Home 1734-IE2C | Allen-Bradley POINT I/O Current Input Module

1734-IE2C | Allen-Bradley POINT I/O Current Input Module

  • Manufacturer: Allen-Bradley

  • Product No.: 1734-IE2C

  • Condition: In stock

  • Product Type: Analog Input Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 540g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

01 | Product Overview – Analog Signal Acquisition

The 1734-IE2C is a two-channel analog current input module from Allen-Bradley POINT I/O. Rockwell Automation designed this module for distributed industrial signal acquisition.

It converts field current signals into digital values for PLC processing. Each channel supports 0–20 mA and 4–20 mA input ranges. Its 16-bit Delta-Sigma converter provides 0.32 μA/count resolution across 0–21 mA.

The module uses two single-ended, non-isolated input channels. It connects to the POINT I/O system through a compatible terminal base. A communication adapter links the I/O assembly to the controller network.

Its compact 12 mm module width supports high-density distributed I/O installations. Engineers can install it horizontally or vertically on a standard 35 mm DIN rail.

02 | Technical Data – Electrical and Mechanical Parameters

Manufacturer Rockwell Automation
Brand Allen-Bradley
Model / Catalog Number 1734-IE2C
Product Family 1734 POINT I/O
Module Type Analog Current Input Module
Number of Channels 2 single-ended channels
Channel Isolation Non-isolated
Input Signal 0–20 mA / 4–20 mA
Conversion Resolution 16 bits
Resolution per Count 0.32 μA/count over 0–21 mA
Conversion Method Delta-Sigma
Data Format Signed Integer
Absolute Accuracy 0.1% Full Scale at 25°C
Accuracy Drift 30 ppm/°C
Factory Calibration Factory calibrated
External Supply Voltage 10–28.8 VDC
Nominal Supply 24 VDC
Current Draw 75 mA at 5 VDC
Power Dissipation 0.6 W at 28.8 VDC
Thermal Dissipation 2.0 BTU/hour at 28.8 VDC
Maximum Overload Protection 28.8 VDC
Continuous Isolation Voltage 50 V
Dielectric Withstand 2550 VDC for 60 seconds
Input Step Response 8–80 ms, depending on notch setting
Module Update Rate 12–120 ms, depending on notch setting
Dimensions 56 × 12 × 75.5 mm
Approximate Weight 0.036 kg
Enclosure Rating Open-style
Keyswitch Position Position 3
Mounting Method 35 mm DIN rail

03 | Analog Conversion Performance

The module uses Delta-Sigma analog-to-digital conversion. This architecture converts field current into signed integer data for controller processing.

Conversion Characteristics

  • 16-Bit Resolution: Provides detailed digital representation of analog current signals.
  • 0.32 μA/Count: Defines the stated resolution across the 0–21 mA conversion range.
  • Factory Calibration: Reduces the need for initial field calibration.
  • 0.1% Full-Scale Accuracy: Applies at an ambient reference temperature of 25°C.
  • 30 ppm/°C Drift: Describes the specified accuracy variation with temperature.
  • Signed Integer Output: Provides digital values for PLC logic and process calculations.

Resolution and accuracy describe different performance characteristics. Engineers should consider both when evaluating measurement quality.

04 | Filter Configuration and Response Performance

The input notch setting affects channel response and overall module update time. Select the filter frequency according to signal stability and control response requirements.

Notch Frequency Input Step Response Module Update Rate
50 Hz 80 ms 120 ms
60 Hz (Default) 70 ms 100 ms
250 Hz 16 ms 24 ms
500 Hz 8 ms 12 ms

Engineering Selection:

  • Use lower notch frequencies when stronger rejection of power-line interference is required.
  • Consider higher notch frequencies when faster signal response is important.
  • Evaluate process noise before changing the default 60 Hz setting.
  • Check the module update rate when calculating PLC control-loop timing.

05 | Field Wiring and Terminal Base Architecture

The 1734-IE2C requires a compatible POINT I/O terminal base. The terminal base provides the physical wiring interface and electrical connections.

Supported Terminal Base Assemblies

  • 1734-TB
  • 1734-TBS
  • 1734-TOP
  • 1734-TOPS

Recommended Field Wiring

  • Wire size: 22–14 AWG.
  • Conductor type: Solid or stranded copper.
  • Wire construction: Shielded copper recommended.
  • Temperature rating: 167°F (75°C) or higher.
  • Keyswitch setting: Position 3.

Each channel accepts a configured current input signal. Because the channels are non-isolated, engineers must evaluate common-reference wiring and grounding arrangements carefully.

