MTL4576-THC Eaton MTL 4500 Series | Dual-Channel Temperature Signal Converter
Manufacturer: MTL
Product No.: MTL4576-THC
Condition: In stock
Product Type: Thermocouple Isolator Module
Product Origin: EN
Payment: T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
MTL4576-THC | Thermocouple Signal Conversion and Isolation
The MTL4576-THC belongs to the MTL 4500 Intrinsically Safe Isolators family. It converts low-level thermocouple and millivolt signals into standard 4-20mA outputs.
Its two-channel architecture supports temperature measurement from hazardous-area installations. Each channel provides configurable thermocouple linearisation, temperature ranging, monitoring, and testing functions.
The module integrates cold-junction compensation into its hazardous-area connection arrangement. Users do not need to order a separate cold-junction compensation component. Configuration uses a PC running MTL PCS45 software and a PCL45USB interface.
01 | Signal Conversion Architecture
The MTL4576-THC handles the complete temperature signal conversion process between field sensors and safe-area equipment.
- Field Input: Accepts low-level thermocouple signals and millivolt inputs.
- Thermocouple Processing: Supports eight standard thermocouple types plus XK.
- Cold-Junction Compensation: Provides automatic or selectable compensation.
- Signal Linearisation: Applies software-selected linearisation for supported thermocouple types.
- Analog Conversion: Converts processed measurements into 4-20mA currents.
- Safe-Area Interface: Drives compatible control-system input circuits.
This architecture helps connect hazardous-area temperature sensors to PLC, DCS, and other compatible analog input systems.
02 | Engineering Specification
| Manufacturer / Brand | Eaton MTL |
| Model | MTL4576-THC |
| Product Series | MTL 4500 |
| Product Category | Intrinsically Safe Thermocouple Isolator |
| Channel Configuration | Two independent channels |
| Input Signal Types | J, K, T, E, R, S, B, N and XK; mV input |
| Thermocouple Standard | BS 60584 |
| Input Signal Range | -75 to +75mV |
| Input Signal Span | 3 to 150mV |
| Cold-Junction Compensation | Automatic or selectable |
| Cold-Junction Error | ≤ 1.0°C |
| Output Signal | 4-20mA nominal |
| Maximum Output Load | 300Ω |
| Common-Mode Rejection | 120dB at 240V, 50Hz or 60Hz |
| Series-Mode Rejection | 40dB at 50Hz or 60Hz |
| Input Calibration Accuracy | ±15µV or ±0.05% of input value, whichever is greater |
| Output Calibration Accuracy | ±16µA |
| Input Temperature Drift | ±0.003% of input value/°C, typical |
| Output Temperature Drift | ±0.6µA/°C, typical |
| Sensor Burnout Response | Upscale, downscale, or off |
| Maximum Lead Resistance | 300Ω with sensor-failure safety drive enabled; greater than 10kΩ with safety drive disabled |
| Response Time | Configurable; 500ms default |
| Power Supply | 60mA at 24V with 20mA signal |
| Power Dissipation | 1.4W at 24V with 20mA signal |
| Isolation | Functional channel-to-channel isolation and isolation between safe and hazardous-area circuits |
| LED Indicators | Green power/status, yellow channel status, red alarm |
| Hazardous-Area Application | Zone 0, IIC, T4–T6; Division 1, Group A |
| Maximum External Voltage | Um = 253V rms or DC |
| Configuration Software | MTL PCS45 |
| Configuration Interface | PCL45USB serial interface |
03 | Measurement Integrity and Interference Rejection
Low-level thermocouple signals require careful interference control. The MTL4576-THC provides defined rejection and calibration characteristics for industrial measurement applications.
Interference Rejection
- 120dB Common-Mode Rejection: Reduces common-mode interference at 240V and 50/60Hz.
- 40dB Series-Mode Rejection: Suppresses specified series-mode interference at 50/60Hz.
- Channel Isolation: Provides functional isolation between channels and circuit areas.
Calibration Performance
- Input accuracy: ±15µV or ±0.05% of input value, whichever is greater.
