Honeywell XNX-AMAI-NHIC1 IR CO2 Universal Gas Detector
Manufacturer: Honeywell
Product No.: XNX-AMAI-NHIC1
Condition: En stock
Product Type: Universal Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 4400g
Shipping port: Xiamen
Warranty: 12 months
Tiempo estimado de entrega: 12-26 días (Internacional), 3-6 días (Estados Unidos).
Devolución dentro de los 30 días siguientes a la compra. Los aranceles e impuestos no son reembolsables.
Pago Seguro Garantizado
Product Overview
The Honeywell XNX Universal Transmitter functions as a flexible gas detection platform. The specific unit model XNX-AMAI-NHIC1 integrates advanced infrared carbon dioxide sensing technology. Plant operators deploy this device to monitor hazardous gas leaks reliably in heavy industrial environments. Engineers design this transmitter for seamless integration into existing plant safety infrastructures.
MECE Technical Specifications
| Parameter Category | Specification Details |
|---|---|
| Brand & Model | Brand: Honeywell | Series: XNX Universal Transmitter | Model: XNX-AMAI-NHIC1 |
| Measurement Range | Infrared Carbon Dioxide: 0 to 5% Vol. |
| Response & Sensitivity | Fast optical response time ensures immediate gas detection with high analytical sensitivity. |
| Linearity & Resolution | Maintains strict linear output across the full measurement scale with fine digital resolution. |
| Environmental Operating Limits | Operates reliably across harsh industrial temperature ranges and high humidity conditions. |
| Interference Resistance | Features advanced optical filtering to eliminate false alarms from background moisture or dust. |
| Electrical & Communication | Local HART communication protocol supports remote configuration and diagnostic monitoring. |
| Enclosure & Material | Durable painted aluminium housing ensures robust physical protection in hazardous zones. |
Installation Guide
- Mount the XNX-AMAI-NHIC1 securely onto rigid vertical walls or structural pipes.
- Ensure sufficient clearance around the sensor head for unrestricted gas diffusion.
- Route shielded cables through the M25 cable entry port to prevent signal noise.
- Verify ground continuity before applying power to the terminal blocks.
Commissioning and Maintenance Convenience
- Power the transmitter using standard DC industrial power supplies.
- Use the local HART handheld communicator to configure output parameters instantly.
- Perform optical optics checks easily without opening the flameproof housing.
- Replace internal sensor modules quickly during scheduled plant maintenance cycles.
Compatibility and System Integration
The XNX-AMAI-NHIC1 connects directly with Honeywell controllers and standard DCS systems. The unit supports generic 4-20mA current loops and digital HART data protocols. Plant engineers integrate this transmitter alongside Searchline Excel and Searchpoint Optima detectors seamlessly.
Compliance and Safety Certifications
- ATEX certified for explosive atmosphere deployment.
- IEC standards compliant for international industrial safety.
- M25 threaded entry meets stringent mechanical protection requirements.
Logistics, Packaging, and Warranty Terms
- Secure industrial packaging protects the instrument against transit impacts.
- Fast dispatch occurs within 24 to 48 hours after order confirmation.
- Global delivery relies on trusted carriers including FedEx, UPS, and DHL.
- A standard 12-month quality warranty covers all manufacturing defects.
Typical Application Scenarios
- Upstream oil and gas extraction platforms monitor carbon dioxide accumulation continuously.
- Chemical processing plants protect workers near reaction vessels and gas storage tanks.
- Power generation facilities track flue gas emissions and confined space hazards.
- Water treatment plants secure enclosed carbon dioxide dosing rooms effectively.
Advanced Diagnostic Capabilities
The XNX-AMAI-NHIC1 monitors internal optical lens contamination in real time. The transmitter issues early warning flags before signal degradation impacts plant safety. Diagnostic logs track historical fault codes to simplify troubleshooting for instrumentation technicians.