06 | Installation and Commissioning Procedure

  1. Disconnect field and system power before installation.
  2. Confirm the POINT I/O assembly configuration.
  3. Install the compatible terminal base on the DIN rail.
  4. Set the terminal base keyswitch to position 3.
  5. Align the 1734-IE2C with the terminal base.
  6. Secure the module according to the installation instructions.
  7. Connect the two current signal channels.
  8. Verify field polarity and common-reference wiring.
  9. Connect the required communication adapter.
  10. Restore power and inspect module status indicators.
  11. Configure channel ranges and filter settings.
  12. Compare PLC readings with a calibrated current source.

Mounting Flexibility: The module supports horizontal and vertical installation. Maintain suitable cabinet spacing and follow the manufacturer's thermal requirements.

07 | Controller and Network Integration

The module operates within the distributed POINT I/O architecture. A compatible communication adapter transfers I/O data between the module assembly and the controller.

Controller Platforms Compatible Allen-Bradley controller systems
Common Applications CompactLogix and ControlLogix architectures
I/O Family 1734 POINT I/O
Communication Options EtherNet/IP, DeviceNet, and ControlNet through suitable adapters
Installation Interface Compatible POINT I/O terminal base

Compatibility Note: Network compatibility depends on the selected communication adapter. Verify adapter catalog numbers, controller support, firmware revisions, and system configuration before integration.

08 | Maintenance and Signal Diagnostics

Accurate troubleshooting requires checking the complete measurement path, not just the I/O module.

  • Signal Verification: Apply a known current source and compare the PLC reading.
  • Wiring Inspection: Check terminal tightness, polarity, shielding, and common connections.
  • Channel Comparison: Apply the same test current to both channels and compare their readings.
  • Filter Assessment: Review notch frequency when readings appear unstable or delayed.
  • Scaling Verification: Check PLC engineering-unit conversion and raw integer values.
  • Temperature Assessment: Consider the specified 30 ppm/°C accuracy drift.
  • Network Diagnostics: Check adapter status and I/O connection health.

09 | Environmental Ratings and Compliance

  • Enclosure: Open-style construction.
  • Operating Temperature: Confirm the rated range in the official installation manual.
  • Humidity: Follow the manufacturer's environmental specifications.
  • EMC: Follow recommended shielding, grounding, and wiring practices.
  • Isolation: 50 V continuous isolation voltage, as specified.
  • Dielectric Withstand: 2550 VDC for 60 seconds, as specified.
  • Certifications: Verify applicable approvals using the product label and official documentation.

Note that the two analog channels are non-isolated. The stated isolation ratings should not be interpreted as channel-to-channel isolation.

10 | Packaging and Supply Information

  • 1 × Allen-Bradley 1734-IE2C Analog Input Module.
  • Compatible terminal base: Available separately unless confirmed in the order.
  • Product Condition: New & Original in Factory Packing.
  • Warranty: Factory Warranty: 12 Months.
  • Shipping: FedEx, UPS, and DHL.
  • Order Support: Model verification and technical assistance.

11 | Engineering FAQ – Application and Selection

Q1: How should engineers select between the 0–20 mA and 4–20 mA input ranges?

Choose the range according to the field transmitter and process instrumentation standard. The 4–20 mA range provides a live-zero reference. This helps identify certain open-loop and wiring faults. The 0–20 mA range suits devices designed for zero-based current output.

Q2: Can this module directly measure two-wire loop-powered transmitters?

It can acquire compatible current-loop signals when the external loop supply and wiring meet the module requirements. Engineers must provide the appropriate loop power source. Verify the transmitter connection diagram before wiring because the channels are single-ended and non-isolated.

Q3: Why might PLC readings fluctuate even when the transmitter output remains stable?

Check grounding, shielding, shared references, and nearby switching equipment. Also inspect the selected notch frequency and the transmitter's output stability. Compare readings with a calibrated current source to isolate field-side and module-side problems.

Q4: Does 16-bit resolution guarantee 16-bit measurement accuracy?

No. Resolution describes the smallest digital conversion increment. Accuracy describes the difference between the measured and actual signal. The specified absolute accuracy is 0.1% full scale at 25°C. Engineers should evaluate accuracy, temperature drift, and system noise together.

Q5: What additional components should be included when planning a POINT I/O replacement?

Check the terminal base, communication adapter, power supply, DIN rail arrangement, and field wiring. Confirm the keyswitch position and controller configuration. Reusing an existing terminal base may simplify installation, but verify its compatibility and physical condition first.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.