499AOZ-54-VP Rosemount 499 Dissolved Ozone Sensor Water Analyzer
Manufacturer: Rosemount
Product No.: 499AOZ-54-VP
Condition: In stock
Product Type: Dissolved Ozone Sensor
Product Origin: USA
Payment: T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
499AOZ-54-VP Advanced Dissolved Ozone Monitoring Sensor
Rosemount 499AOZ-54-VP provides high-precision dissolved ozone measurement for industrial liquid analysis systems.
The sensor supports stable ozone monitoring across water treatment and food processing environments.
This platform combines fast response performance with durable chemical-resistant construction.
The VP6 quick disconnect configuration simplifies installation and maintenance procedures.
The sensor architecture supports reliable long-term analytical performance under continuous operation.
Its membrane-based sensing design improves repeatability and process stability.
Global PLC Spare HUB's Insight
499AOZ-54-VP performs reliably in demanding dissolved ozone monitoring applications.
Process engineers value its stable linearity during continuous disinfection control.
The VP quick-connect design reduces calibration downtime during maintenance cycles.
Its robust wetted materials support aggressive process media environments.
Technicians frequently deploy this model in municipal and industrial sanitation systems.
The sensor integrates efficiently with Rosemount analytical transmitters.
Sensor Platform Highlights
- Brand: Rosemount
- Model: 499AOZ-54-VP
- Series: Rosemount 499 Series
- Sensor Type: Dissolved Ozone Sensor
- VP6 quick disconnect fitting configuration
- Compatible with Rosemount 1056 and 1066-DO analyzers
- Compatible with Rosemount 56 and 5081-A systems
- Fast-response membrane sensing technology
- High repeatability analytical performance
- Chemical-resistant wetted material construction
- Flow-through and open-channel installation support
- Designed for industrial sanitation applications
- Extended cable installation capability
- Field-serviceable membrane assembly structure
Analytical Measurement Specifications
- Measurement Range: 0 to 3 ppm (mg/L) as O3
- Operating Pressure: 0 to 65 psig
- Operating Temperature: 0°C to 50°C
- Process Connection: 1-inch MNPT
- Wetted Materials: Polysulfone, Viton®, Teflon®, Silicone
- Linearity: ±5% of reading or ±3 ppb
- Repeatability: ±2% of reading
- Response Time: 30 seconds to 90% response
- Electrolyte Volume: Approximately 25 mL
- Electrolyte Life: Approximately 3 months
- Recommended Electrolyte Replacement: Monthly
- Maximum Cable Length: 300 ft.
- Standard Cable Support: Up to 100 ft.
- Flow-Through Sample Rate: 1 to 5 gpm
- Open Channel Velocity: 1 ft./sec
- Low Flow Cell Rate: 2 to 5 gph
- Shipping Weight: 3 lb.
Recommended Application Environments
- Municipal drinking water treatment
- Food and beverage sanitation systems
- Industrial ozone disinfection processes
- Bottled water production facilities
- Clean-in-place process systems
- Cooling water treatment applications
- Pharmaceutical purified water systems
- Industrial wastewater treatment plants
- Aquaculture water quality management
Diagnostic and Monitoring Capabilities
- Continuous dissolved ozone verification
- Stable low-level concentration monitoring
- Fast process upset response detection
- Membrane condition performance evaluation
- Calibration consistency validation
- Flow condition monitoring support
- Long-distance signal transmission capability
- Sensor stability trend observation
Maintenance and Engineering Advantages
- The VP6 connector simplifies sensor replacement procedures.
- Membrane assemblies support rapid field servicing.
- Stable repeatability improves process control consistency.
- Chemical-resistant materials extend operational durability.
- Fast response improves disinfection process optimization.
- Long cable support enables flexible installation layouts.
Included Service Components
- 1 × 499AOZ-54-VP Dissolved Ozone Sensor
- 3 × Replacement membrane assemblies
- 3 × Replacement O-rings
- 1 × Electrolyte solution bottle
- Factory-prepared sensor assembly
Shipping and Warranty Service
- Fast dispatch within 24-48 hours
- Worldwide shipping support available
- FedEx, UPS, and DHL delivery options provided
- Protective industrial export packaging included
- 12-month warranty service supported
- Technical assistance available after shipment
Professional FAQ
Why is dissolved ozone monitoring critical in sanitation systems?
Accurate ozone control improves disinfection efficiency and process safety consistency.
How can engineers improve membrane sensor stability?
Maintain stable sample flow conditions and replace electrolyte regularly.
Which installations benefit most from VP6 quick-disconnect fittings?
Frequent maintenance environments benefit from faster sensor replacement procedures.
What should technicians evaluate before selecting sample flow configuration?
Process pressure, response speed, and installation space determine flow arrangement suitability.
Why is repeatability important in dissolved ozone applications?
Stable repeatability improves dosing consistency and regulatory process compliance.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.