628H13TDE1B MKS Instruments 600 Series Precision Absolute Transducer

  • Manufacturer: MKS Instruments

  • Product No.: 628H13TDE1B

  • Condition: In stock

  • Product Type: Absolute Pressure Transducer

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

MKS Instruments 628H13TDE1B | 100°C Heated Baratron Absolute Pressure Transducer

The MKS Instruments 628H13TDE1B is a heated capacitance manometer from the 628H Series within the MKS 600 Series.

This model measures absolute pressure across a 1000 Torr full-scale range. Its internal sensor maintains a controlled temperature of 100°C. The heated architecture supports demanding semiconductor and vacuum process environments.

The instrument combines a 0.25% reading accuracy specification with 0.001% full-scale resolution. Its analog output provides a 0 to +10 VDC pressure signal. A 15-pin D-sub connector supports electrical integration with compatible monitoring equipment.

The 628H13TDE1B also features vertical calibration and Inconel wetted construction. Its compact housing supports integration into semiconductor process equipment and vacuum measurement assemblies.

01 | Instrument Specification at a Glance

Manufacturer MKS Instruments
Model Number 628H13TDE1B
Product Series 628H Series
Product Family 600 Series
Product Type Heated Baratron Absolute Pressure Transducer
Measurement Principle Capacitance Manometer
Measurement Mode Absolute Pressure
Full-Scale Range 1000 Torr
Sensor Temperature 100°C
Calibration Orientation Vertical
Pressure Output 0 to +10 VDC
Process Connection NW16 ISO-KF, subject to model-code verification
Wetted Material Inconel
Compliance CE

02 | Measurement Performance & Resolution

The 628H series supports multiple pressure ranges and measurement configurations. The specified 1000 Torr version provides the following performance characteristics.

Parameter Specification
Full-Scale Range 1000 Torr
Measurement Accuracy ±0.25% of Reading
Accuracy Components Non-linearity, hysteresis, and non-repeatability included
Resolution 0.001% FS
Equivalent Resolution 0.01 Torr at 1000 Torr FS
Warm-Up Time 2 hours
Calibration Position Vertical

Measurement Accuracy: The ±0.25% reading specification includes non-linearity, hysteresis, and non-repeatability. It applies to the 1–25,000 Torr range configurations.

At a 1000 Torr full-scale range, 0.001% FS resolution corresponds to 0.01 Torr. Resolution and accuracy represent different measurement characteristics.

03 | 628H Series: Available Pressure Range Architecture

The 628H family covers a broad pressure range for different vacuum and process measurement requirements.

Range Group Available Full-Scale Ranges
Ultra-Low Pressure 0.05, 0.1, 0.25 Torr
Low Pressure 1, 2, 10, 20 Torr
Medium Pressure 100, 1000 Torr
High Pressure 2000, 5000, 10000 Torr
Extended Pressure 15000, 20000, 25000 Torr

Range-Dependent Performance:

  • 1–25,000 Torr: Accuracy is 0.25% of reading.
  • 0.25, 0.1, and 0.05 Torr: Accuracy is 0.50% of reading.
  • 0.05 Torr Range: Resolution is 0.002% FS.
  • Other Listed Ranges: Resolution is 0.001% FS.

The 628H13TDE1B specifically uses the 1000 Torr configuration. Do not apply the lowest-range specifications to this model.

04 | Model Suffix & Configuration Breakdown

The complete model number identifies the instrument family, pressure range, connection, accuracy class, calibration configuration, and electrical connector.

Code Segment Configuration Engineering Description
628H Product Series 100°C heated absolute Baratron pressure transducer
13T Pressure Range 1000 Torr full scale
D Fitting Code Supplied code description indicates 8 VCR female
E Accuracy Class ±0.25% of reading
1 Configuration Standard configuration with vertical calibration
B Electrical Connector 15-pin D-sub with thread locks

Complete Model: 628H13TDE1B

Configuration Verification: The supplied model description contains a fitting discrepancy. The product specification lists NW16 ISO-KF, while the supplied suffix explanation assigns code D to 8 VCR female. Confirm the actual factory configuration before ordering or connecting the instrument.

