1746-NI16I Allen Bradley PLC SLC 500 16-Channel Current Input Module
Manufacturer: Allen-Bradley
Product No.: 1746-NI16I
Condition: In stock
Product Type: Current Input Module
Product Origin: USA
Payment: T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Estimate delivery times: 12-26 days (International), 3-6 days (United States).
Return within 30 days of purchase. Duties & taxes are non-refundable.
Guaranteed Safe Checkout
1746-NI16I | Allen Bradley SLC 500 Analog Input Module
The Allen Bradley 1746-NI16I is a 16-channel analog current input module for the SLC 500 programmable controller platform. It acquires current signals from field instruments and converts them into digital values for PLC processing.
The module supports four current ranges: 0–20 mA, 4–20 mA, ±20 mA, and 0–1 mA. Engineers can use these inputs for process monitoring, equipment feedback, and closed-loop control. Its sigma-delta conversion method and programmable low-pass filtering help manage input noise and signal variation.
Designed for a single chassis slot, the 1746-NI16I provides grouped status indication and open-circuit detection capabilities. It suits SLC 500 installations that require multiple current measurements without adding separate input modules for every signal.
01 | Engineering Specification Map
| Parameter | Specification |
|---|---|
| Manufacturer | Allen Bradley |
| Product Series | SLC 500 |
| Model | 1746-NI16I |
| Module Type | 16-channel analog current input module |
| Installation Width | One chassis slot |
| Supported Current Ranges | 0–20 mA, 4–20 mA, ±20 mA, 0–1 mA |
| Resolution | 16-bit resolution, as stated in the supplied product description |
| Conversion Method | Sigma-delta |
| Bandwidth | 6–250 Hz |
| Programmable Filter Frequencies | 6, 10, 20, 40, 60, 80, 100, and 250 Hz |
| Step Response | 9–630 ms, depending on filter settings |
| Backplane Current at 5 V DC | 125 mA |
| Backplane Current at 24 V DC | 75 mA |
| Maximum Thermal Dissipation | 2.43 W |
| Input Impedance | 249 Ω, as supplied; verify the applicable hardware manual |
| Maximum Input Current | ±30 mA |
| Maximum Input Voltage | ±8 V between analog common and any input terminal |
| Common-Mode Voltage Range | ±10.25 V relative to analog common |
| Isolation | 500 V AC for 1 second |
| Operating Temperature | -25 to 60°C (-13 to 140°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Relative Humidity | 5%–95%, non-condensing |
| Status Indicators | Five green LEDs: four channel-group indicators and one module-status indicator |
| Field Wiring Connector | 25-pin D-shell AIFM connector |
| Recommended Cable | Belden 8761 or equivalent |
| Maximum Wire Size | 14 AWG, according to the supplied specifications |
| Maximum Terminal Conductors | Up to two wires per terminal, subject to terminal requirements |
| Chassis Location | Any supported I/O slot except slot 0 |
| GTIN / UPC | 10611320228196 |
| Listed Weight | Approximately 0.45 kg (1.00 lb) |
Engineering note: Confirm resolution, input impedance, isolation, and wiring limits against the official manual for the applicable module revision. Do not interpret isolation voltage as a continuous operating voltage rating.
02 | Signal Handling and Data Processing
The module converts field current signals into digital data for the SLC 500 processor. Its configurable input ranges support common transmitter and instrument interfaces.
- 4–20 mA transmitters: Suitable for many pressure, flow, level, and temperature transmitters with current outputs.
- 0–20 mA instruments: Supports compatible process devices that use a zero-based current range.
- ±20 mA signals: Supports bipolar current measurement when the connected device and channel configuration permit it.
- 0–1 mA signals: Supports compatible low-current instruments.
- Digital filtering: Select filter frequencies according to process dynamics and noise conditions.
- Data formatting: Available formats include engineering units, PID-scaled values, proportional counts, and a user-defined proportional count range for supported configurations.
Choose filter settings carefully. Lower filter frequencies can reduce signal noise, but they also increase response time. Faster settings can improve response to changing process values, but they may pass more noise.
