MTL5045 MTL 5000 Series Analog Signal Isolator Current Loop Interface
Manufacturer: MTL
Product No.: MTL5045
Condition: In stock
Product Type: Signal Conditioner
Product Origin: USA
Payment: T/T, Western Union
Weight: 220g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
MTL5045 | MTL 5000 Series 4–20 mA Hazardous-Area Signal Isolator
The MTL5045 transfers a 4–20 mA control signal from safe-area equipment to a load located in a hazardous area. Its single-channel design supports an output load of up to 800 Ω, delivering 16 V at 20 mA while keeping the input voltage drop below 4 V at 20 mA.
For control engineers, the key selection factors are loop compliance voltage, output load resistance, hazardous-area certification, and supply voltage. The MTL5045 also provides a green power LED, low signal ripple, and a specified transfer accuracy better than 20 µA at 20°C.
Signal Path at a Glance
| Signal-path stage | MTL5045 function | Commissioning check |
|---|---|---|
| Safe-area input | Accepts a 4–20 mA signal, with an under/over-range span of 0–24 mA | Confirm controller output type, polarity, and available compliance voltage. |
| Isolation and transfer | Transfers the current signal through the isolator interface | Check supply voltage, wiring, and channel condition. |
| Hazardous-area output | Drives a load up to 800 Ω, rated at 16 V at 20 mA | Calculate the total loop load and confirm the receiving device's requirements. |
| Power indication | Green LED indicates power | Use the LED as a supply-status clue, not proof of correct signal transfer. |
Electrical Specifications
| Parameter | Specification |
|---|---|
| Model | MTL5045 |
| Number of channels | One |
| Safe-area input signal | 4–20 mA |
| Input under/over-range | 0–24 mA |
| Hazardous-area output load | Maximum 800 Ω |
| Output drive capability | 16 V at 20 mA |
| Output resistance | Greater than 2 MΩ |
| Input voltage drop | Less than 4 V at 20 mA |
| Input/output circuit ripple | Less than 40 µA peak-to-peak |
| Transfer accuracy at 20°C | Better than 20 µA |
| Temperature drift | Less than 1 µA/°C |
| Response time | Settles within 10% of final value in 250 µs |
| Supply voltage | 20–35 V DC |
| Maximum current consumption | 50 mA at 24 V; 60 mA at 20 V; 40 mA at 35 V |
| Maximum internal power dissipation | 1.0 W at 24 V; 1.1 W at 35 V, with a 20 mA signal |
| Safety description | 28 V, 300 Ω, 93 mA; Um = 250 V RMS or DC |
| Power LED | Green |
Terminal Assignment and Wiring Reference
Use the terminal numbers below to verify the field wiring against the applicable MTL5045 installation drawing. Isolate the circuit and follow site safety procedures before changing connections.
| Terminal | Function | Connection purpose |
|---|---|---|
| 1 | Output −ve | Negative output connection to the hazardous-area load circuit |
| 2 | Output +ve | Positive output connection to the hazardous-area load circuit |
| 11 | Input −ve | Negative safe-area current input |
| 12 | Input +ve | Positive safe-area current input |
| 13 | Supply −ve | Negative DC supply |
| 14 | Supply +ve | Positive DC supply |
Wiring reminder: Do not interchange the input, output, and supply terminals. Confirm polarity and terminal numbering on the actual unit before energizing the circuit. The terminal table is a reference, not a substitute for the manufacturer's approved wiring diagram.
Load Selection: Check the 800 Ω Limit
The MTL5045 can drive a maximum load of 800 Ω at 20 mA, with a specified output capability of 16 V. The total load must include the receiving instrument and the resistance contributed by field wiring and other series components.
| Example load | Voltage required at 20 mA | Selection implication |
|---|---|---|
| 250 Ω | 5 V | Below the specified maximum load |
| 500 Ω | 10 V | Below the specified maximum load |
| 800 Ω | 16 V | At the stated maximum output load |
| Above 800 Ω | More than 16 V at 20 mA | Outside the stated load rating; reassess the circuit design |
Use Ohm's law to estimate the load voltage: V = I × R. At 20 mA, an 800 Ω load requires 16 V. Keep the total resistance within the specified limit and confirm that the receiving device can accept the resulting signal.
Where the MTL5045 Fits
- PLC or DCS analog output to a hazardous-area load: Transfers a safe-area 4–20 mA control signal to a suitable field load when the installation meets the required intrinsic-safety conditions.
- Control valves and field actuators: Potentially suitable for compatible current-driven devices whose required signal, load, and certification match the interface specification.
- Process-control skids: Provides a single-channel interface for analog control loops routed between safe and hazardous areas.
- Industrial signal-interface cabinets: Fits applications that require a defined 4–20 mA transfer path and a 20–35 V DC supply.
Confirm the field load type before installation. A 4–20 mA signal interface is not automatically compatible with every positioner, actuator, indicator, or transmitter. Verify whether the receiving device expects a current input, the required loop direction, and the applicable hazardous-area approval.
