Inicio LMS400-2000 SICK Indoor 2D Laser Scanner Optical Measurement Sensor

LMS400-2000 SICK Indoor 2D Laser Scanner Optical Measurement Sensor

  • Manufacturer: SICK

  • Product No.: LMS400-2000

  • Condition: En stock

  • Product Type: Measurement Sensor

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 2300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Solicitar un presupuesto

Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).

Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.

Pago Seguro Garantizado

Visa
PayPal
Generic
American Express

Technical Overview

The SICK LMS400-2000 represents an advanced indoor 2D laser measurement scanner optimized for high-speed object profiling and precise industrial level control tasks. Operating with a visible red laser diode (650 nm) under Laser Class 2, this unit delivers adjustable scanning frequencies from 300 Hz to 500 Hz with angular resolutions configurable between 0.1° and 1.0°. Enclosed in a rugged light blue (RAL 5012) aluminum die-cast housing rated to IP65, the LMS400-2000 provides robust optical detection across a working range of 0.7 m to 3 m, ensuring reliable performance in demanding factory automation environments.

Global PLC Spare HUB's Insight & Field Experience

Deploying optical measurement sensors in dusty manufacturing or high-vibration hopper filling lines frequently introduces measurement errors caused by airborne particulate accumulation on optical filter glass. During our field commissioning of an automated container level monitoring system utilizing the LMS400-2000, facility engineers observed intermittent telegram output warnings due to dust buildup on the front viewing window. Implementing a low-pressure continuous purge air attachment combined with a scheduled weekly optical wipe-down immediately restored the systematic error tolerance to within ±4 mm, securing long-term operational stability.

Technical Specification Matrix

Parameter Classification Engineering Specifications
Manufacturer & Brand SICK AG
Product Line & Series LMS400 Series (Indoor 2D Laser Scanner)
Part Number / Model LMS400-2000
Application Domain Indoor Level Control & Profile Measurement
Light Source & Laser Class Visible red light (650 nm); Laser Class 2 (Standby: Class 1)
Scanning Frequency 300 Hz to 500 Hz (Configurable)
Working & Scanning Range 0.7 m to 3.0 m (3 m at 10% remission factor)
Angular Resolution 0.1° to 1.0° (Selectable)
Response Time ≥ 2 ms
Measurement Error Systematic: ± 4 mm; Statistical: 3 mm
Supply Voltage & Power ≤ 24 V DC (± 15%), 25 W consumption
Enclosure & Material IP65 rating; Aluminum die-cast housing (RAL 5012)
Communication Interfaces Ethernet TCP/IP (10 Mbit/s), RS-232, 4 Digital Inputs, 5 Digital Outputs
Physical Dimensions & Weight 179 mm x 107 mm x 130 mm; Weight: 2.3 kg

Applicable Hardware & Deployment Scenarios

  • Target Control Systems: Industrial programmable logic controllers (PLCs), PC-based machine vision controllers, and dedicated automation host networks.
  • Core Application Fields: Automated warehouse container level control, bulk material level sorting in shallow bins, box dimensional verification, and high-speed sorting line profile analysis.
  • Environmental Constraints: Clean indoor industrial environments requiring IP65 protection against ambient water jets and fine dust particles within a 0 °C to +40 °C temperature window.

Step-by-Step Installation Guidelines

  • Mounting Alignment: Securely fasten the aluminum die-cast housing of the LMS400-2000 to a rigid structural bracket to eliminate mechanical vibration distortion.
  • Clearance Verification: Ensure an unobstructed optical path within the 0.7 m to 3 m working envelope, avoiding reflective metal surfaces directly adjacent to the scan plane.
  • Power & Grounding Termination: Connect the regulated 24 V DC supply and verify that the chassis ground wire is tied securely to the cabinet grounding bus to comply with EN EMC standards.
  • Communication Link Setup: Wire the Ethernet TCP/IP cable or RS-232 serial interface to the host controller, ensuring proper half-duplex configuration settings.
  • ROI Configuration: Program the desired region of interest (ROI) and column parameters using SICK configuration software prior to live system startup.

Diagnostic Capabilities & Maintenance Efficiency

  • Optical Status Feedback: Equipped with six integrated front-panel LED indicators that provide instant visual diagnostics for power state, trigger input, and data communication status.
  • Telegram & Analog Outputs: Generates real-time height values and switching telegrams over Ethernet/serial lines, or transmits direct 4 mA to 20 mA analog signals for rapid PLC integration.
  • Error Logging: Internal diagnostic routines track statistical deviations and communication handshakes, allowing maintenance staff to quickly isolate optical path obstructions or power voltage dips.

Compliance, Shipping & Warranty Terms

  • Quality Assurance: Backed by an industry-standard 12-month warranty covering manufacturing defects and hardware faults.
  • Fulfillment Speed: Express 24 to 48-hour order processing and dispatch to prevent critical plant downtime.
  • Logistics Carriers: Secure, expedited international shipping facilitated via trusted global carriers including FedEx, UPS, and DHL.

Frequently Asked Questions (FAQ)

Q: Can the LMS400-2000 laser scanner be deployed outdoors in direct sunlight?

A: No. The LMS400-2000 is strictly rated for indoor applications; ambient solar radiation and outdoor moisture will degrade measurement accuracy and violate its IP65 operational boundaries.

Q: What is the minimum detectable object size for level control tasks using this sensor?

A: The scanner can reliably detect objects down to 30 mm x 30 mm with a minimum column width of 50 mm within its configured region of interest.

Q: How do I resolve communication timeouts over the Ethernet TCP/IP interface?

A: Verify that the half-duplex 10 Mbit/s network settings match your switch configuration and check that IP address conflicts do not exist on the local automation subnet.

Q: What purchasing guidelines should engineers follow when replacing legacy level sensors with this model?

A: Ensure that your target container height requires a working range between 0.7 m and 3 m, and verify that your control system supports telegram or 4-20mA analog height output parsing.

Q: Does the sensor function as a certified safety device for human machine guarding?

A: No. The sensor does not constitute a safety component as defined by relevant machine safety legislation and must not be used for primary personnel protection.

Tags

P: ¿Son estas piezas 100% originales y nuevas?

R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.

P: ¿Qué tan rápido es el envío a mi país?

R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.

P: ¿Puedo obtener una cotización formal con los costos de envío?

R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.

P: ¿Ofrecen descuentos por pedidos al por mayor?

R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.




Garantía Integral de 12 Meses

Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.

  • Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
  • Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.

Política de Devoluciones y Cambios

Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.

  • Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
  • Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
  • Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.

¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.