03 | Where the 1746-NI16I Fits
| Equipment or Process | Typical Measurement | Control Purpose |
|---|---|---|
| Process skids | Pressure, flow, and level transmitter currents | Process monitoring and interlocks |
| Water and wastewater systems | Flow, pressure, and compatible analyzer outputs | Pump sequencing and process regulation |
| Conveyor systems | Load-cell transmitter or current-output sensor signals | Material flow supervision |
| HVAC and utility equipment | Compatible temperature, pressure, and flow transmitters | Equipment control and energy monitoring |
| Packaging machinery | Pressure and position-related current signals | Sequence control and process feedback |
| Industrial mixing systems | Flow, pressure, and level feedback | Batch consistency and dosing control |
| Legacy SLC 500 control panels | Multiple field current signals | Maintenance and system expansion |
These applications require compatible transmitters, correct channel configuration, and suitable PLC logic. The module does not independently perform PID control or provide safety-rated functions.
04 | Installation and Commissioning Sequence
- Confirm the chassis: Verify the SLC 500 chassis type and the available I/O slot. Do not install this module in slot 0.
- Check power capacity: Allow for 125 mA at 5 V DC and 75 mA at 24 V DC in the backplane power budget.
- Isolate equipment: Follow the site's electrical isolation procedure before installation or wiring work.
- Verify the terminal layout: Use the correct wiring diagram for the exact module revision and field connector.
- Choose the input range: Match each channel to the transmitter's output range and required measurement scaling.
- Route signal cables: Use Belden 8761 or an equivalent suitable cable. Separate analog wiring from high-noise power conductors.
- Configure filtering: Select a filter frequency that balances noise rejection and process response time.
- Scale PLC values: Check the selected data format and engineering-unit conversion in the application program.
- Test each channel: Apply known input signals and compare the PLC readings with a calibrated source or reference meter.
- Record the baseline: Document channel assignments, filter settings, input ranges, and commissioning results.
When removing the terminal block, identify its position and module type using the adjacent label. Follow the manufacturer's procedures before removing or replacing any terminal assembly.
05 | Diagnostic Logic for Maintenance Teams
| Observed Symptom | Potential Cause | Recommended Check |
|---|---|---|
| One channel reads zero | Open loop, incorrect wiring, or incorrect channel configuration | Measure loop current and verify the channel range. |
| Several channels read incorrectly | Common wiring, supply, or configuration issue | Check shared connections and compare channel settings. |
| Readings fluctuate | Electrical noise, grounding problems, or an unsuitable filter setting | Inspect cable routing, shielding, grounding, and filter selection. |
| Slow process response | Low filter frequency or slow transmitter response | Review the filter setting and the instrument's response time. |
| PLC value does not match the field instrument | Incorrect scaling, current range, or data format | Verify the raw input value and engineering-unit conversion. |
| Module status indication is abnormal | Module, chassis, or configuration problem | Check the module status, processor diagnostics, and applicable manual. |
Open-circuit detection: The supplied information identifies open-circuit detection capability. Verify the applicable channel configuration and diagnostic behavior before relying on it for maintenance alarms.
Practical diagnostic method: Compare the field current, module input data, and final scaled PLC value. This separates instrument faults from wiring problems and program-scaling errors.
06 | Global PLC Spare HUB Review
The Allen Bradley 1746-NI16I is a practical choice for SLC 500 systems that need multiple current inputs in one slot. Its main engineering value comes from channel density, configurable current ranges, and adjustable digital filtering.
Field scenario: pressure transmitter replacement
Consider a process skid with a 4–20 mA pressure transmitter. After transmitter replacement, the operator sees a pressure value that differs from the local gauge. The maintenance engineer should verify the transmitter's live current, the configured input range, and the PLC scaling calculation. If the measured current is correct but the displayed value is wrong, the scaling logic deserves attention before the module is replaced.
