SPXCDULNRXM Honeywell Sensepoint XCD Flame Detector Safety Sensor
Manufacturer: Honeywell
Product No.: SPXCDULNRXM
Condition: In stock
Product Type: Flame Detector
Product Origin: USA
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview
The SPXCDULNRXM is an engineered industrial safety instrument part of the Honeywell Sensepoint XCD family, though configured specifically around advanced gas and flame detection parameters. Featuring a rugged red housing rated to IP65, this unit provides dual UV/IR sensing technology, Modbus data communication, and robust operation across harsh environments ranging from -40°C to +70°C.
Technical Parameters & Architecture Breakdown
| System Parameter | Engineering Specification |
|---|---|
| Brand / Manufacturer | Honeywell |
| Series & Device Type | Sensepoint XCD / Flame & Gas Detector |
| Model / Part Number | SPXCDULNRXM |
| Operating Voltage | 12–24 VDC nominal (10–28 VDC operating range) |
| Current Draw & Output | 25 mA normal operating current; 4–20 mA stepped, sinking, non-isolated output |
| Sensing Technology | Ultraviolet/Infrared (UV/IR) dual-sensor setup |
| Detection Range & Vision | 80 ft (25 m) range with 90° minimum horizontal and vertical cone of vision |
| Relay Outputs | Alarm and Fault SPDT relays, rated 30 VDC at 2A (60W max) |
| Ingress & Environmental | IP65 dust/moisture protection; -40°C to +70°C thermal envelope |
Logistics, Fulfillment, and Warranty
- Express Freight Partners: Secure international shipping managed through FedEx, UPS, and DHL.
- Processing Speed: Verified order handling, custom industrial packing, and dispatch within 24 to 48 hours.
- Warranty Coverage: Backed comprehensively by a standard 12-month operational replacement warranty.
Target Equipment, Applications, and Diagnostics
- Industrial Applications: Petrochemical processing plants, offshore oil drilling platforms, fuel storage terminals, and compressor skids.
- Diagnostic Capabilities: Integrated alarm and fault SPDT relay contacts combined with Modbus communications enable continuous self-monitoring and real-time controller status reporting.
- Operational Edge: Dual UV/IR sensing prevents nuisance trips from solar radiation or background artificial lighting while maintaining an 80-foot detection perimeter.
Global PLC Spare HUB's Insight
When commissioning units like the SPXCDULNRXM in outdoor or extreme-weather process areas, field technicians must account for window contamination. Dust, salt spray, or heavy condensation on the UV/IR sensor lens will attenuate optical transmission and degrade the 90-degree cone of vision. Regular cleaning schedules and verification of the 4-20 mA sinking loop stability are vital to preventing unlatched fault states.
Frequently Asked Questions
Question: What specific communication protocol is integrated into the SPXCDULNRXM configuration?
Answer: This model comes equipped with native Modbus communications alongside standard 4-20 mA current outputs and SPDT alarm/fault relays.
Question: How does the dual UV/IR sensing technology on the SPXCDULNRXM minimize false alarms?
Answer: By requiring simultaneous detection of ultraviolet and infrared spectral signatures, the sensor filters out non-threatening flickering light sources like sunlight or hot exhaust pipes.
Question: What physical conduit entry size does the housing utilize for field cabling?
Answer: The unit incorporates a standard 3/4-inch NPT entry port to accommodate heavy-duty industrial armored cable glands or conduit fittings.
Question: Can the SPXCDULNRXM withstand sub-zero arctic startup environments?
Answer: Yes, it features an operating temperature rating down to -40°C, making it suitable for cold-weather outdoor installations.
Question: What selection guidance applies when matching the SPXCDULNRXM power supply requirements?
Answer: Ensure the external power source delivers a steady DC voltage within the 10 to 28 VDC range while budgeting for the baseline 25 mA operating current plus relay activation loads.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.