627H.1TBD2B MKS 600 Series 0.1 Torr Precision Vacuum Sensor
Manufacturer: MKS Instruments
Product No.: 627H.1TBD2B
Condition: In stock
Product Type: Vacuum Sensor
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
MKS 627H.1TBD2B – Heated Baratron Vacuum Pressure Transducer
In low-pressure vacuum systems, thermal stability directly affects measurement consistency. The MKS Instruments 627H.1TBD2B addresses this requirement through a temperature-controlled Baratron sensing assembly.
This model belongs to the MKS 627H Series (600 Series). It provides absolute pressure measurement with a 0.1 Torr full-scale range. Its internal sensor maintains a controlled temperature of 45°C.
The heated sensing design helps reduce measurement variations caused by changes in sensor temperature. A built-in heater status LED provides a convenient visual indication of heater operation.
With vertical calibration, an analog 0–10 VDC output, and an 8 VCR female process connection, this transducer supports precision vacuum monitoring in semiconductor and industrial process equipment.
01 | Measurement Architecture
| Technical Element | Specification | Engineering Significance |
|---|---|---|
| Manufacturer | MKS Instruments | Industrial vacuum measurement technology |
| Model | 627H.1TBD2B | Specific ordering configuration |
| Product Family | 627H Series | Heated Baratron product family |
| Product Series | 600 Series | Vacuum pressure measurement platform |
| Measurement Technology | Baratron Capacitance Manometer | Capacitance-based pressure measurement |
| Measurement Type | Absolute Pressure | Measures pressure relative to an internal vacuum reference |
| Full-Scale Range | 0.1 Torr | Designed for low-pressure vacuum monitoring |
| Sensor Temperature | 45°C controlled | Stabilizes the sensing assembly temperature |
| Calibration Orientation | Vertical | Requires the specified calibration orientation |
| Warm-Up Time | 4 hours | Allows thermal stabilization before precision measurements |
| Heater Status Indicator | LED | Provides local heater operating status indication |
02 | Measurement Performance
The 627H.1TBD2B combines a low-pressure measurement range with defined accuracy and resolution specifications.
| Performance Parameter | Value |
|---|---|
| Full-Scale Pressure | 0.1 Torr |
| Measurement Accuracy | 0.12% of Reading |
| Accuracy Components | Includes non-linearity, hysteresis, and non-repeatability |
| Resolution | 0.001% of Full Scale |
| Equivalent Resolution | 0.000001 Torr |
| Zero Temperature Coefficient | 0.005% FS/°C |
| Span Temperature Coefficient | 0.02% of Reading/°C |
| Sensor Temperature | 45°C controlled |
| Warm-Up Requirement | 4 hours |
Engineering Note: Accuracy and resolution describe different measurement characteristics. Resolution indicates the smallest specified measurement increment. It does not represent absolute measurement accuracy.
03 | Electrical Interface and Signal Integration
The transmitter provides a voltage output for compatible vacuum monitoring and process control systems.
| Electrical Parameter | Specification |
|---|---|
| Supply Voltage | ±15 VDC, ±5% |
| Maximum Current | 0.25 A |
| Analog Output | 0 to +10 VDC |
| Output Load | Greater than 10 kΩ |
| Electrical Connector | 15-pin D-sub |
| Connector Retention | Thread-locking hardware |
| Trip Point Outputs | Not provided |
| Heater Status | Visual LED indicator |
Signal Integration Considerations:
- Use a compatible ±15 VDC power supply.
- Verify the analog input range before connecting the output.
- Maintain an input impedance above 10 kΩ.
- Check the 15-pin D-sub connector pin assignments.
- Provide suitable cable shielding and grounding practices.
- Do not configure external trip functions through this analog-only output.
04 | Process Connection and Mechanical Design
The process interface and wetted construction support integration into clean vacuum systems.
| Mechanical Parameter | Specification |
|---|---|
| Process Fitting | 8 VCR Female |
| Wetted Material | Inconel |
| Internal Volume | 6.3 cc |
| Overpressure Limit | 45 psia (310 kPa) or 120% F.S., whichever is greater |
| Body Diameter | 3.15 in (80.0 mm) |
| Body Height | 3.87 in (98.4 mm) |
| Stem Length | 1.38 in (35.1 mm) |
| Compliance | CE compliant |
Mechanical Selection Note: Confirm the 8 VCR female connection before ordering. Check the available installation clearance against the 80.0 mm body diameter and 98.4 mm body height.
05 | Thermal Management and Operating Environment
The heated sensor maintains its sensing temperature at 45°C. This design helps control temperature-related measurement drift.
| Environmental Parameter | Specification |
|---|---|
| Operating Temperature | 15 to 40°C |
| Controlled Sensor Temperature | 45°C |
| Zero Temperature Coefficient | 0.005% FS/°C |
| Span Temperature Coefficient | 0.02% of Reading/°C |
| Heater Indication | LED |
| Thermal Warm-Up | 4 hours |
Important: The 45°C value describes the controlled sensor temperature. The specified ambient operating range remains 15–40°C.
