Home MIDAS-E-H2X Honeywell Midas Gas Detector Sensor Cartridge
MIDAS-E-H2X
MIDAS-E-H2X
MIDAS-E-H2X
MIDAS-E-H2X

MIDAS-E-H2X Honeywell Midas Gas Detector Sensor Cartridge

  • Manufacturer: Honeywell

  • Product No.: MIDAS-E-H2X

  • Condition: In stock

  • Product Type: Gas Detector Sensor

  • Product Origin: UK

  • Payment: T/T, Western Union

  • Weight: 100g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

MIDAS-E-H2X Honeywell Midas Hydrogen Gas Sensor Cartridge Technical Specifications

The Honeywell MIDAS-E-H2X is a plug-and-play, 3-electrode electrochemical sensor cartridge engineered for high-precision detection of trace Hydrogen ($H_2$) gas leaks. Designed strictly for the Honeywell Midas transmitter series, this cartridge utilizes an internal micro-amperometric cell that generates a linear current output proportional to the partial pressure of ambient Hydrogen. The MIDAS-E-H2X features a calibrated measuring scale of 0 to 1000 ppm with a baseline resolution of 5 ppm, ensuring early-stage monitoring below standard lower explosive limits (LEL). Its integrated factory-coded EEPROM stores calibration offsets, serial tracking numbers, and manufacturing dates, enabling instant transmitter synchronization upon field installation without requiring manual gas adjustments.

Global PLC Spare HUB's Insight

In high-purity industrial loops like semiconductor cleanrooms and battery storage rooms, tracking ambient $H_2$ levels requires continuous stability to avoid false alarm cross-tripping. The Honeywell MIDAS-E-H2X addresses this via its internal reference electrode, which stabilizes baseline drifting even under fluctuating humidity profiles (10% to 90% RH). Compared to older solid-state sensors that suffer from thermal runaway, the 3-electrode chemistry maintains a zero-drift profile of less than 0.17 ppm/°C. Plant engineers can leverage this predictability to extend calibration intervals up to 6 months, lowering the total cost of ownership across active gas safety infrastructures.

Sensor Architecture & Key Parametric Data

The operational framework of the MIDAS-E-H2X sensor is defined by the following electrical and environmental boundaries:

Engineering Classification Operational Threshold Value
Brand Manufacturer Honeywell Analytics
Cartridge Model Code MIDAS-E-H2X
Detection Technology 3-Electrode Electrochemical Cell
Calibrated Range 0 to 1000 ppm Hydrogen ($H_2$)
Lower Detection Limit (LDL) 90 ppm baseline threshold
Minimum Alarm 1 Setpoint 120 ppm factory default target
Dynamic Resolution 5 ppm incremental step
Response Time ($t_{62.5}$) Less than or equal to 50 seconds
Loop Linearity & Repeatability Within <±5% of active measured value
Operating Temperature Scope 0°C to +40°C (32°F to 104°F)
Ambient Pressure Window 90 kPa to 110 kPa absolute pressure
Typical Cell Life Expectancy Greater than or equal to 24 months under normal deployment

Target Applications & Machine Scenarios

The MIDAS-E-H2X module provides dedicated toxic and explosive risk protection in these primary settings:

  • Semiconductor Fabrication Plants: Monitors gas cabinets, chemical vapor deposition (CVD) tools, and exhaust gas lines utilizing Hydrogen process streams.
  • Battery Energy Storage Systems (BESS): Detects off-gas indicators during thermal runaway anomalies in lithium-ion and lead-acid battery banks.
  • Industrial Electrolyzer Skids: Integrates into automated machinery cells dedicated to green Hydrogen generation and gas bottling distribution points.
  • Metallurgical Heat-Treating Furnaces: Tracks ambient escape levels in annealing furnaces using reducing atmospheres.

Diagnostic Capacities & Signal Validation

  • Electronic End-of-Life Counter: Continuously syncs data with the Midas transmitter to monitor operational days and project remaining cell life.
  • Electronic Cartridge Validation: Validates internal sensor bridge continuity automatically upon initialization, generating "Fault Code F01" if cell impedance degrades.
  • Temperature Compensating Matrix: The transmitter reads the cartridge's temperature tracking diode, compensating for sensitivity swings (<±3% of value/°C) in real time.
  • Fast System Warm-Up: Reaches full analytical stabilization in less than 10 minutes from a cold power-on sequence.

Procurement, Warranty, & Global Logistics Logistics

  • Factory Fresh Storage Assurance: All inventory cells are held in temperature-regulated facilities (+5°C to +25°C) to prevent premature electrolyte evaporation prior to deployment.
  • Warranty Safeguard: Covered by a comprehensive 12-month industrial quality warranty starting from the physical delivery date.
  • Expedited Air Freight: Global shipping is fulfilled via premier international carriers including DHL, FedEx, and UPS.
  • Order Handling Speed: Standard warehouse units are packed and tracking details uploaded within 24 to 48 hours of confirmation.

Frequently Asked Questions

How can field engineers verify that the internal sensor electrolyte has not degraded over time?

Perform a standardized bump test or full calibration cycle using certified Hydrogen target gas. If the transmitter displays an "Under Sensitive" error or fails to reach the 90 ppm lower detection threshold during testing, the internal electrochemical chemistry has depleted, and the cartridge must be replaced.

Can this cell be safely used in sub-zero applications like outdoor cryogenic storage yards?

No, this model is certified for an operating temperature range of 0°C to +40°C. Deploying the cartridge below 0°C risks freezing the aqueous electrolyte matrix, which causes slow response times, false baseline shifts, or physical leakage through the cell membranes.

What is the proper procedure for storing spare cartridges to ensure maximum shelf life?

Keep the spare cells sealed in their original bags and store them in a cool environment between +5°C and +25°C. Never unpack a cartridge until the moment of installation, as exposure to dry air accelerates the gradual dehydration of the internal electrochemical cell.

Will exposure to background solvents like Isopropyl Alcohol (IPA) trigger false alarms on this sensor?

Yes, electrochemical cells can cross-react with other oxidizable vapors like alcohols, Carbon Monoxide, or unsaturated hydrocarbons. In cleanroom environments, it is recommended to space sensors away from tool washdown stations to prevent false high alarms.

What is the technical significance of the 3-electrode design compared to older 2-electrode modules?

The third electrode acts as a reference point that maintains a stable internal bias voltage against the working electrode. This prevents the sensor baseline from drifting when gas concentrations change rapidly, allowing for more consistent accuracy over its 24-month lifespan.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.