الرئيسية XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX
XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX

XNX-AMSV-RNNNN Honeywell XNX Gas Transmitter 316SS Relay ATEX

  • Manufacturer: Honeywell

  • Product No.: XNX-AMSV-RNNNN

  • Condition: متوفر بالمخزون

  • Product Type: Universal Gas Transmitter

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
اطلب عرض سعر

تقدير أوقات التسليم: 12-26 يومًا (دوليًا)، 3-6 أيام (الولايات المتحدة).

يجب الإرجاع خلال 30 يومًا من الشراء. الرسوم والضرائب غير قابلة للاسترداد.

دفع آمن ومضمون

Generic
Generic
Generic
Generic

Overview

The XNX-AMSV-RNNNN Honeywell Universal Transmitter delivers robust, multi-gas sensing coverage engineered specifically for high-temperature and combustible gas detection environments. Built with a painted 316 stainless steel housing, this unit operates as a high-reliability interface for millivolt (mV) sensor inputs, including Sensepoint HT, Model 705, and Multi-Purpose Detector (MPD) assemblies. It integrates directly into safety shutdown loops via dual-output architectures: standard 4-20mA with HART protocol and three fully configurable internal SPCO relays.

Product Architecture & Configuration Breakdown

  • Honeywell XNX Series Platform
    • Approval Type [A]: ATEX / IECEx Hazardous Area Certified
    • Enclosure Entry [M]: 5 x M25 Threaded Entries
    • Housing Material [S]: Marine-grade Painted 316 Stainless Steel
    • Sensor Personality [V]: mV Input Interface (Sensepoint HT, Model 705, MPD)
    • Hardware Option [R]: 3 x Form "C" SPCO Alarm/Fault Relays Installed
    • Local Interface [N]: No Local External HART Port Installed
    • Sensor Range [NNN]: Base Transmitter Assembly (Sensor Sold Separately)

Engineering Specifications Matrix

Technical Parameter Field Specification Standard
Brand & Series Honeywell XNX Universal Transmitter
Full Part Number XNX-AMSV-RNNNN
Input Signal Type Millivolt (mV) Bridge Signal for Catalytic Bead and IR Sensors
Primary Output Signal 4-20mA Analog Signal with Integrated HART Protocol
Secondary Relay Output 3 Form "C" SPCO Contacts (2 Alarm, 1 Fault) @ 250VAC 5A / 24VDC 5A
Measurement Range 0–100% LEL / Target Sensor Specific
Signal Resolution 0.1% LEL Digital Communication Output
Linearity & Response Linear 4-20mA Output; T90 Response Time Sensor Dependent
Noise Immunity (EMC) EN 50270 Industrial Electromagnetic Compatibility Standard
Ingress Protection IP66 Enclosure Rating (NEMA 4X equivalent)
Operating Temperature -40°C to +65°C (-40°F to +149°F) Base Transmitter Rating
Operating Humidity 0 to 99% RH non-condensing
Operating Pressure 80 kPa to 120 kPa Absolute Pressure
Physical Unit Weight 6.8 Kg (Solid Stainless Steel Housing)

Compatible Hardware & Field Application Scenarios

  • Compatible Sensor Hardware:
    • Sensepoint High Temperature (HT) Combustible Gas Sensors
    • Model 705 High-Temperature Catalytic Bead Detectors
    • MPD Series Catalytic and Infrared Millivolt Cartridges
  • Target Industrial Applications:
    • Turbine enclosures, exhaust ducting, and high-ambient heat zones up to 150°C (via remote HT sensors).
    • Offshore FPSOs, drilling rigs, and coastal LNG regasification terminals requiring 316SS corrosion resistance.
    • Standalone safety isolation skid systems leveraging direct relay contact interlocks without external PLCs.

Diagnostic & Predictive Monitoring Capabilities

The internal diagnostic engine on the XNX-AMSV-RNNNN Honeywell transmitter actively continuously samples internal supply voltage, memory checksums, sensor loop continuity, and bridge zero stability. In the event of a damaged sensor filament, low voltage condition, or signal drift, the unit instantly forces the 4-20mA signal into a dedicated fault state (≤2.0mA) and drops the dedicated internal Fault Relay contact, allowing control room operators to intercept failures before process safety trip thresholds are breached.

Model Selection Comparison & Engineering Recommendation

Selecting the correct model configuration is critical for long-term field stability. Below is a side-by-side comparison between the XNX-AMSV-RNNNN and the alternative XNX-AMAV-NHNNN transmitter configuration:

Selection Feature XNX-AMSV-RNNNN XNX-AMAV-NHNNN
Enclosure Material Painted 316 Stainless Steel (6.8 kg) Painted LM25 Marine-Grade Aluminum (2.8 kg)
Relay Capability 3 x Mechanical SPCO Relays Included No Relays Installed (Loop-Powered Only)
Local Interface Standard Housing (No External HART Port) Integrated Local External HART Port Included
Cable Entry Access 5 x M25 Threaded Entries 5 x M25 Threaded Entries

Engineering Advice: Choose the XNX-AMSV-RNNNN for severe corrosive atmospheres (such as marine spray zones or acid vapor exposure) or when local electromechanical interlocks (horns, beacons, automatic valve closures) must be driven directly by the transmitter. Conversely, select the XNX-AMAV-NHNNN if weight reduction is crucial, local hand-held HART technician access is preferred on the unit exterior, and all alarm processing is handled entirely by a central DCS/PLC system.

