Home 1746-NO8V Rockwell Automation SLC 500 Voltage Output Module

1746-NO8V Rockwell Automation SLC 500 Voltage Output Module

  • Manufacturer: Allen-Bradley

  • Product No.: 1746-NO8V

  • Condition: In stock

  • Product Type: Analog Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 540g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

1746-NO8V | Precision Analog Voltage Output for SLC 500

The Allen-Bradley 1746-NO8V is an eight-channel analog voltage output module for the SLC 500 automation platform. It converts digital controller data into precise analog voltage signals for industrial equipment.

Each channel provides configurable voltage output ranges, including ±10.25 VDC, ±10 VDC, 0–10 VDC, 0–5 VDC, and 1–5 VDC. Its 16-bit digital-to-analog conversion delivers a resolution of 320 µV/count.

The module uses an R-2R ladder digital-to-analog conversion architecture. This design supports accurate analog command generation for modulating equipment and process control devices.

Typical applications include variable frequency drives, modulating valves, dampers, louvers, and other equipment with voltage reference inputs. Engineers can configure individual channels for different data formats and output behaviors.

01 | Product Identification & Hardware Specifications

Manufacturer Rockwell Automation
Brand Allen-Bradley
Model / Catalog Number 1746-NO8V
Product Series SLC 500
Module Type Analog Voltage Output Module
Output Configuration 8 single-ended channels
Conversion Method R-2R Ladder DAC
Resolution 16-bit, 320 µV/count
Output Coding -32,768 to +32,767
Output Voltage Ranges -10 to +10 VDC; -10.25 to +10.25 VDC; 0–10 VDC; 0–5 VDC; 1–5 VDC
Overall Accuracy at 25°C 0.1% of full scale
Overall Accuracy at 60°C 0.2% of full scale
Maximum Accuracy Drift ±33 ppm/°C of full scale
Gain Error 0.15%
Offset Drift ±0.53 LSB/°C
Load Resistance 1 kΩ minimum
Maximum Load Current 10 mA
Output Impedance Less than 1 Ω
Output Overrange 2.5% at ±10.25 V range
Backplane Current at 5 VDC 120 mA
Backplane Current at 24 VDC 160 mA with J4 set to RACK; 0 mA with J4 set to EXT
Backplane Power Consumption 5.6 W
External Power Supply Optional 24 VDC source
Compatible Chassis 1746 chassis, excluding slot 0
Isolation Test Voltage 500 VDC, as specified in supplied data
Operating Temperature 0–60°C
Relative Humidity 5–95%, non-condensing
Operating Shock 30 G
Vibration Resistance 5 G at 10–500 Hz
Certifications cUL and CE; Class I, Division 2 suitability stated in supplied data
UPC 10781180054577

02 | Analog Conversion & Signal Quality

The 1746-NO8V converts digital values into continuous voltage references. Its conversion resolution and accuracy directly influence downstream equipment control.

Digital-to-Analog Conversion

  • 16-bit Resolution: Provides 65,536 possible digital code values.
  • 320 µV/count: Defines the nominal voltage increment specified for the module.
  • R-2R Ladder Architecture: Converts digital codes into corresponding analog voltage levels.
  • Signed Output Coding: Supports positive and negative output values.
  • Five Output Ranges: Accommodates different voltage reference requirements.

Accuracy Across Temperature

The specified overall accuracy changes with operating temperature.

  • At 25°C, overall accuracy is 0.1% of full scale.
  • At 60°C, overall accuracy is 0.2% of full scale.
  • Maximum overall accuracy drift reaches ±33 ppm/°C of full scale.
  • Offset drift reaches ±0.53 LSB/°C.

These values matter when engineers use analog references for precision positioning or process regulation. Consider temperature-related drift during calibration and control loop validation.

03 | Channel Configuration & Data Processing

Each of the eight output channels supports configurable data representation. This flexibility allows the controller to match application engineering units and control requirements.

Data Format Engineering Purpose
Scaled Engineering Units Maps digital values to application-specific engineering ranges.
Scaled for PID Supports analog command generation within PID control applications.
Proportional Counts Uses proportional digital values for analog output scaling.
1746-NO4 Format Provides an alternative data representation for supported configurations.
User-Defined Scale Allows application-specific scaling limits.

Additional Output Parameters

  • User-defined scaling limits.
  • Output clamping limits.
  • Output alarm limits.
  • Ramp rate and ramp limits.
  • Preset fault values.
  • Fault behavior selection: reset, hold, or preset.
  • Latched alarm operation.
  • Latched alarm reset.

These configuration options help engineers manage output transitions and abnormal operating conditions. They also support more predictable interactions with connected equipment.

04 | Response Characteristics & Timing

Output timing affects how quickly connected equipment responds to controller commands. Engineers should distinguish channel update time from analog output step response.

  • Published Update Time: 540 µs per eight-channel update in the supplied specification.
  • Additional Update References: The supplied description also reports 5 ms and 10 ms for eight-channel updates under different operating classes.
  • Step Response: The supplied information lists 1 ms, 2.5 ms, and 60 ms under different response descriptions.

Technical Verification Required: These timing figures are inconsistent across the supplied source descriptions. Confirm the applicable update and step-response definitions using the official hardware manual before designing time-critical control loops.

