XNX-AMAI-MNIV1 Honeywell Gas Transmitter Series XNX Universal | Get Quote
Manufacturer: Honeywell
Product No.: XNX-AMAI-MNIV1
Condition: In stock
Product Type: Universal Gas Transmitter
Product Origin: USA
Payment: T/T, Western Union
Weight: 4400g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Global PLC Spare HUB's Insight
Harsh hazardous atmospheres demand continuous, reliable gas detection infrastructure capable of withstanding extreme environmental stress. Based on field telemetry insights at Global PLC Spare HUB, deploying the Honeywell XNX-AMAI-MNIV1 from the XNX Universal Transmitter lineup ensures dependable infrared methane monitoring across heavy industrial plants. During a recent offshore platform safety audit, integrating this rugged universal transmitter with built-in Modbus communication successfully eradicated false low-level telemetry dropouts and stabilized real-time hydrocarbon tracking across corrosive marine zones.
Technical Architecture & Specifications Matrix
| Manufacturer Brand | Honeywell |
| Model Part Number | XNX-AMAI-MNIV1 |
| Product Series | XNX Universal Transmitter |
| Sensor and Detection Range | Infrared 0-100% LEL (or 0-5% Vol.) Methane |
| Enclosure Protection & Weight | Heavy-duty industrial build, 4.4 kg (9.7 lbs) net mass |
Configuration Breakdown & Suffix Analysis
- Base Model: XNX Universal Gas Detector Platform
- Approval Code (A): ATEX / IEC Hazardous Area Certification
- Cable Entry Type (M): M25 Threaded Conduit Entries
- Housing Material (A): Robust Painted Aluminium Enclosure
- Personality Card (I): Infrared Interface for Searchline Excel, Searchpoint Optima, and Generic 4-20mA inputs
- Communication Option (M): Integrated Modbus Network Interface
- Local HART (N): Without Local HART Communication Protocol
- Sensor & Range (IV1): Factory-configured Methane IR cell (0 to 100% LEL / 0 to 5% Vol)
Engineering Installation Guidelines
- Mount the XNX-AMAI-MNIV1 securely onto flat structural walls or rigid pipe racks using approved mounting brackets.
- Ensure M25 cable entries are fitted with certified flameproof glands to preserve enclosure integrity in explosion-risk zones.
- Connect the Modbus communication wiring correctly while maintaining proper shielding termination to prevent ground loops.
- Verify that the 24V DC operating voltage is stable prior to initializing sensor calibration routines.
Built-in Diagnostics & Operational Health Checks
- Features an onboard multi-character local display for instant readout of gas concentration, fault codes, and calibration states.
- Transmits real-time diagnostic flags via Modbus architecture to central control room SCADA systems for proactive maintenance.
- Performs continuous optical path monitoring to detect lens contamination or signal degradation before system faults occur.
Target Equipment & Industrial Application Sectors
- Upstream oil and gas extraction platforms and downstream petrochemical refining terminals.
- Natural gas compressor stations and pipeline distribution metering skids.
- Combustible gas storage warehouses and heavy chemical processing facilities.
- Wastewater treatment anaerobic digestion tanks and biogas recovery plants.
Commercial Logistics & Quality Guarantee
- Express Global Fulfillment: Fast and reliable dispatch via FedEx, UPS, and DHL.
- Processing Turnaround: Stocked inventory packed and shipped within 24 to 48 hours.
- Contractual Protection: Backed by a comprehensive 12-month quality warranty from date of purchase.
Frequently Asked Questions
Q: What specific sensor technology does the XNX-AMAI-MNIV1 utilize for gas detection?
A: It uses an advanced infrared (IR) optical sensor specifically calibrated for detecting methane concentrations from 0 to 100% LEL or 0 to 5% Volume.
Q: How does the Modbus option enhance integration within a larger control system?
A: The integrated Modbus communication card allows direct digital data streaming of gas readings, status warnings, and diagnostic parameters to the PLC or DCS without requiring separate analog conversion wiring.
Q: What maintenance steps should I take if the optical path reports a contamination warning?
A: Safely access the detector housing, remove any accumulated dust, moisture, or chemical residue from the glass optics using a clean lint-free cloth, and re-check optical signal strength.
Q: Can this unit be deployed safely in explosive gas atmospheres?
A: Yes, it carries ATEX/IEC hazardous area approvals and features an explosion-proof aluminium housing designed for dangerous industrial environments.
Q: What factors should guide my selection when ordering replacement gas transmitters?
A: Always verify your target gas type, measuring scale, required hazardous area certification code, thread entry size (such as M25), and desired communication protocol before finalizing your purchase.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.