Global PLC Spare HUB's Insight

During a retrofit commissioning project on a gas turbine enclosure, our automation team encountered persistent signal trip faults on a competitor's transmitter due to high ambient heat radiation breakdown. Replacing the standard assemblies with the XNX-AMSV-RNNNN Honeywell combined with a remote-mounted Sensepoint HT sensor resolved the false tripping completely. The heavy 316 stainless steel casing acts as an excellent thermal buffer, and utilizing the 5th M25 cable gland for auxiliary relay wiring simplified the local shutdown wiring loop significantly without needing an extra junction box.

Warranty, Logistics & Ordering Information

  • Product Condition: 100% Brand New and Original Factory Supply
  • Warranty Coverage: Comprehensive 12-Month Quality Guarantee from dispatch date
  • Order Processing Time: Ships within 24 to 48 hours post-payment verification
  • Express Global Logistics: Direct fast shipping via FedEx, UPS, and DHL Express networks

Engineering Selection & Application FAQ

What is the primary advantage of choosing an 'mV' personality transmitter over an Optima interface model?

The 'V' (mV) personality is specifically tailored to process analog bridge resistance signals from high-temperature catalytic beads and MPD sensors, allowing you to monitor harsh areas (up to 150°C) where standard electronic optical transmitters cannot physically survive.

Does this unit include the local external HART socket on the bottom of the housing?

No. The model code designates 'N' under Local HART, meaning it does not feature the external plug-in port. HART protocol remains fully accessible internally across the main 4-20mA field wiring terminals or handheld device interface clips.

Can I use the internal relay contacts to trigger a local beacon and horn directly?

Yes. The 'R' option provides three SPCO contacts rated for 250VAC 5A / 24VDC 5A, allowing direct switching of power to local alarm horns or strobe lights without requiring external interposing relays.

What is the purpose of having 5 x M25 cable entry ports on this enclosure?

Having 5 ports accommodates incoming main power, analog 4-20mA loop signaling, relay output wiring multi-core cables, and direct connections to remote sensors without needing separate external explosion-proof junction boxes.

How do I perform routine zero and span gas calibrations on this transmitter model?

Use the magnetic wand tool on the front glass display glass face to navigate the internal LCD menu. This allows field technicians to execute non-intrusive zero and span adjustments in hazardous zones without opening the flameproof 316SS enclosure.

س: هل هذه الأجزاء أصلية وجديدة 100%؟

ج: نعم. نضمن أن كل مكون هو أصلي 100%، وجديد تمامًا، ومغلف من المصنع. كما نقدم ضمانًا شاملاً لمدة 12 شهرًا لراحتك.

س: ما مدى سرعة الشحن إلى بلدي؟

ج: بالنسبة للعناصر المتوفرة في المخزون، نقدم إرسالاً في نفس اليوم. وعادةً ما يتم التسليم عبر الشحن السريع الدولي (DHL/FedEx/UPS) في غضون 3-5 أيام عمل في جميع أنحاء العالم.

س: هل يمكنني الحصول على عرض أسعار رسمي يشمل تكاليف الشحن؟

ج: بالتأكيد. فريق المبيعات لدينا مستعد لتقديم فاتورة مبدئية (PI) مفصلة تتضمن أسعار الشحن الأكثر تنافسية لموقعك.

س: هل تقدمون خصومات للطلبات الكبيرة؟

ج: نقدم أسعارًا تعتمد على الحجم للمشاريع الكبيرة أو طلبات العناصر المتعددة. يرجى الاتصال بنا للحصول على ضمان أفضل الأسعار لدينا.




ضمان شامل لمدة 12 شهرًا

كل جزء توفره Global PLC Spare Hub مشمول بـ ضمان لمدة 12 شهرًا من تاريخ الفاتورة.

  • التغطية: عيوب وظيفية وأعطال في الأجهزة في ظل ظروف التشغيل العادية.
  • التزامنا: نقدم إصلاحًا فوريًا أو استبدالًا أو استردادًا كاملاً لأي مكونات معيبة تم التحقق منها لتقليل وقت التوقف التشغيلي لديك.

سياسة الإرجاع والاستبدال

نقدم سياسة إرجاع لمدة 30 يومًا لضمان حصولك على الجزء الدقيق الذي يتطلبه نظامك.

  • الأهلية: تُقبل المرتجعات للعناصر غير المركبة في تغليفها الأصلي والمحكم الإغلاق من المصنع.
  • عملية RMA: يرجى الاتصال بفريق الدعم لدينا للحصول على رقم ترخيص إرجاع البضائع (RMA) قبل الشحن.
  • معالجة سريعة: تتم معالجة المبالغ المستردة أو الاستبدالات في غضون 3-5 أيام عمل بعد أن يجتاز العنصر المرتجع فحصنا الفني.

هل تحتاج إلى مساعدة فنية؟لست متأكدًا مما إذا كان هذا الجزء متوافقًا مع نظامك؟ [استشر مهندسينا] قبل الشراء لضمان التوافق بنسبة 100%.




مشاركة المدونة