  • Manufacturer: GE Fanuc

  • Product No.: IC694MDL734

  • Condition: In stock

  • Product Type: Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Overview

The IC694MDL734 is an advanced discrete output module engineered by GE Fanuc within the high-performance RX3i PacSystem architecture. Featuring 6 isolated channels capable of handling both positive and negative logic configurations, this versatile module safely interfaces PLC logic commands with demanding field actuators across a wide DC operating voltage span.

Configuration Breakdown & Technical Specifications

  • Brand: GE Fanuc
  • Manufacturer Part Number: IC694MDL734
  • Product Series: RX3i PacSystem
  • Module Type: Discrete Output Module (Positive/Negative Logic)
  • Number of Outputs: 6 isolated channels
  • Nominal Voltage: 125V DC
  • Operating Voltage Range: 10.8 to 150 VDC
  • Output Current: 1.0 Amp per point
  • Inrush Current Limit: 7 Amps per 100 ms at 2% duty cycle
  • Switching Response Time: 5 to 7 milliseconds (ON/OFF)
  • Backplane Power Draw: 90 mA maximum sourced from 5V DC bus
  • Dielectric Isolation: 250V AC continuous, 1500V AC for 1 minute (point-to-point and backplane-to-ground)
  • Internal Protection: Fuse-free electronic point design

Packaging List & Commercial Terms

  • One IC694MDL734 PACSystems RX3i output module unit
  • Plug-in removable terminal block connector block
  • Factory compliance documentation and installation guide
  • Warranty: Full 12-month comprehensive replacement coverage
  • Fulfillment: Express priority global delivery via FedEx, UPS, and DHL within 24-48 hours

Target Machinery & Application Scenarios

  • Heavy industrial DC solenoid valves and actuator control loops.
  • Process manufacturing plant alarm annunciator and indicator lamp grids.
  • Substation auxiliary DC control power switching architectures.
  • Multi-voltage discrete interlock systems requiring flexible sinking and sourcing logic.

Diagnostic Capability

  • Individual front-panel LED status indicators provide immediate visual verification of active output states per channel.
  • Backplane communication link monitoring allows the RX3i CPU to flag rack backplane faults instantly.
  • Robust optical and dielectric isolation protects internal controller logic from high-voltage field transients and ground loops.

Global PLC Spare HUB's Insight

When deploying the IC694MDL734 in high-inductance DC switching applications, instrumentation engineers must install external flyback diodes across inductive loads. Because the module lacks internal fusing, protecting the 1 Amp per point circuits with appropriately rated fast-acting external fuses prevents catastrophic trace damage during severe field short circuits.

Frequently Asked Questions

Question: Can this module handle AC field voltages given its wide DC range?

Answer: No, the module is strictly rated and engineered for DC voltage applications spanning 10.8 to 150 VDC and cannot be used with AC power sources.

Question: What precautions are necessary when wiring mixed logic configurations?

Answer: Ensure that common power supply references are properly separated across isolated banks to prevent unintended ground faults in mixed positive and negative logic layouts.

Question: How does the lack of onboard fusing impact maintenance planning?

Answer: Technicians must ensure external loop protection fuses are installed in series with each output point to safeguard against overcurrent faults.

Question: What causes an RX3i backplane power budget fault with this unit?

Answer: Exceeding the total 5V DC bus capacity of the rack power supply by stacking multiple high-draw modules without a auxiliary power supply can trigger power faults.

Question: Can the module be inserted into a powered RX3i backplane rack?

Answer: While RX3i systems support hot insertion in specific configurations, standard engineering practice dictates powering down the rack to prevent bus terminal arcing.

Buying Guide

  • Verify that your field actuator operating voltages fall strictly within the 10.8 to 150 VDC envelope before integration.
  • Confirm available slot capacity and 5V DC backplane power supply loading inside your existing RX3i rack layout.
  • Select expedited shipping via DHL or FedEx to eliminate project delays during critical plant turnaround windows.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.