Hazardous-Area Suitability and Safety Parameters
The supplied specification identifies the load location as Zone 0, IIC, T4–T6 hazardous area when suitably certified, and Division 1, Group A hazardous location. The listed safety description is 28 V, 300 Ω, 93 mA, with Um = 250 V RMS or DC.
- Verify the exact MTL5045 certification and the approval applicable to the installation jurisdiction.
- Check the field device's entity parameters and the complete intrinsically safe loop design against the manufacturer's documentation.
- Confirm cable parameters, grounding requirements, and installation drawings before energizing the circuit.
- Do not assume that a generic model description alone establishes suitability for a particular gas group, temperature class, or Zone 0 installation.
Field Diagnostics: Symptoms, Causes and Checks
| Observed symptom | Possible cause | Recommended diagnostic action |
|---|---|---|
| No output current | Missing supply, incorrect terminal wiring, open loop, or input signal absent | Check the green power LED, verify supply voltage at terminals 13 and 14, then measure the input signal using an approved method. |
| Output remains below the commanded value | Excessive loop resistance, incorrect polarity, or receiving-device loading | Calculate total loop resistance and confirm that the load does not exceed 800 Ω at 20 mA. |
| Reading fluctuates | Unstable controller output, loose connections, electrical interference, or poor wiring practices | Compare the safe-area input with the hazardous-area output and inspect terminals, cable routing, and shielding according to the installation design. |
| Current is correct at the input but incorrect at the load | Output-side wiring fault, excessive load, or a damaged interface | Check the output loop independently and compare measurements with the receiving instrument's input requirements. |
| Signal error changes with ambient temperature | Temperature drift or a temperature-related fault elsewhere in the loop | Compare the observed change with the specified drift of less than 1 µA/°C and inspect the complete loop before attributing the fault to the isolator. |
| Power LED is on but the signal is wrong | Input, output, polarity, load, or receiving-device issue | Remember that the LED indicates power only. Verify input current, output current, wiring, and load resistance separately. |
Practical troubleshooting sequence: Verify the DC supply first, then measure the safe-area input, check the hazardous-area loop and total load, and finally confirm the receiving device's configuration. Follow hazardous-area procedures and use appropriately rated test equipment; never bypass required intrinsic-safety protection to troubleshoot a live circuit.
Global PLC Spare HUB's Insight
For the MTL5045, a common selection mistake is checking only the nominal 4–20 mA range without verifying the load and voltage budget. At 20 mA, an 800 Ω load requires 16 V, which matches the stated output capability. A higher resistance can prevent the output from reaching the commanded current.
- Validate the loop budget: Include the receiving device, cable resistance, and any other series elements when calculating total load.
- Separate supply checks from signal checks: A green LED confirms power indication, but does not prove correct current transfer.
- Use the terminal numbers carefully: Input, output, and supply connections have distinct terminal pairs. Verify polarity before energizing the unit.
- Confirm hazardous-area compatibility: Select the interface based on the complete loop approval and field-device requirements, not the area classification alone.
- Compare input and output measurements: This helps distinguish a controller-side issue from a load, wiring, or interface-side problem.
Global PLC Spare HUB can help customers review the part number, current-loop requirements, load resistance, and application details before ordering industrial automation interface components.
Warranty and Shipping
- Product condition: New, original item, subject to order confirmation and availability.
- Warranty: 12-month warranty against qualifying product defects, subject to applicable sales terms.
- Shipping methods: FedEx, UPS, and DHL, subject to destination and service availability.
- Order verification: Confirm the exact model, quantity, destination, and any required compliance documentation before dispatch.
Frequently Asked Questions
1. Can the MTL5045 drive a 4–20 mA load that requires more than 16 V at 20 mA?
The stated output capability is 16 V at 20 mA, corresponding to a maximum load resistance of 800 Ω. If the complete loop requires more voltage, the application falls outside the stated load capability. Recalculate the load and review the receiving device's input requirements before selecting an interface.
2. What is the practical difference between the 0–24 mA input range and the normal 4–20 mA signal?
The normal operating signal is 4–20 mA. The stated 0–24 mA range describes the specified under/over-range span, not a replacement for the normal control range. Confirm how the controller and receiving device interpret underrange and overrange values before using them for alarms or fault logic.
3. If the green LED is on, does that prove the hazardous-area output is healthy?
No. The green LED indicates power. It does not confirm that the input signal reaches the output correctly or that the load is within specification. Compare the input and output current, inspect terminal polarity, and verify the total loop resistance.
4. How should I choose this model for a control valve or positioner?
Start by confirming that the field device accepts a 4–20 mA current input and determine its required voltage and input resistance. Then check the total load against the 800 Ω limit, verify the required hazardous-area certification, and confirm whether the application needs this particular signal-transfer arrangement.
5. What should I provide when asking for a replacement or compatibility check?
Provide the full model number, controller or output-card model, receiving-device model, measured or specified loop resistance, supply voltage, hazardous-area classification, and wiring arrangement. These details help determine whether the interface fits the circuit and whether the required approvals and load limits are satisfied.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