06 | Installation and Commissioning Procedure
Proper installation preserves the calibration conditions and protects the low-pressure sensing assembly.
- Verify Orientation: Install the instrument according to its vertical calibration specification.
- Inspect the Process Port: Check the 8 VCR female fitting for contamination or mechanical damage.
- Prepare the Vacuum Line: Ensure the connection surfaces meet the process cleanliness requirements.
- Secure the Connection: Use compatible VCR hardware and approved installation procedures.
- Connect Power: Apply the specified ±15 VDC supply within its tolerance.
- Wire the Output: Connect the 0–10 VDC signal to a compatible analog input.
- Verify Loading: Maintain an output load above 10 kΩ.
- Allow Warm-Up: Wait four hours before relying on precision readings.
- Check Heater Status: Inspect the heater status LED during startup.
- Validate the Reading: Compare the output with an appropriate calibrated pressure reference.
07 | Maintenance and Troubleshooting Insights
- Unstable Readings: Check the warm-up period, power stability, grounding, and analog input loading.
- Zero Offset: Verify the reference pressure and calibration conditions before adjusting the system.
- Slow Stabilization: Confirm the heater status and allow the complete four-hour warm-up.
- Unexpected Pressure Values: Inspect the process connection and verify the instrument's measurement range.
- Output Problems: Check the ±15 VDC supply and 15-pin connector wiring.
- Installation-Related Drift: Confirm the vertical calibration orientation and mounting arrangement.
Maintenance Recommendation: Avoid opening the sensing assembly or changing internal calibration settings without authorized procedures. Use suitable reference equipment for periodic verification.
08 | Application and System Compatibility
The MKS 627H.1TBD2B suits vacuum applications that require low-pressure absolute measurement and a heated sensing assembly.
- Semiconductor process vacuum monitoring
- Thin-film deposition equipment
- Vacuum chamber pressure measurement
- Precision gas process monitoring
- Industrial vacuum instrumentation
- Vacuum control and data acquisition systems
System Integration Checklist:
- Analog input must accept 0–10 VDC.
- Power supply must provide ±15 VDC.
- Analog input impedance must exceed 10 kΩ.
- Mechanical connections must match 8 VCR female fittings.
- Installation must respect the vertical calibration condition.
- Ambient temperature must remain within 15–40°C.
09 | Product Compliance and Documentation
- CE Compliance: The specified model carries CE compliance.
- Electrical Configuration: ±15 VDC power and 0–10 VDC analog output.
- Process Materials: Inconel wetted construction.
- Calibration Configuration: Vertical calibration.
Request the applicable product declaration and supporting technical documents when your project requires formal compliance verification.
10 | Five Engineering FAQs
Q1: Why does a heated Baratron use a 45°C sensor temperature instead of ambient temperature?
A: Temperature changes can affect the mechanical and electrical characteristics of a capacitance sensing assembly. Controlled heating helps maintain consistent thermal conditions and reduces temperature-related measurement variations.
Q2: How should engineers scale the 0–10 VDC output in a PLC or data acquisition system?
A: Use the instrument's 0.1 Torr full-scale range as the scaling reference. A linear 0–10 V mapping corresponds to 0–0.1 Torr. Confirm the transfer function and polarity against the applicable manufacturer documentation before commissioning.
Q3: What happens if the gauge operates before completing its four-hour warm-up?
A: The sensor may not reach its specified thermal equilibrium. Early readings may therefore differ from stabilized measurements. Allow the full warm-up period before conducting calibration checks or process qualification.
Q4: Why is vertical calibration important when replacing an existing vacuum transducer?
A: Installation orientation can affect the relationship between the sensor's calibrated condition and its installed operating condition. A replacement should preserve the specified vertical orientation whenever practical. Verify zero performance after installation.
Q5: How can engineers distinguish a gauge fault from a vacuum system problem?
A: Compare the gauge output with an independent calibrated reference. Check the power rails, analog input loading, warm-up status, and process connection. If both instruments show similar pressure changes, investigate the vacuum system before replacing the transducer.
11 | Ordering and Supply Information
For accurate model selection, provide the complete ordering number and installation requirements when requesting a quotation.
| Ordering Information | Details |
|---|---|
| Manufacturer | MKS Instruments |
| Part Number | 627H.1TBD2B |
| Series | 627H / 600 Series |
| Product Type | Heated Baratron Absolute Pressure Transducer |
| Full-Scale Range | 0.1 Torr |
| Output | 0–10 VDC |
| Process Connection | 8 VCR Female |
| Warranty | 12 months |
| Shipping Options | FedEx, DHL, UPS |
Contact us for a quotation, delivery information, and technical assistance. Our team can help verify the model, electrical interface, pressure range, and process connection before ordering.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



