190501-08-00-00 Bently Nevada 190501 Velomitor CT Velocity Sensor
Manufacturer: Bently Nevada
Product No.: 190501-08-00-00
Condition: In stock
Product Type: Velomitor CT Velocity Transducer
Product Origin: USA
Payment: T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
Bently Nevada 190501-08-00-00 | Velomitor CT Velocity Transducer
The Bently Nevada 190501-08-00-00 is a Velomitor CT velocity transducer designed for industrial machine vibration monitoring. It provides a velocity-proportional output for vibration measurement systems.
The transducer has a nominal sensitivity of 3.94 mV/mm/s (100 mV/in/s), with a specified tolerance of ±5%. Its frequency response extends from 3 Hz to 900 Hz within ±1.0 dB. This makes it suitable for machinery vibration measurements across a broad operating frequency range.
The 190501 configuration uses a plate stud mounting arrangement, a MIL-C-5015 connector interface and no agency approval option. Its 316L stainless steel housing supports demanding industrial installation environments.
01 | Model Configuration Breakdown
The complete part number identifies the transducer family and its ordering options. The suffixes should be checked before ordering replacement units.
| Configuration Segment | Code | Description |
| Product Series | 190501 | Velomitor CT Velocity Transducer |
| Mounting Hardware | 08 | Plate stud, 3/8-24 to 1/2-20 |
| Connection Option | 00 | MIL-C-5015 connection interface |
| Agency Approval | 00 | No agency approvals |
Ordering code structure:
-
190501 – Velomitor CT product family
- -08 – Plate stud mounting hardware, 3/8-24 to 1/2-20
- -00 – MIL-C-5015 connector interface
- -00 – No agency approval option
Complete ordering number: 190501-08-00-00
Important selection note: The supplied configuration ends in approval code 00. It does not include the hazardous-area approvals listed for options 01 through 04. Do not substitute an approved configuration without checking the project certification requirements.
02 | Measurement Performance
| Electrical Parameter | Specification |
| Nominal sensitivity | 3.94 mV/mm/s (100 mV/in/s) |
| Sensitivity tolerance | ±5% |
| Frequency response, ±1.0 dB | 3.0 Hz to 900 Hz |
| Frequency response, ±3.0 dB | 1.5 Hz to 1.0 kHz |
| Temperature sensitivity | -8% to +5% typical over the operating temperature range |
| Transverse response | Less than 5% of axial sensitivity |
| Amplitude linearity | ±2% up to 63.5 mm/s peak |
| Mounted resonant frequency | 9 kHz minimum, stud mounted, except quick disconnect |
| Output bias voltage | 10.1 VDC ±1.0 VDC, Pin A referenced to Pin B |
| Dynamic output impedance | Less than 400 Ω typical |
| Broadband noise | 0.229 mm/s peak |
| Base strain sensitivity | 0.43 mm/s/μstrain |
| Maximum cable length | 305 m (1,000 ft.) using cable part number 02173006, without signal degradation |
The sensitivity specification defines the relationship between mechanical velocity and electrical output. It is important when checking monitor scaling and replacement compatibility.
The frequency response describes the measurement range within specified amplitude tolerances. For applications requiring tighter amplitude accuracy, use the ±1.0 dB range as the primary reference.
The transverse response is less than 5% of axial sensitivity. Correct mounting orientation and a stable mounting surface remain important for reliable measurements.
03 | Connector, Polarity and Electrical Interface
| Interface Item | Specification |
| Connector | 2-pin MIL-C-5015, 316L stainless steel, top-mounted |
| Connector option | 00 |
| Output bias | 10.1 VDC ±1.0 VDC |
| Output impedance | Less than 400 Ω typical |
| Polarity | Pin A goes positive relative to Pin B when velocity is from the transducer base to its top |
| Grounding | Internal electronics isolated from the case |
| Specified cable | 02173006 |
| Maximum cable length | 305 m (1,000 ft.) without signal degradation |
Check connector condition, pin assignment and cable continuity during installation. Incorrect polarity can reverse the output phase relative to the machine vibration direction.
The internal electronics are isolated from the case. Avoid assuming that the transducer housing and signal return are electrically interchangeable.
