Product Introduction | MKS 626D Absolute Pressure Measurement
The MKS Instruments 626D01TDE is an unheated absolute capacitance manometer from the MKS 626D Baratron® series. It measures absolute pressure through a variable capacitance sensing principle.
Its all-metal welded construction uses corrosion-resistant nickel alloys. The sensing element provides direct pressure measurement with minimal dependence on gas composition. This characteristic makes it suitable for precise vacuum process control.
This configuration features a 1 Torr full-scale range, an NW16 / KF16 vacuum connection, and a 15-pin D-sub electrical connector. It provides a linear 0–10 VDC analog output for compatible pressure monitoring systems.
The unheated design operates at ambient temperatures from 0°C to 50°C. It supports vacuum measurement applications that require stable pressure feedback without a heated sensor assembly.
01. Model Identification & Configuration Breakdown
Complete Part Number: 626D01TDE
| Model Segment | Configuration | Description |
| 626D | Product Series | Unheated absolute Baratron capacitance manometer |
| 01T | Range Code | 1 Torr full-scale measurement range |
| D | Fitting Code | NW16 / KF16 vacuum flange |
| E | Electrical / Accuracy Code | 15-pin D-sub connector and 0.25% of reading accuracy |
Configuration Logic:
- 626D: Defines the unheated absolute pressure measurement platform.
- 01T: Defines the 1 Torr full-scale pressure range.
- D: Specifies the NW16 / KF16 mechanical connection.
- E: Identifies the electrical connector and accuracy configuration.
This configuration breakdown helps engineers identify the required pressure range, vacuum interface, and electrical connection before ordering.
02. Technical Specifications | Measurement & Performance
| Manufacturer | MKS Instruments |
| Model | 626D01TDE |
| Product Series | 626D Baratron® Series |
| Product Type | Unheated Absolute Capacitance Manometer |
| Measurement Principle | Variable capacitance measurement |
| Pressure Reference | Absolute pressure |
| Full-Scale Range | 1 Torr |
| Measurement Accuracy | ±0.25% of Reading |
| Resolution | 0.001% of Full Scale |
| Zero Temperature Coefficient | 0.04% of Reading/°C |
| Measurement-Side Volume | 6.3 cm³ |
| Operating Temperature | 0°C to +50°C |
| Overpressure Limit | 45 psia (310 kPa) |
Measurement principle: The instrument detects pressure-induced diaphragm movement through changes in electrical capacitance. It converts this change into a proportional analog signal.
Unlike thermal conductivity gauges, capacitance manometers measure pressure through mechanical diaphragm response. Their readings do not depend on gas species in the same way as gas-dependent measurement technologies.
03. Electrical Interface & Signal Transmission
| Electrical Connector | 15-pin D-subminiature |
| Supply Voltage | ±15 VDC (±5%) |
| Input Current | 35 mA |
| Analog Output | 0–10 VDC |
| Output Load | Greater than 10 kΩ |
| Output Characteristics | Linear analog pressure signal |
The 0–10 VDC output supports integration with compatible analog input modules and pressure control equipment.
Engineers should verify the connector pin assignment and power supply requirements before wiring. The receiving input must also provide an appropriate load impedance.
04. Wetted Materials & Mechanical Construction
The 626D01TDE uses a corrosion-resistant, all-metal welded sensing structure. Its pressure-exposed components use Inconel® and Incoloy® nickel alloys.
- Wetted Materials: Inconel® and Incoloy® nickel alloys.
- Construction: All-metal welded design.
- Vacuum Connection: NW16 / KF16 flange.
- Measurement-Side Volume: 6.3 cm³.
- Pressure Rating: 45 psia overpressure limit.
- Sensor Heating: Unheated configuration.
The welded metal structure avoids relying on conventional elastomeric sensing diaphragms. Material selection supports compatibility with demanding vacuum process environments.
05. Installation & Vacuum System Integration
Mechanical Installation
- Verify the 1 Torr measurement range against the process requirements.
- Confirm the vacuum port matches the NW16 / KF16 connection.
- Inspect flange sealing surfaces before assembly.
- Use compatible vacuum sealing components.
- Mount the gauge in a suitable orientation according to manufacturer instructions.
- Avoid excessive mechanical stress on the flange and instrument body.
- Keep the pressure port clean during installation.
Electrical Installation
- Prepare a compatible ±15 VDC power supply.
- Check the 15-pin D-sub connector and pin configuration.
- Connect the analog output to a suitable voltage input.
- Verify that the receiving load exceeds 10 kΩ.
- Check power polarity and electrical grounding.
- Confirm the output signal before starting process operation.
06. Commissioning, Calibration & Maintenance
Commissioning Procedure
- Allow the instrument to stabilize within its specified ambient temperature range.
- Verify the supply voltage and electrical connections.
- Check the zero-pressure output under the appropriate reference conditions.
- Compare readings against a suitable calibrated pressure reference.
- Verify the analog output across the intended measurement range.
- Check for pressure leakage around the vacuum connection.
Maintenance Recommendations
- Inspect vacuum flange sealing surfaces during scheduled maintenance.
- Monitor zero-point stability over time.
- Check analog signal consistency against reference instruments.
- Keep the pressure port free from process deposits.
- Review calibration requirements according to process accuracy needs.
- Investigate abnormal zero shifts before adjusting the control system.
Engineering Note: Avoid applying pressure beyond the specified 45 psia overpressure limit. Follow the manufacturer's calibration and service procedures.
