Home IC200MDL930 GE Fanuc VersaMax 8-Point Relay Output Module

IC200MDL930 GE Fanuc VersaMax 8-Point Relay Output Module

  • Manufacturer: GE Fanuc

  • Product No.: IC200MDL930

  • Condition: In stock

  • Product Type: Relay Output Module

  • Product Origin: USA

  • Payment: T/T, Western Union

  • Weight: 240g

  • Shipping port: Xiamen

  • Warranty: 12 months

Selected quantity: 1
Request a quote

Estimate delivery times: 12-26 days (International), 3-6 days (United States).

Return within 30 days of purchase. Duties & taxes are non-refundable.

Guaranteed Safe Checkout

Visa
PayPal
Mastercard
American Express

Product Introduction | Industrial Relay Switching Platform

GE Fanuc IC200MDL930 is an 8-point relay output module from the VersaMax I/O series. GE Intelligent Platforms originally developed this product. Emerson Automation currently supports the product portfolio.

The module provides eight individually isolated, normally open (Form A) relay contacts. Each output operates as a dry contact and switches an externally supplied electrical load.

Its fixed-coil, moving-armature relay design supports both AC and DC switching applications. Silver-alloy contacts provide the electrical switching interface. Individual channel isolation helps separate output circuits within the control system.

The IC200MDL930 suits industrial control applications that require independent relay switching. Typical applications include contactor control, alarm circuits, and auxiliary equipment activation.

01 | Product Identity and Hardware Architecture

Brand GE Fanuc
Part Number IC200MDL930
Product Series VersaMax I/O
Original Manufacturer GE Intelligent Platforms
Current Product Portfolio Emerson Automation
Module Type Relay Output Module
Output Points 8
Output Configuration Individually Isolated
Contact Arrangement Normally Open (Form A)
Relay Mechanism Fixed Coil, Moving Armature
Contact Material Silver Alloy
Output Type Dry Relay Contacts
Switching Frequency 20 cycles per minute
Maximum Response Time 10 ms

02 | Electrical Load Selection Matrix

The relay contacts support different external AC and DC voltage circuits. Engineers must select the load according to the applicable voltage and current limits.

Electrical Parameter Rated Specification
Nominal DC Voltage 5 / 24 / 125 VDC
Nominal AC Voltage 120 / 240 VAC
DC Switching Range 0 to 125 VDC
AC Switching Range 0 to 265 VAC
AC Frequency 47 to 63 Hz
Minimum Contact Current 10 mA per point
Maximum AC Contact Current 2.0 A at 5 to 265 VAC
Maximum DC Contact Current 2.0 A at 5 to 30 VDC
High-Voltage DC Current 0.2 A at 31 to 125 VDC

Important: The listed maximum contact currents apply to resistive loads. Do not apply the same current ratings to inductive loads without checking the manufacturer's load derating requirements.

03 | Relay Switching Characteristics

 

The dry-contact architecture allows engineers to select suitable external load supplies. The connected circuit must remain within the specified contact ratings.

04 | Electrical Isolation and Protection

Isolation Category Specification
User Input to Logic and Frame Ground 250 VAC continuous
User Input to Logic and Frame Ground 1500 VAC for 1 minute
Group-to-Group Isolation 250 VAC continuous
Group-to-Group Isolation 1500 VAC for 1 minute
Output Isolation Arrangement Individually Isolated

Protection considerations:

  • The module does not include internal output fuses.
  • The module does not include internal snubber circuits.
  • Provide suitable external branch-circuit protection.
  • Use appropriate suppression for inductive loads.
  • Check load inrush current before selecting the output circuit.
  • Follow applicable electrical protection and wiring standards.

Contactors, solenoids, and electromagnetic loads can generate switching transients. External suppression helps reduce electrical stress on relay contacts.

05 | Backplane Power and Operating Conditions

Parameter Specification
Backplane Voltage 5 VDC
Backplane Current Consumption 243 mA (listed specification)
Current Draw with Outputs Energized Approximately 245 mA (additional supplied specification)
Operating Temperature 0 to 30°C
Cooling Requirement Forced Air Cooling

Maintain adequate cabinet ventilation during continuous operation. Monitor ambient temperature when installing multiple modules in a compact enclosure.

Thermal derating may apply when operating conditions exceed the specified temperature limit. Consult the manufacturer's installation documentation before using the module outside its stated range.

06 | VersaMax System Installation

Install the module in the compatible VersaMax I/O system. Verify the backplane and terminal assembly before connecting field circuits.

