IC693CPU367 GE Fanuc Series 90-30 PROFIBUS-DP CPU
Manufacturer: GE
Product No.: IC693CPU367
Condition: In stock
Product Type: CPU Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Product Overview | PROFIBUS-DP Communication CPU
GE Fanuc IC693CPU367 is a Central Processing Unit from the Series 90-30 PLC platform. It operates as a PROFIBUS-DP slave device within industrial automation networks.
The processor exchanges cyclic data with a PROFIBUS-DP master. It receives master commands and returns configured process data. This architecture supports distributed control and centralized process supervision.
The module uses an 80386EX processor and provides 240 KB of register memory. Its discrete I/O capacity reaches 4,096 points. An RS-232 serial interface supports configuration and firmware-related service operations.
01 | Hardware Identity and Core Specifications
| Manufacturer | GE Fanuc |
| Model | IC693CPU367 |
| Product Series | Series 90-30 |
| Product Type | PLC Central Processing Unit |
| Network Role | PROFIBUS-DP Slave |
| Processor | 80386EX |
| Register Memory | 240 KB |
| Discrete I/O Capacity | 4,096 points |
| Floating-Point Mathematics | Supported |
| Serial Interface | RS-232 |
| Backplane Current | 940 mA at 5 VDC |
| Minimum CPU Version | 10.72 or later |
| Configuration Software | Version 5.0 or later |
02 | PROFIBUS-DP Network Architecture
The IC693CPU367 operates as a slave on a PROFIBUS-DP network. A configured master controls the communication cycle and exchanges process data with the slave.
Communication structure:
- Master device: Initiates and manages bus communication.
- IC693CPU367: Operates as the configured slave device.
- Input data: Transfers configured slave data to the master.
- Output data: Receives process data from the master.
- Network diagnostics: LED indicators help technicians inspect communication status.
The slave does not control PROFIBUS-DP bus parameters. Engineers must configure network properties at the master level.
03 | Supported PROFIBUS-DP Transmission Rates
The module supports multiple transmission rates for different network configurations.
| Category | Supported Data Rate |
| Low Speed | 9.6 kbps |
| Low Speed | 19.2 kbps |
| Low Speed | 93.75 kbps |
| Medium Speed | 187.5 kbps |
| Medium Speed | 500 kbps |
| High Speed | 1.5 Mbps |
| High Speed | 3 Mbps |
| High Speed | 6 Mbps |
| High Speed | 12 Mbps |
Set the network baud rate according to the master configuration and supported network hardware. All participating devices must use compatible communication settings.
04 | Processor Performance and Data Handling
- 80386EX architecture: Provides the processor platform for PLC operations.
- 240 KB register memory: Supports configured data storage and register operations.
- 4,096 discrete points: Defines the stated discrete I/O capacity.
- Floating-point support: Enables floating-point calculations within supported applications.
- RS-232 interface: Provides a serial connection for supported service operations.
Actual application capacity depends on the PLC configuration, program requirements, and communication data mapping.
05 | Installation and Network Commissioning
Follow the established Series 90-30 installation procedures before commissioning.
- Hardware inspection: Check the CPU and rack for physical damage.
- Rack verification: Confirm the installation position and backplane compatibility.
- Power assessment: Reserve the required 940 mA at 5 VDC.
- CPU installation: Install the module according to the manufacturer's instructions.
- Software preparation: Use compatible configuration software, version 5.0 or later.
- CPU verification: Confirm CPU firmware version 10.72 or later.
- Network configuration: Set the PROFIBUS-DP master parameters.
- Slave integration: Configure the device address and process data mapping.
- Communication testing: Verify cyclic data exchange and diagnostic indicators.
- Application testing: Confirm the correct data transfer before production operation.
06 | Diagnostic Functions and Maintenance
Network diagnostics help maintenance engineers identify communication problems during commissioning and operation.
| Diagnostic Area | Recommended Check |
| Network status | Observe the module's LED indicators. |
| Communication settings | Compare baud rate and network parameters. |
| Slave addressing | Verify the configured device address. |
| Data exchange | Compare master and slave process data. |
| Power supply | Check the 5 VDC backplane supply. |
| Serial interface | Inspect the RS-232 connection during service. |
When communication fails, check the master configuration first. Then inspect the slave address, transmission rate, cabling, and data mapping.
07 | Operating Environment
| Environmental Parameter | Specified Range |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Backplane Voltage | 5 VDC |
| Backplane Current Consumption | 940 mA |
Maintain the specified operating temperature during normal service. Follow the manufacturer's cabinet ventilation and environmental installation requirements.
08 | Compatibility and Configuration Requirements
- PLC platform: GE Fanuc Series 90-30.
- CPU firmware: Version 10.72 or later.
- Configuration software: Version 5.0 or later.
- Network protocol: PROFIBUS-DP.
- Network role: Slave device.
- Serial connection: RS-232.
Before replacement, compare the complete part number and firmware requirements. Verify the rack configuration, master communication settings, and application data mapping.
09 | Supply, Warranty and Logistics
| Product | GE Fanuc IC693CPU367 |
| Description | Series 90-30 PROFIBUS-DP Slave CPU |
| Packaging | New & Original in Factory Packing |
| Warranty | Factory Warranty: 12 Months |
| Shipping Carriers | FedEx, UPS, and DHL |
| Dispatch Time | 24–48 hours, subject to stock confirmation |
Contact our sales team for current stock, pricing, and delivery arrangements. Include your CPU version and application requirements when requesting a quotation.
Professional FAQ | Application and Troubleshooting
1. What happens if the PROFIBUS-DP master uses an unsupported transmission rate?
The network may fail to establish reliable communication. Check the supported rates and compare the master configuration with the connected slave devices. Correct the settings before testing data exchange.
2. How should engineers investigate intermittent communication interruptions?
Start by reviewing network diagnostics and master-side error records. Inspect cable connections, bus termination, grounding, and electromagnetic interference. Also check whether the network baud rate matches the installation requirements.
3. Why is firmware verification important when replacing this processor?
Different firmware versions may affect configuration compatibility and application behavior. Verify the installed version against the project requirements. The specified minimum version is 10.72.
4. What should engineers verify when the master receives incorrect process data?
Inspect the slave data mapping, configured data length, and address assignments. Compare the transmitted values with the PLC application variables. Also check data scaling and byte ordering where applicable.
5. What information should buyers provide when sourcing a replacement CPU?
Provide the complete IC693CPU367 part number, firmware version, Series 90-30 rack details, and PROFIBUS-DP master model. Include the existing network baud rate when available. These details help assess replacement compatibility before purchase.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.