Current Consumption | 0.5 A |
| Weight | Approx. 0.3 kg |
| Environmental Protection | ISA Standard G3 |
| Installation Platforms | SSC60 / SSC50 / SSC57 / SSC10 / SNB10D |
| Supported Wiring | AKB131 / AKB132 / AKB135 / AKB136 cables |
Configuration Breakdown
-
ALR111-S01
-
Base Model
- ALR111 = Serial Communication Module
-
Suffix Code Structure
- S = Standard type
- 0 = Without explosion protection
- 1 = ISA Standard G3 protection
-
Base Model
Engineering Design Features
- Dual-port communication architecture improves subsystem flexibility
- Supports industrial Modbus slave communication environments
- Maintains stable binary data transmission performance
- Supports configurable parity and stop-bit settings
- Designed for Yokogawa SCS communication integration
- ISA G3 coating improves resistance to corrosive atmospheres
- Compact hardware structure simplifies cabinet installation
Installation and System Integration
- Mount directly onto SSC60, SSC50, SSC57, SSC10, or SNB10D units
- SNB10D communicates through the ESB bus structure
- Use compatible Yokogawa communication cables for stable transmission
- Both communication ports must use identical communication functions
- Verify communication speed consistency before commissioning
- Ensure proper RS-232C grounding practices during installation
Communication Engineering Notes
- Mixed communication types cannot operate simultaneously on one module
- Subsystem communication fixes the character length to 8 bits
- Subsystem communication fixes the stop bit length to 1 bit
- Communication performance depends on wiring quality and grounding conditions
- Transmission distance should remain within 15 meters
Packaging Information
- 1 × ALR111-S01 communication module
- Protective industrial packaging
- Product identification labeling
- Inspection and handling protection materials
Shipping and Warranty Terms
- Warranty Period: 12 months
- Shipping Methods: FedEx, UPS, DHL
- Dispatch Lead Time: Fast international processing available
- Packaging Method: Industrial-grade anti-static protection
Professional FAQ
-
Why do both communication ports require identical communication functions?
The hardware architecture processes one communication protocol type per module.
-
What installation issue commonly affects RS-232C stability?
Poor grounding often introduces communication noise and intermittent faults.
-
How should engineers select the correct communication speed?
Match the baud rate with the connected subsystem specifications.
-
What advantage does ISA Standard G3 provide?
It improves reliability in corrosive industrial environments.
-
Which application environments benefit most from this module?
Process automation systems requiring stable serial communication integration.
-
What practical issue appears during long-term subsystem operation?
Improper cable shielding may increase communication retries and signal instability.
-
How can users reduce communication interruptions?
Use high-quality shielded cables and stable grounding practices.
-
What should buyers confirm before ordering?
Verify compatibility with the installed Yokogawa SSC platform.
-
Why is half-duplex communication useful in industrial systems?
It reduces wiring complexity and supports reliable serial data exchange.
-
What maintenance practice improves communication reliability?
Regularly inspect D-sub connectors for oxidation and loose connections.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