05 | Thermal Management & Temperature Compensation

The internal heating system maintains the sensing element at 100°C. This controlled thermal environment supports measurement stability under changing process conditions.

Controlled Sensor Temperature 100°C
Ambient Operating Temperature 15–50°C
Warm-Up Time 2 hours for ranges from 1 to 25,000 Torr
Warm-Up Below 1 Torr 4 hours
Zero Temperature Coefficient 0.002% FS/°C for 1–25,000 Torr
Zero Coefficient, 0.1 and 0.25 Torr 0.01% FS/°C
Zero Coefficient, 0.05 Torr 0.02% FS/°C
Span Temperature Coefficient 0.02% of Reading/°C

Temperature compensation values depend on the selected pressure range. The 1000 Torr configuration uses the 0.002% FS/°C zero coefficient.

06 | Electrical Connection & Signal Architecture

Input Power ±15 VDC ±5%
Maximum Current 0.60 A
Analog Output 0 to +10 VDC
Output Load Greater than 10 kΩ
Electrical Connector 15-pin D-sub
Connector Locking Thread-locking screws
Integrated Relay Outputs None
Pressure Signal Analog voltage output

The instrument provides an analog pressure signal without integrated relay trip points. Connect it to a compatible analog input module.

Check the receiving input impedance before commissioning. The load must exceed 10 kΩ for the specified output condition.

07 | Optional Indicators & Semiconductor Switches

The 628H product family offers optional status indicators and semiconductor switch functions. These options are separate from the standard configuration described for the 628H13TDE1B.

Optional Function Operation
Temperature Status Switch turns ON when the instrument reaches operating temperature
Temperature LED Green when the sensor reaches temperature
Heater Status Switch turns OFF when heater failure occurs
Heater LED Green during normal operation; blinking red during heater failure
Maximum Switch Current 120 mA
Maximum ON Resistance 20 Ω at 120 mA and 50°C
Maximum Open-Circuit Voltage 28 V

The supplied 628H13TDE1B configuration specifies no heater status LED. Confirm optional switches and indicators separately when the application requires external status monitoring.

08 | Process Connection & Mechanical Construction

Wetted Material Inconel
Internal Volume 6.3 cc
Specified Fitting NW16 ISO-KF
Alternative Fitting Options 1/2-inch OD tube, 8 VCR female, 8 VCO female, NW25 KF, 1.33-inch OD CF, 2.75-inch OD CF
Body Diameter 3.15 in (80.0 mm)
Body Height 3.87 in (98.4 mm)
Stem Length 1.38 in (35.1 mm)

The Inconel wetted construction supports demanding process gas measurement environments. The compact housing simplifies installation in space-constrained equipment.

Evaluate fitting geometry before selecting replacement hardware. NW16 ISO-KF and 8 VCR connections require different mating components.

09 | Pressure Limits & Mechanical Protection

Overpressure Limit 45 psia (310 kPa) or 120% FS, whichever is greater
Full-Scale Pressure 1000 Torr
Internal Volume 6.3 cc

The overpressure specification defines a protection limit, not a normal operating target. Avoid pressure spikes beyond the specified limit.

For a 1000 Torr configuration, the stated 45 psia threshold exceeds 120% of full scale. Design pressure protection around the applicable manufacturer rating.

10 | Installation & Commissioning Recommendations

Mechanical Preparation

  1. Verify the 1000 Torr full-scale configuration.
  2. Confirm vertical calibration requirements.
  3. Check the actual fitting against the installation drawing.
  4. Inspect the sealing surfaces and vacuum connection.
  5. Confirm process gas compatibility with Inconel.
  6. Allow sufficient clearance around the heated body.

Electrical Preparation

  1. Provide a regulated ±15 VDC power supply.
  2. Verify the voltage polarity and ±5% tolerance.
  3. Secure the 15-pin D-sub connector.
  4. Connect the analog output to a compatible voltage input.
  5. Check the receiving impedance above 10 kΩ.