05 | Field Wiring & Load Matching

The module uses eight single-ended voltage outputs. Each channel requires suitable field wiring and a compatible receiving device.

Electrical Load Requirements

  • Minimum recommended load resistance: 1 kΩ.
  • Maximum load current: 10 mA.
  • Output impedance: less than 1 Ω.
  • Selectable output ranges depend on the connected equipment requirements.

Installation Procedure

  1. Verify the Chassis: Confirm compatibility with the 1746 platform.
  2. Select the Slot: Use an available slot other than slot 0.
  3. Check Power Requirements: Verify backplane loading and external 24 VDC requirements.
  4. Review J4 Configuration: Confirm the RACK or EXT jumper position before wiring.
  5. Inspect Field Connections: Check output terminals, cable condition, and signal return paths.
  6. Verify Load Resistance: Confirm that each receiving device meets the minimum resistance requirement.
  7. Configure Output Ranges: Match the voltage range to the connected equipment.
  8. Complete Grounding: Follow the system grounding and shielding instructions.
  9. Validate Signals: Measure output voltage during controlled commissioning.

Engineering Note: Single-ended wiring requires careful attention to signal reference and grounding. Avoid unnecessary ground loops and follow the manufacturer's terminal wiring diagrams.

06 | Application Engineering & Equipment Integration

The 1746-NO8V provides voltage references for industrial devices that accept analog command signals.

Equipment Typical Control Application
Variable Frequency Drives Speed reference and frequency command generation.
Modulating Valves Valve position reference and process flow regulation.
Industrial Dampers Position control for airflow and ventilation systems.
Louvers Adjustable opening and position control.
Analog Actuators Voltage-based positioning and command signals.

Before connecting a device, verify its input voltage range, input impedance, signal reference, and electrical isolation requirements.

07 | Diagnostics, Calibration & Preventive Maintenance

Stable analog output depends on correct scaling, wiring, power supply conditions, and load characteristics.

  • Voltage Verification: Compare measured output against the commanded engineering value.
  • Channel Comparison: Test channels under identical reference conditions to identify abnormal deviations.
  • Scaling Inspection: Check raw counts, engineering units, and configured output limits.
  • Temperature Monitoring: Consider the specified accuracy variation across the operating range.
  • Load Inspection: Check receiving device impedance and field wiring condition.
  • Alarm Review: Verify output clamping, alarm limits, and fault response settings.
  • Power Inspection: Check chassis loading and external supply configuration.

Practical Calibration Tip: Use a calibrated digital multimeter to measure representative output channels. Test zero, intermediate, and full-scale commands. Record the measured values for future maintenance comparisons.

08 | Environmental Ratings & Compliance

The supplied specifications identify the following environmental operating conditions:

  • Temperature: 0–60°C.
  • Humidity: 5–95% non-condensing relative humidity.
  • Shock: 30 G operating shock rating.
  • Vibration: 5 G across 10–500 Hz.
  • Isolation: 500 VDC isolation test value stated in the supplied information.
  • Compliance: cUL and CE certification references.
  • Hazardous Location: Class I, Division 2 suitability stated in the supplied information.

Verify the applicable certification markings and installation conditions against the product label and official Rockwell Automation documentation. Environmental ratings do not replace enclosure or installation requirements.

09 | Compatibility & Replacement Selection

The 1746-NO8V belongs to the Allen-Bradley SLC 500 analog output product family.

Before selecting this module, check the following engineering requirements:

  • Confirm the installed SLC 500 controller and 1746 chassis.
  • Verify that the selected slot is not slot 0.
  • Check whether the application requires voltage or current output.
  • Confirm the number of required analog output channels.
  • Match the output voltage range to the field device.
  • Verify the external power and J4 jumper configuration.
  • Review the existing PLC program's data format and scaling.
  • Confirm terminal wiring and grounding requirements.

Replacement Advice: Do not substitute a current-output module solely because its catalog number belongs to the same SLC 500 family. Voltage and current interfaces require different field connections and configuration.

10 | Five Professional Engineering FAQs

Q1: How should engineers select the correct voltage range for a connected VFD?

First, inspect the drive's analog reference input specification. Confirm its accepted voltage range and signal common arrangement. Then configure the corresponding output range in the PLC application. Validate the minimum and maximum frequency commands during commissioning.

Q2: Why might the measured voltage differ slightly between two output channels?

Channel differences can result from conversion accuracy, temperature drift, wiring resistance, and measurement instrument accuracy. Compare both channels under identical load conditions. Check calibration records before replacing the module.

Q3: How can output ramp configuration improve valve positioning?

A controlled ramp limits abrupt changes in the analog command. This can reduce sudden actuator movement and process disturbances. Select ramp parameters according to actuator response characteristics and process safety requirements.

Q4: What should engineers investigate when an analog signal becomes unstable?

Inspect the field cable, signal reference, grounding, and receiving device first. Check external supply stability and configured output limits. Measure the signal directly at the module and equipment terminals to isolate the source.

Q5: When is a dedicated analog output module preferable to a digital output module?

Use analog outputs when equipment requires continuously variable commands rather than simple ON/OFF switching. Examples include speed references, valve positioning, and damper control. Verify the receiving device's signal interface before selecting the module.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.