Honeywell XNX-AMAI-RNIF1 Universal Gas Transmitter IR Propane
Manufacturer: Honeywell
Product No.: XNX-AMAI-RNIF1
Condition: En stock
Product Type: Universal Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 4400g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Product Overview
The Honeywell XNX-AMAI-RNIF1 operates as a high-performance industrial gas detector platform.
This XNX Universal Transmitter integrates seamless signal processing for combustible gas detection.
Engineered with ATEX/IEC explosion-proof certification, it features a heavy-duty painted aluminum housing.
It supports multi-bus communications and incorporates an infrared sensor tuned for 0-100% LEL propane detection.
The unit includes dedicated relay outputs for reliable industrial field alerts and safety shutoff control.
Global PLC Spare HUB's Insight
Our engineering team installed the Honeywell XNX-AMAI-RNIF1 across multiple offshore hydrocarbon loading facilities.
In high-vibration compressor stations, standard gas transmitters often trigger false alarm trips.
During a field project, the optical IR sensor maintained zero stability despite severe ambient moisture and fog.
The relay option provided instant local horn activation during emergency shutdown testing.
We recommend verifying terminal resistance during installation to ensure uninterrupted HART communication signals.
Technical Specifications
| Brand | Honeywell |
| Model Designation | XNX-AMAI-RNIF1 |
| Product Series | XNX Universal Transmitter |
| Approval Code | A = ATEX / IECEx Explosion-proof Approved |
| Cable Entry Type | M = M25 Threaded Cable Entries |
| Enclosure Material | A = LM25 Marine-Grade Painted Aluminum Enclosure |
| Personality Interface | I = Interface for Searchline Excel, Searchpoint Optima, and Generic 4-20mA inputs |
| Relay Board Option | R = Integrated Relay Board (3 Alarm/Fault Relays) |
| Local HART Interface | N = No External Local HART Port |
| Sensor Type & Target Gas | IF1 = Optical Infrared Hydrocarbon Sensor (0-100% LEL Propane) |
| Measurement Range | 0 to 100% LEL (Lower Explosive Limit) Propane |
| Frequency Response | T90 < 4 seconds (Infrared Sensor Optical Channel Response) |
| Sensitivity & Resolution | Sensitivity: ±1% LEL; Resolution: 1% LEL |
| Linearity & Accuracy | Linearity deviation < ±2% FS across full operational scale |
| Operating Temperature | -40°C to +65°C (-40°F to +149°F) |
| Environmental Endurance | IP66 rating; corrosion-resistant marine epoxy finish |
| Anti-Interference Ability | Immune to chemical poisoning, silicone contamination, and solar radiation |
| Unit Weight | 4.4 kg (9.7 lbs) |
Model Selection & Comparison
When selecting your transmitter configuration, consider your system topology and HART setup requirement:
- XNX-AMAI-RNIF1: Features built-in relay contacts for direct local alarm control without extra local HART hardware.
- XNX-AMAI-NHIF1: Includes non-relay configuration designed for centralized safety systems without local output relays.
Technical Recommendation: Choose XNX-AMAI-RNIF1 if local visual or audible beacon control is needed at the transmitter point.
Installation & Setup Guide
- Mount the enclosure securely to a structural wall or rigid pole structure.
- Verify that all M25 conduit entries utilize certified explosion-proof cable glands.
- Connect signal wiring according to standard 3-wire current loop power conventions.
- Ensure grounding straps bond the aluminum housing directly to plant ground grids.
Commissioning & Maintenance
- Access calibration settings magnetically through the toughened glass window cover.
- Perform non-intrusive target gas span checks without opening the enclosure.
- Review system health metrics using standard handheld HART communicators on signal lines.
- Replace modular internal circuit cards swiftly during field service procedures.
System Compatibility
- Directly interfaces with Honeywell Searchline Excel open path detectors.
- Fully compatible with Searchpoint Optima Plus optical point gas detectors.
- Integrates into standard 4-20mA DCS, PLC, and ESD safety control networks.
Certifications & Standards
- ATEX Zone 1 and Zone 2 hazardous location compliance.
- IECEx international safety standard certification for hazardous explosive atmospheres.
- SIL2 rating suitable for safety instrumented industrial system designs.
Package Contents & Warranty
- 1 x Honeywell XNX-AMAI-RNIF1 Universal Transmitter Unit
- 1 x Factory Calibration Certificate and Quality Test Record
- 1 x Quick Start Installation and Operating Manual
- 12-Month Comprehensive Warranty Clause Included
Shipping & Logistics
- Fast Dispatch: Orders process and ship within 24 to 48 hours.
- Global Express Carriers: Shipped globally via FedEx, UPS, or DHL express services.
- Protective Packaging: Shipped in high-density anti-vibration industrial packaging.
Typical Application Scenarios
- Onshore and offshore oil drilling rigs and production platforms.
- Refining units, chemical processing plants, and fuel storage facilities.
- Gas turbine enclosure monitoring and pipeline compressor stations.
Diagnostic Capabilities
- Continuous monitoring of optical alignment and sensor window cleanliness.
- Automatic fault reporting for internal hardware failures or power drops.
- Backlit graphical LCD display showing real-time status and concentration levels.
Frequently Asked Questions (FAQ)
Q: Does the XNX-AMAI-RNIF1 require non-intrusive calibration in hazardous areas?
A: Yes. Technicians can calibrate the unit using magnetic switches through the glass front cover without opening the enclosure.
Q: What is the main advantage of the optical IR sensor over catalytic bead sensors?
A: The optical IR sensor operates without oxygen and resists poisoning from silicones or hydrogen sulfide gases.
Q: How does the relay option (R) enhance local plant safety?
A: The relay module triggers local beacons or sirens instantly without waiting for DCS controller intervention.
Q: Can I interchange sensor personality cards inside the transmitter body?
A: Yes. The modular design accepts electrochemical, catalytic, or infrared sensor interface cards easily.

Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.