Field scenario: noisy flow feedback
A flow measurement fluctuates while a nearby motor starts. The engineer should inspect analog cable routing, shielding, grounding, and signal common connections. The engineer can then evaluate the filter setting against the required process response time. Increasing filtering without investigating the noise source may hide the symptom rather than correct the cause.
Selection recommendation: Before ordering, confirm the exact part number, chassis compatibility, required channel ranges, and available backplane power. Also verify the terminal assembly and field wiring requirements for the installed hardware revision.
These scenarios illustrate standard troubleshooting methods. They are engineering examples, not claims of verified customer installations.
07 | Five Professional FAQs
Q1: How can I verify the module's current measurement accuracy during commissioning?
Use a calibrated current source to apply several values within the selected range. Compare the raw module readings with the expected values before checking the PLC's engineering-unit scaling. Consult the applicable manual for accuracy tolerances and calibration requirements.
Q2: How should I choose a digital filter frequency for a pressure or flow signal?
Start with the process response requirement and the level of electrical noise. A lower cutoff can smooth unstable readings but may delay control response. Test the selected setting under normal operating conditions before finalizing the configuration.
Q3: What information should I collect before replacing a module in an operating plant?
Record the full catalog number, chassis model, slot location, terminal wiring, input ranges, data format, and filter settings. Save the existing PLC configuration and document the channel readings. These records reduce commissioning errors after replacement.
Q4: Can this module directly connect to a voltage-output sensor?
The listed input ranges are current-based. A voltage-output sensor may require a suitable signal conditioner or transmitter. Confirm the electrical interface and permitted input voltage before connecting any field device.
Q5: How do I determine whether I need the 1746-NI16I or another SLC 500 analog module?
Count the required channels and identify each signal type. Then compare current ranges, voltage support, resolution, isolation, response time, and chassis power requirements. Provide your existing module number and instrument specifications when requesting a replacement recommendation.
08 | Order Support, Shipping, and Warranty
- Product: Allen Bradley 1746-NI16I SLC 500 analog input module.
- Packaging: Protective packaging for transport. Confirm the exact included accessories when requesting a quote.
- Warranty: 12-month warranty, subject to the confirmed sales terms.
- Shipping Options: FedEx, UPS, and DHL.
- Dispatch Target: 24–48 hours after order confirmation, subject to stock and order processing.
- Quotation Support: Request current pricing, availability, lead time, and package details.
Request a quotation for the 1746-NI16I today. Include your required quantity, delivery destination, and existing SLC 500 chassis model. Global PLC Spare HUB can help review the ordering details and compatibility requirements.
Tags
Q: Are these parts 100% original and new?
A: Yes. Every component is guaranteed to be 100% original, brand-new, and factory-sealed. We also provide a 12-month comprehensive warranty for your peace of mind.
Q: How fast is the shipping to my country?
A: For in-stock items, we offer same-day dispatch. International express shipping (DHL/FedEx/UPS) typically delivers within 3–5 business days worldwide.
Q: Can I get a formal quotation with shipping costs?
A: Absolutely. Our sales team is ready to provide a detailed Proforma Invoice (PI) including the most competitive shipping rates for your location.
Q: Do you offer discounts for bulk orders?
A: We provide volume-based pricing for large projects or multiple-item orders. Please contact us to get our Best Price Guarantee.
12-Month Comprehensive Warranty
Every part supplied by Global PLC Spare Hub is covered by a 12-month warranty from the date of invoice.
- Coverage: Functional defects and hardware failures under normal operating conditions.
- Commitment: We provide immediate repair, replacement, or a full refund for any verified defective components to minimize your operational downtime.
Returns & Exchange Policy
We offer a 30-day return policy to ensure you receive the exact part your system requires.
- Eligibility: Returns are accepted for uninstalled items in their original, factory-sealed packaging.
- RMA Process: Please contact our support team to obtain a Return Merchandise Authorization (RMA) number before shipping.
- Fast Processing: Refunds or exchanges are processed within 3–5 business days after the returned item passes our technical inspection.
Need Technical Assistance?Not sure if this part is compatible with your system? [Consult our Engineers] before purchasing to ensure 100% compatibility.



