5301-MBP-DFCM ProSoft Modbus Plus to DF1 Protocol Gateway
Manufacturer: GE Fanuc
Product No.: 5301-MBP-DFCM
Condition: In stock
Product Type: Protocol Gateway Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
5301-MBP-DFCM ProSoft 5301 Modbus Plus to DF1 Protocol Gateway
The 5301-MBP-DFCM is a standalone DIN-rail protocol converter engineered by ProSoft Technology to bridge Modbus Plus peer-to-peer networks with Allen-Bradley DF1 serial devices. Featuring integrated Server support, this gateway links ControlLogix, CompactLogix, SLC 500, and PLC-5 processors directly to legacy Modbus Plus infrastructure without requiring chassis backplane slots.
Built with 2500V RMS optical port isolation and configurable RS-232/422/485 serial interfaces, the 5301-MBP-DFCM delivers deterministic data exchange in oil and gas, electrical substations, food processing, and discrete manufacturing lines.
Architecture & Protocol Bridge Topology
-
Base Module Family (5301): Standalone DIN-Rail Industrial Protocol Gateway Series
- Network Side (MBP): High-speed Modbus Plus interface with built-in Server capability
- Serial Side (DFCM): Configurable DF1 Full/Half-Duplex Master or Slave driver
Hardware & Electrical Specifications
| Subsystem | Parameter | Verified Technical Specification |
|---|---|---|
| Identification | Brand & Model | ProSoft Technology 5301-MBP-DFCM (5301 Series) |
| Power Supply | Input Voltage & Current | 24 VDC nominal (18 to 36 VDC allowed); 500 mA max @ 24 VDC; Positive, Negative, GND terminals |
| Application Serial Ports | Physical Layer | RS-232 / RS-422 / RS-485; configurable RS-232 handshaking; screw termination included |
| Galvanic Isolation | Dielectric Protection | 2500V RMS port signal isolation (UL 1577); 3000V DC min port-to-ground and logic power |
| Configuration Port | Diagnostics Interface | DB-9M RS-232 only (no hardware handshaking) for ProSoft Configuration Builder |
| Status Diagnostics | LED Indicators | Power, Module Status, Application Status, Serial Port Activity, and Error LEDs |
| Thermal & Humidity | Environmental Limits | -20°C to 50°C (-4°F to 122°F) operating; -40°C to 85°C storage; 5% to 95% RH non-condensing |
| Physical Dimensions | Standard vs. Extended | Standard: 5.20 × 2.07 × 4.52 in (13.2 × 5.25 × 11.48 cm); Extended: 5.20 × 2.73 × 4.52 in |
Standard Factory Accessory Kit
- Serial Interconnects: Mini-DIN to DB-9M serial cables and a 4-foot RS-232 configuration cable.
- Terminal Adapters: RS-422/485 DB-9 to Screw Terminal Adaptor(s) matched to port count.
- Commissioning Tools: 2.5 mm flat-blade terminal screwdriver and software/documentation CD.
Field Engineering FAQ & Commissioning Guidance
-
Q: How does internal database memory exchange data between Modbus Plus nodes and DF1 serial controllers?
A: The gateway maps both protocols into a shared internal register database, decoupling asynchronous serial polling rates from deterministic token-passing network scans.
-
Q: Why is 2500V RMS port isolation critical when linking legacy PLC-5 or SLC 500 processors across separate buildings?
A: Ground potential differences between distant electrical panels create destructive ground loops; galvanic isolation prevents transient surges from damaging serial UART transceivers.
-
Q: What serial handshaking setting should engineers select when connecting to an Allen-Bradley DF1 Full-Duplex port?
A: Disable hardware handshaking (RTS/CTS) for standard three-wire point-to-point links, or enable CTS control when interfacing through radio modems or line drivers.
-
Q: How can technicians quickly isolate communication faults between the Modbus Plus trunk and the DF1 field device?
A: Observe the separate Serial Activity/Error LEDs alongside the Application Status LED, and connect via the dedicated DB-9M configuration port to inspect live diagnostic counters.
-
Q: What power supply sizing margin is recommended when installing multiple gateways inside a compact NEMA enclosure?
A: Budget at least 12 W (500 mA at 24 VDC) per unit plus 20% headroom, and maintain airflow clearance to keep internal cabinet ambient temperatures below 50°C.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.