07. System Compatibility & Application Selection
The MKS 626D01TDE is designed for absolute pressure measurement in compatible vacuum systems. Its analog output supports connection to suitable process monitoring and control equipment.
| Integration Item | Selection Requirement |
| Vacuum Interface | NW16 / KF16 compatible port |
| Power Supply | ±15 VDC, ±5% |
| Signal Input | 0–10 VDC analog input |
| Input Impedance | Greater than 10 kΩ |
| Pressure Range | 1 Torr full scale |
| Temperature | 0°C to +50°C ambient |
| Connector | 15-pin D-subminiature |
Typical integration environments include:
- Semiconductor Manufacturing: Vacuum process pressure monitoring.
- Thin-Film Deposition: Pressure feedback for vacuum chambers.
- Vacuum Coating: Absolute pressure measurement during coating processes.
- Industrial Vacuum Systems: Pressure monitoring and process regulation.
- Research Equipment: Vacuum measurement in laboratory instruments.
- Process Control Systems: Analog pressure feedback for automated equipment.
08. Compliance & Product Standards
| CE Compliance | CE compliant |
| Measurement Type | Absolute pressure |
| Construction | All-metal welded sensing structure |
| Electrical Output | 0–10 VDC |
Confirm the applicable declaration of conformity and installation requirements for the exact instrument configuration before use.
09. Packaging, Warranty & International Shipping
Standard Package Contents:
- 1 × MKS Instruments 626D01TDE Capacitance Manometer.
- Product identification and configuration information, where supplied.
- Protective transportation packaging.
Product Condition: New & Original in Factory Packing.
Warranty: Factory Warranty: 12 Months.
Shipping Methods: FedEx, UPS, and DHL international express delivery.
Order Assistance: Contact our sales team for price quotations, stock confirmation, and delivery schedules.
Frequently Asked Questions
1. What is the difference between absolute pressure and gauge pressure?
Absolute pressure uses a perfect vacuum as its reference point. Gauge pressure uses local atmospheric pressure as its reference. The 626D01TDE measures absolute pressure, so atmospheric pressure changes do not redefine its measurement zero.
2. Can the 626D01TDE measure different process gases without changing its calibration factor?
Its capacitance measurement principle does not rely on gas thermal conductivity. Therefore, gas composition does not create the same measurement correction requirements found in thermal conductivity gauges. However, process compatibility and possible contamination still require evaluation.
3. Why is an unheated capacitance manometer useful in vacuum equipment?
An unheated design operates without a dedicated heater circuit. It simplifies power requirements and avoids intentional heating of the sensing assembly. This configuration is useful when the process allows ambient-temperature operation.
4. How should engineers investigate an unstable pressure reading after chamber installation?
First, inspect the vacuum flange and sealing surfaces for leakage. Then check the power supply, signal cable, grounding, and analog input configuration. If the installation passes these checks, compare the instrument against a calibrated reference. Also consider temperature changes and process contamination.
5. What should buyers verify when replacing an existing MKS Baratron gauge?
Compare the full-scale range, pressure reference, flange type, connector pinout, supply voltage, and analog output. Also check the required accuracy and process temperature. A similar-looking 626D model may have a different range or connection configuration. Request a complete model-number comparison before ordering.

Tags
س: هل هذه الأجزاء أصلية وجديدة 100%؟
ج: نعم. نضمن أن كل مكون هو أصلي 100%، وجديد تمامًا، ومغلف من المصنع. كما نقدم ضمانًا شاملاً لمدة 12 شهرًا لراحتك.
س: ما مدى سرعة الشحن إلى بلدي؟
ج: بالنسبة للعناصر المتوفرة في المخزون، نقدم إرسالاً في نفس اليوم. وعادةً ما يتم التسليم عبر الشحن السريع الدولي (DHL/FedEx/UPS) في غضون 3-5 أيام عمل في جميع أنحاء العالم.
س: هل يمكنني الحصول على عرض أسعار رسمي يشمل تكاليف الشحن؟
ج: بالتأكيد. فريق المبيعات لدينا مستعد لتقديم فاتورة مبدئية (PI) مفصلة تتضمن أسعار الشحن الأكثر تنافسية لموقعك.
س: هل تقدمون خصومات للطلبات الكبيرة؟
ج: نقدم أسعارًا تعتمد على الحجم للمشاريع الكبيرة أو طلبات العناصر المتعددة. يرجى الاتصال بنا للحصول على ضمان أفضل الأسعار لدينا.
ضمان شامل لمدة 12 شهرًا
كل جزء توفره Global PLC Spare Hub مشمول بـ ضمان لمدة 12 شهرًا من تاريخ الفاتورة.
- التغطية: عيوب وظيفية وأعطال في الأجهزة في ظل ظروف التشغيل العادية.
- التزامنا: نقدم إصلاحًا فوريًا أو استبدالًا أو استردادًا كاملاً لأي مكونات معيبة تم التحقق منها لتقليل وقت التوقف التشغيلي لديك.
سياسة الإرجاع والاستبدال
نقدم سياسة إرجاع لمدة 30 يومًا لضمان حصولك على الجزء الدقيق الذي يتطلبه نظامك.
- الأهلية: تُقبل المرتجعات للعناصر غير المركبة في تغليفها الأصلي والمحكم الإغلاق من المصنع.
- عملية RMA: يرجى الاتصال بفريق الدعم لدينا للحصول على رقم ترخيص إرجاع البضائع (RMA) قبل الشحن.
- معالجة سريعة: تتم معالجة المبالغ المستردة أو الاستبدالات في غضون 3-5 أيام عمل بعد أن يجتاز العنصر المرتجع فحصنا الفني.
هل تحتاج إلى مساعدة فنية؟لست متأكدًا مما إذا كان هذا الجزء متوافقًا مع نظامك؟ [استشر مهندسينا] قبل الشراء لضمان التوافق بنسبة 100%.