- Output accuracy: ±16µA.
- Cold-junction compensation error: Maximum 1.0°C.
- Input drift: Typically ±0.003% of input value per °C.
- Output drift: Typically ±0.6µA per °C.
These specifications help engineers evaluate signal integrity and measurement uncertainty. Actual loop performance also depends on sensor accuracy, wiring, installation conditions, and calibration.
04 | Cold-Junction Compensation and Sensor Configuration
Thermocouples generate millivolt signals based on temperature differences. Accurate conversion therefore requires appropriate cold-junction compensation.
The MTL4576-THC integrates this function into its hazardous-area connection arrangement. Engineers can select automatic or configurable compensation modes.
Supported thermocouple types include:
| Thermocouple Type | Engineering Application |
| J | General industrial temperature measurement |
| K | Wide-range industrial temperature monitoring |
| T | Low-temperature measurement applications |
| E | Temperature measurement requiring high thermoelectric output |
| R / S | High-temperature process measurement |
| B | High-temperature furnace applications |
| N | Industrial high-temperature measurement |
| XK | Supported special thermocouple input configuration |
Verify the thermocouple type and applicable sensor calibration standard before configuring each channel.
05 | Configuration and Commissioning Workflow
Configuration requires a personal computer with the appropriate MTL software and interface hardware.
- Prepare the Hardware: Obtain a PC, MTL PCS45 software, and PCL45USB interface.
- Verify Input Types: Identify the connected thermocouple or millivolt source.
- Select Linearisation: Configure the correct thermocouple characteristic.
- Set Measurement Range: Define the required input span and output scaling.
- Configure Compensation: Select the appropriate cold-junction compensation mode.
- Set Burnout Behaviour: Choose upscale, downscale, or off response.
- Configure Response Time: Retain the 500ms default or select a suitable alternative.
- Verify Output: Test the 4-20mA signal against the receiving analog input.
- Record Configuration: Document channel settings and commissioning results.
Engineering Note: The specification identifies 500ms as the default response time. Accuracy at 100ms or 200ms requires confirmation from Eaton's MTL product documentation.
06 | LED Diagnostics and Field Troubleshooting
The three LED indications help technicians identify operating conditions during commissioning and maintenance.
| Green LED | Power and general status indication |
| Yellow LED | Channel status indication |
| Red LED | Alarm indication |
Practical Diagnostic Recommendations
- Unexpected Output: Check the selected input type and configured measurement span.
- Temperature Offset: Verify cold-junction compensation settings and terminal connections.
- Unstable Readings: Inspect thermocouple polarity, cable routing, and grounding arrangements.
- Incorrect Burnout Response: Review the programmed sensor-failure direction.
- Output Saturation: Check input range configuration and the connected loop load.
- Communication Problems: Inspect the PC interface and configuration software connection.
07 | System Integration and Application Compatibility
The MTL4576-THC converts hazardous-area temperature measurements into a standard current signal. Its output supports integration with compatible safe-area instrumentation.
- PLC Systems: Connect the 4-20mA output to compatible analog input modules.
- DCS Platforms: Transfer temperature measurements into process control channels.
- SCADA Systems: Provide measurement signals through compatible control-system interfaces.
- Industrial Instrumentation: Support temperature monitoring and process indication.
- Hazardous-Area Sensors: Accept supported thermocouple signals from specified hazardous locations.
Check loop load, input impedance, wiring resistance, and safety parameters before system integration. The maximum nominal output load is 300Ω.
08 | Intrinsic Safety and Installation Considerations
The module is specified for hazardous-area signal sources in the following applications:
- Gas Group: IIC.
- Equipment Protection: T4–T6 temperature classes, subject to certification details.
- IEC Zone: Zone 0 application.
- North American Classification: Division 1, Group A application.
- Maximum External Voltage: Um = 253V rms or DC.
Always consult the applicable certificate for intrinsic safety parameters. Verify the complete loop design, entity parameters, grounding, and installation requirements before energising the system.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.