Global PLC Spare HUB's Insight
Instrumentation engineers often face signal drift issues when deploying electrochemical sensors in high-humidity offshore platforms. Field experience shows that upgrading to infrared units like the XNX-AMAI-NHIC1 eliminates frequent calibration cycles. For example, a North Sea gas facility reduced annual maintenance downtime by 40 percent after replacing older sensor technologies with this robust Honeywell platform.
Model Selection Guide & Technical Comparison
Choosing the correct gas detector variant depends on your specific communication and sensor requirements. Review the technical comparison below to select the optimal model for your facility:
| Model Number | Communication Protocol | Sensor Type & Range | Technical Recommendation |
|---|---|---|---|
| XNX-AMAI-NHIC1 (Current Model) | Local HART Enabled | IR Carbon Dioxide (0-5% Vol) | Recommended for plants requiring local digital diagnostics and infrared CO2 monitoring. |
| XNX-AMAI-NNIC1 | Standard 4-20mA (No HART) | IR Carbon Dioxide (0-5% Vol) | Ideal for legacy control systems that do not utilize HART protocol networks. |
Frequently Asked Questions
Question: How often must technicians calibrate the XNX-AMAI-NHIC1 transmitter?
Answer: Technicians should verify calibration every six months using certified test gases to ensure optimal measurement accuracy.
Question: Can plant personnel clean the optical lens assembly in the field?
Answer: Yes, maintenance staff can wipe the optical windows clean when the diagnostic LED indicates surface dust accumulation.
Question: What cable type should engineers use during electrical installation?
Answer: Engineers must use shielded twisted-pair instrumentation cables to prevent electromagnetic interference in industrial plants.

Tags
P: ¿Son estas piezas 100% originales y nuevas?
R: Sí. Cada componente está garantizado como 100% original, completamente nuevo y sellado de fábrica. También ofrecemos una garantía integral de 12 meses para su tranquilidad.
P: ¿Qué tan rápido es el envío a mi país?
R: Para artículos en stock, ofrecemos envío el mismo día. El envío exprés internacional (DHL/FedEx/UPS) generalmente entrega en un plazo de 3 a 5 días hábiles en todo el mundo.
P: ¿Puedo obtener una cotización formal con los costos de envío?
R: Absolutamente. Nuestro equipo de ventas está listo para proporcionar una factura proforma (PI) detallada que incluya las tarifas de envío más competitivas para su ubicación.
P: ¿Ofrecen descuentos por pedidos al por mayor?
R: Ofrecemos precios basados en el volumen para proyectos grandes o pedidos de varios artículos. Póngase en contacto con nosotros para obtener nuestra Garantía de Mejor Precio.
Garantía Integral de 12 Meses
Cada pieza suministrada por Global PLC Spare Hub está cubierta por una garantía de 12 meses a partir de la fecha de la factura.
- Cobertura: Defectos funcionales y fallos de hardware bajo condiciones normales de funcionamiento.
- Compromiso: Ofrecemos reparación, reemplazo o un reembolso completo inmediato para cualquier componente defectuoso verificado, para minimizar su tiempo de ininactividad operativa.
Política de Devoluciones y Cambios
Ofrecemos una política de devolución de 30 días para asegurar que reciba la pieza exacta que su sistema requiere.
- Elegibilidad: Se aceptan devoluciones de artículos sin instalar en su embalaje original sellado de fábrica.
- Proceso de RMA: Póngase en contacto con nuestro equipo de soporte para obtener un número de Autorización de Devolución de Mercancía (RMA) antes del envío.
- Procesamiento Rápido: Los reembolsos o cambios se procesan dentro de 3 a 5 días hábiles después de que el artículo devuelto pasa nuestra inspección técnica.
¿Necesita Asistencia Técnica? ¿No está seguro de si esta pieza es compatible con su sistema? [Consulte a nuestros Ingenieros] antes de comprar para asegurar una compatibilidad del 100%.