04 | Mechanical Construction and Installation
| Mechanical Item | Specification |
| Housing material | 316L stainless steel |
| Weight | Less than 297 g (10.5 oz.), typical |
| Mounting surface | 33 mm diameter |
| Height | 82 mm |
| Mounting hardware | Plate stud, 3/8-24 to 1/2-20 |
| Mounting torque | 4.5 N·m ±0.6 N·m (40 in-lbf ±5 in-lbf) |
| Mounting orientation | Any orientation |
Installation checks:
- Inspect the mounting surface for contamination, corrosion and mechanical damage.
- Confirm the mounting stud thread matches the installation hardware.
- Apply the specified mounting torque of 4.5 N·m ±0.6 N·m.
- Check that the transducer is firmly seated against the mounting surface.
- Connect the MIL-C-5015 interface and verify the pin assignment.
- Check the monitor input scaling against the nominal sensitivity.
- Compare the measured vibration with an independent reference instrument when commissioning.
A loose mounting interface can affect the measured vibration response. Poor surface contact may also introduce unwanted mechanical resonance or inconsistent readings.
05 | Environmental Operating Limits
| Environmental Parameter | Specification |
| Operating temperature | -40°C to +85°C |
| Storage temperature | -40°C to +100°C |
| Shock limit | 5,000 g peak maximum |
| Humidity limit | 100% condensing, non-submerged |
| Magnetic field susceptibility | Less than 0.0068 mm/s/gauss at 50 gauss, 50–60 Hz |
The 316L stainless steel construction is suitable for industrial machinery installations. The specified humidity limit permits condensing conditions but does not indicate suitability for permanent submersion.
06 | Agency Approval Configuration
The 190501 product family has agency approval options. The supplied 190501-08-00-00 ordering code specifies approval option 00, meaning no agency approvals.
For reference, the supplied documentation lists the following hazardous-area approval information for applicable options 01 through 04:
- Intrinsically safe: Ex ia IIC T4.
- North American classification: Class I, Division 1, Groups A, B, C and D; Class II, Groups E, F and G; Class III.
- Additional marking: AEx ia IIC T4, with the listed North American classifications.
- Intrinsically safe and nonincendive: Ex nL IIC T4.
- Nonincendive classification: Class I, Division 2, Groups A, B, C and D; AEx nA T4.
- Installation reference: Drawing 167536.
- Listed temperature range: -40°C to +100°C for the applicable approval configurations.
These approval descriptions do not apply automatically to the 00 configuration. Confirm the exact approval suffix and installation drawing before use in classified areas.
07 | Reliability and Replacement Considerations
When selecting a replacement velocity transducer, verify more than the product family. The mounting thread, connector interface, sensitivity, frequency response and approval suffix must match the application.
- Confirm the nominal sensitivity and monitor input scaling.
- Check the required vibration frequency range.
- Match the mounting hardware and stud thread.
- Verify the MIL-C-5015 connector and pin arrangement.
- Confirm the cable type and installed cable length.
- Check hazardous-area certification requirements.
A transducer with a similar appearance may have a different connector or approval configuration. Always compare the complete ordering number before placing a replacement order.
08 | Technical FAQ
Q1: Can the 190501 be installed directly on a machine casing with a painted or coated surface?
A painted or coated surface may prevent proper mechanical contact. Prepare a suitable mounting surface according to the equipment and installation requirements. Check surface flatness and rigidity before tightening the stud. A stable mounting interface is important for repeatable vibration measurements.
Q2: How can engineers determine whether an abnormal reading comes from the transducer or the machine itself?
Compare the reading with a calibrated portable vibration instrument at the same measurement location and direction. Inspect the mounting interface and cable before replacing the transducer. Also check the monitor input and signal conditioning. If the reference instrument confirms the vibration change, investigate the machine rather than assuming sensor failure.
Q3: Does the 190501 require a specific mounting orientation?
The specified mounting orientation is any direction. However, the measurement axis must match the intended machine vibration direction. Document the installation direction so future measurements use the same reference. Also observe the specified polarity relationship between Pin A and Pin B.
Q4: What should be checked when replacing an older Velomitor CT with this configuration?
Compare the complete part number, mounting thread, connector, sensitivity and hazardous-area requirements. Check whether the existing monitor accepts the specified bias voltage and output characteristics. Confirm cable compatibility and maximum cable length. A matching product family alone does not establish full interchangeability.
Q5: Should the 190501-08-00-00 be selected for installation in a hazardous area?
Not without further approval verification. The final 00 suffix identifies a configuration without agency approvals. The product family documentation lists other approval options, but those certifications cannot be transferred to this ordering code. For classified locations, select and verify the required approved configuration and its installation drawing before purchase.

Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.