  1. System Check: Confirm the VersaMax rack and installation configuration.
  2. Power Isolation: Disconnect relevant control and field power supplies.
  3. Module Positioning: Identify the correct mounting position.
  4. Hardware Installation: Secure the module according to manufacturer instructions.
  5. Wiring Preparation: Identify all eight output circuits.
  6. Load Verification: Check voltage, current, and load characteristics.
  7. Protection Setup: Install suitable fuses and suppression devices.
  8. Commissioning: Test each relay output individually.

Keep field wiring consistent with the project electrical drawings. Clearly identify each output channel to simplify commissioning and maintenance.

07 | LED Diagnostics and Maintenance

The module provides individual channel indicators and a module OK indicator.

Indicator Diagnostic Purpose
Individual Channel LEDs Show the energization status of corresponding output channels.
Module OK LED Indicates the module's backplane power and operating status.

Recommended maintenance checks:

  • Compare channel LED status with PLC output commands.
  • Inspect relay terminals for loose connections.
  • Check contact performance during scheduled maintenance.
  • Inspect external suppression and protection components.
  • Review load current against the specified contact limits.
  • Check cabinet ventilation and operating temperature.

If an output fails to switch, inspect the field supply and external wiring first. Then check the PLC command, terminal connections, and relay contact condition.

08 | Industrial Applications

  • Motor Control: Switching compatible contactor control circuits.
  • Process Automation: Activating auxiliary process equipment.
  • Alarm Systems: Controlling external alarm and annunciation circuits.
  • Machine Control: Switching independently controlled electrical loads.
  • Utility Systems: Operating compatible auxiliary electrical equipment.
  • Industrial Panels: Providing isolated relay outputs for control cabinets.

Verify the electrical load characteristics before assigning each output. Application suitability depends on voltage, current, switching frequency, and load type.

09 | Standards and Compliance

Compliance Standard Specification
CE Specified
cULus Specified

Confirm the applicable product revision and certification documentation for the installation region. Follow local electrical codes and system-level compliance requirements.

10 | Product Supply and Commercial Information

  • Product: GE Fanuc IC200MDL930.
  • Series: VersaMax I/O.
  • Description: 8-Point Individually Isolated Relay Output Module.
  • Packaging: New & Original in Factory Packing.
  • Warranty: Factory Warranty: 12 Months.
  • Shipping: FedEx, UPS, and DHL.
  • Dispatch: 24–48 hours, subject to stock confirmation.

Contact our sales team for quotation, availability, and technical assistance. Provide your application voltage and load requirements for additional selection support.

Global PLC Spare HUB | Relay Application Insight

The IC200MDL930 provides eight independent Form A relay outputs for AC and DC load switching. Its individual isolation structure supports separate field circuits within a VersaMax control installation.

One important engineering consideration is the difference between resistive and inductive loads. Contact current ratings cannot be transferred directly between these load categories.

For inductive applications, engineers should evaluate inrush current, switching transients, and contact protection. The absence of internal fuses and snubbers makes external circuit protection an important design requirement.

Proper load selection and thermal management help maintain reliable relay operation. These checks should form part of the initial design and periodic maintenance procedures.

Professional FAQ | Relay Selection and Field Engineering

1. Why should the minimum contact current be considered when selecting connected loads?

The specified minimum contact current is 10 mA per point. Loads below this value may not provide reliable contact performance under all conditions. Check the actual load current before connecting low-current electronic inputs.

2. Can one output control a contactor coil directly?

It depends on the coil's voltage, steady-state current, and inrush characteristics. Compare these values with the relay contact ratings. Provide suitable external suppression when required. Use an interposing relay when the load exceeds the permitted switching conditions.

3. What should technicians investigate when an LED indicates an active output but the load does not operate?

Check the external field supply first. Then inspect the load fuse, terminal wiring, and contact continuity. An illuminated channel indicator does not independently confirm that the external load circuit is complete.

4. How should engineers distribute loads across the eight output points?

Calculate each circuit's operating current and inrush demand. Keep every channel within its applicable voltage and current limits. Consider the load type and switching frequency when assigning channels. Provide individual branch protection where required by the electrical design.

5. What should be evaluated when replacing this module in an operating VersaMax system?

Compare the exact catalog number and hardware configuration. Review the terminal arrangement, field wiring, PLC output assignments, and connected load ratings. Plan a controlled shutdown and test each output after installation. Confirm that the replacement meets the existing system's electrical requirements.

Tags

Q: Are these parts 100% original and new?

A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.

Q: How fast is the shipping to my country?

A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.

Q: Can I get a formal quotation with shipping costs?

A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.

Q: Do you offer discounts for bulk orders?

A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.




12-Month Comprehensive Warranty

Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.

  • Coverage: Functional defects and hardware failures under normal operating conditions.
  • Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.

Returns & Exchange Policy

We offer a 30-day return policy to ensure you receive the exact part your system requires.

  • Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
  • RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
  • Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.

Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.