Startup and Calibration Checks

  1. Power the instrument and allow two hours for warm-up.
  2. Maintain stable ambient conditions within 15–50°C.
  3. Verify the vertical installation orientation.
  4. Check zero output under suitable reference conditions.
  5. Compare pressure readings against a calibrated reference.
  6. Record baseline readings for future maintenance comparisons.

11 | Maintenance & Application Troubleshooting

  • Zero Shift: Check thermal stabilization, mounting orientation, and reference pressure conditions.
  • Signal Saturation: Verify actual pressure and analog input scaling.
  • Slow Startup: Allow the specified warm-up period before evaluating measurement performance.
  • Vacuum Leakage: Inspect the KF or VCR mating surfaces and sealing components.
  • Unexpected Pressure Changes: Check chamber pressure behavior and process-line isolation.

Use a traceable pressure reference during calibration verification. Avoid changing the instrument's calibration without approved service procedures.

12 | Typical Industrial & Semiconductor Applications

  • Semiconductor Process Chambers: Absolute pressure monitoring in controlled manufacturing environments.
  • Vacuum Systems: Pressure measurement in vacuum equipment and process lines.
  • Thin-Film Processing: Pressure feedback for deposition equipment.
  • Thermal Processing: Pressure monitoring in elevated-temperature manufacturing systems.
  • Gas Delivery Equipment: Pressure measurement in compatible gas distribution assemblies.

The 100°C heated sensor design supports applications requiring controlled sensing temperature. Engineers should verify gas compatibility, pressure limits, and fitting configuration before installation.

13 | Compliance & Package Verification

Compliance

  • CE compliant according to the supplied product specification.

Package Contents

  • 1 × MKS Instruments 628H13TDE1B Heated Baratron Pressure Transducer.
  • Product identification and model information.
  • Applicable technical documentation, subject to order confirmation.

Confirm cables, mounting accessories, connection adapters, and optional indicators separately. Do not assume optional accessories are included in the standard package.

14 | Professional FAQ: Engineering Selection & Field Application

Q1: Why does vertical calibration matter when installing this pressure transducer?

Calibration orientation defines the instrument's specified reference position. A different mounting position may introduce measurement deviations. Maintain the vertical orientation unless the manufacturer approves another configuration.

Q2: How should engineers interpret the overpressure protection specification?

The instrument uses the greater value between 45 psia and 120% of full scale. This rating does not authorize continuous operation at the protection limit. Use suitable pressure regulation and isolation devices.

Q3: Is the 628H13TDE1B suitable for applications requiring pressure alarm relays?

The specified configuration provides analog output only. It has no integrated relay trip points. Use an external pressure controller or PLC to implement alarm thresholds and interlocks.

Q4: When should buyers select a 1000 Torr range instead of a 100 Torr range?

Review the maximum expected chamber pressure and normal operating window. A 100 Torr range provides a smaller full-scale measurement span. A 1000 Torr range accommodates higher pressure conditions. Select a range that balances measurement requirements and process operating limits.

Q5: What should maintenance engineers record during periodic performance checks?

Record zero readings, reference pressure comparisons, ambient temperature, and startup time. Also document the supply voltage and analog output condition. Historical measurements help identify gradual drift and installation-related problems.

Global PLC Spare HUB | Industrial Instrumentation Supply

Global PLC Spare HUB supports industrial automation and semiconductor equipment sourcing. Our team assists with product identification and configuration verification.

  • 12-Month Warranty: Coverage according to confirmed sales terms.
  • Technical Assistance: Support with model identification and interface verification.
  • International Shipping: FedEx, UPS, and DHL options.
  • Dispatch Arrangement: Typically 24–48 hours, subject to stock confirmation and order processing.

Request a Quote for MKS 628H13TDE1B

Looking for the MKS Instruments 628H13TDE1B? Contact Global PLC Spare HUB with your required quantity and installation details. Our team can assist with technical verification and quotation arrangements.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.