{"product_id":"yokogawa-sdv541-s63-digital-output-module-16-channel-24v-dc","title":"Yokogawa SDV541-S63 Digital Output Module | 16-Channel 24V DC","description":" \u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\nThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eYokogawa SDV541-S63\u003c\/span\u003e\u003c\/strong\u003e is a 16-channel digital output module for industrial control systems. It provides \u003cstrong\u003e24 V DC current-source outputs\u003c\/strong\u003e for controlling compatible field loads.\n\nThe module features output isolation at the module level. It supports signal cable interface adapters and operates without explosion protection. Its specified environmental range extends from \u003cstrong\u003e-20°C to +70°C\u003c\/strong\u003e, with ISA Standard G3 environmental resistance.\n\nThe SDV541-S63 suits distributed control applications that require dependable digital output handling. Engineers can use it to operate compatible actuators, relays, indicators, and other field devices within rated electrical limits.\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSDV541-S63\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSDV541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A per output; 3.2 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120–685 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum OFF-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, +20% \/ -10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum External Supply Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum 5 V DC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum 24 V DC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute, under specified test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal, MIL cable, or dedicated signal cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Dedicated Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAKB331, AKB651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Cable Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdapter included in the specified suffix configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included in this configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.29 kg with pressure-clamp terminals or MIL cable; 0.31 kg with dedicated signal cable interface adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Suffix Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSDV541:\u003c\/strong\u003e Identifies the digital output module model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS:\u003c\/strong\u003e Standard type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6:\u003c\/strong\u003e Signal cable interface adapter included, without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3:\u003c\/strong\u003e ISA Standard G3 environmental resistance and a specified temperature range of -20°C to +70°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\nConfirm the complete model code before ordering. Different suffixes may indicate different interfaces, environmental specifications, or protection options.\n\n\u003ch3\u003e\u003cstrong\u003eKey Functional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cstrong\u003e1. Sixteen Digital Output Channels\u003c\/strong\u003e\n\nThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSDV541-S63\u003c\/span\u003e\u003c\/strong\u003e provides 16 output channels for discrete control tasks. Each channel supports a maximum load current of 0.2 A. The combined output current must remain within the 3.2 A total rating.\n\n\u003cstrong\u003e2. Current-Source Output Design\u003c\/strong\u003e\n\nThe module supplies current to compatible field loads. Check the field device wiring and current requirements before connecting any load. Each load must meet the specified resistance and current limits.\n\n\u003cstrong\u003e3. Module-Level Isolation\u003c\/strong\u003e\n\nModule isolation separates the output circuitry from the system under the specified design conditions. The stated dielectric withstand rating is 2 kV AC for one minute. This rating does not replace proper grounding, wiring practices, or system-level safety checks.\n\n\u003cstrong\u003e4. Defined Switching Response\u003c\/strong\u003e\n\nThe maximum specified output response time is 30 ms. This value helps engineers assess suitability for ordinary discrete control sequences. Applications requiring faster switching should undergo a timing review before installation.\n\n\u003cstrong\u003e5. Environmental Compatibility\u003c\/strong\u003e\n\nThe module specifies an operating temperature range of -20°C to +70°C. Its ISA Standard G3 designation supports evaluation for environments containing corrosive contaminants. Verify the installation conditions against the applicable Yokogawa environmental requirements.\n\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess control:\u003c\/strong\u003e Operates compatible solenoid valves and discrete actuators in DCS-controlled processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing automation:\u003c\/strong\u003e Controls indicator lamps, interposing relays, and other supported discrete loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil and gas facilities:\u003c\/strong\u003e Supports output commands for compatible auxiliary equipment in process control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical processing:\u003c\/strong\u003e Provides discrete output signals for suitable equipment operating within the specified environmental limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilities and power generation:\u003c\/strong\u003e Supports control sequences for auxiliary systems and equipment status interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\nAlways confirm the field load's voltage, current, resistance, and switching requirements. The module's output ratings determine whether a direct connection is appropriate.\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cstrong\u003eStep 1: Verify the Hardware Configuration\u003c\/strong\u003e\n\nConfirm the module model, suffix code, system slot, and approved hardware configuration. Check the relevant Yokogawa system documentation before insertion.\n\n\u003cstrong\u003eStep 2: Inspect the Interface\u003c\/strong\u003e\n\nIdentify the installed terminal type or signal cable interface adapter. Confirm whether the application uses a pressure-clamp terminal, MIL cable, or compatible AKB331 or AKB651 cable.\n\n\u003cstrong\u003eStep 3: Check the External Supply\u003c\/strong\u003e\n\nVerify the 24 V DC field supply before connecting the output loads. The specified supply tolerance is +20% \/ -10%. Confirm adequate supply capacity for the connected loads.\n\n\u003cstrong\u003eStep 4: Wire the Field Loads\u003c\/strong\u003e\n\nFollow the system wiring diagram and terminal assignments. Observe polarity and grounding requirements. Keep each output below 0.2 A and the total output current below 3.2 A.\n\n\u003cstrong\u003eStep 5: Inspect Load Compatibility\u003c\/strong\u003e\n\nCheck the load resistance against the specified 120–685 Ω range. Confirm the load current meets the stated minimum of 35 mA. Account for the maximum 1 V output voltage drop.\n\n\u003cstrong\u003eStep 6: Commission the Module\u003c\/strong\u003e\n\nApply power according to the approved commissioning procedure. Test each output channel individually before enabling automatic operation. Confirm that the commanded state matches the measured field response.\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning, Diagnostics, and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\nThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSDV541-S63\u003c\/span\u003e\u003c\/strong\u003e supports practical troubleshooting through command verification and electrical measurements. Use the following checks when an output fails to operate correctly.\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput remains OFF:\u003c\/strong\u003e Verify the controller command, external 24 V DC supply, terminal wiring, and field load continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad fails to energize:\u003c\/strong\u003e Measure the output voltage under load. Check the load resistance and confirm that the current requirement meets the module specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected load activation:\u003c\/strong\u003e Check the commanded state and measure the OFF-state leakage current. The specified maximum leakage is 1.6 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent operation:\u003c\/strong\u003e Inspect terminal tightness, cable condition, connector seating, and supply stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcessive output loading:\u003c\/strong\u003e Calculate each channel's current and the combined current. Keep both values within the rated limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlow process response:\u003c\/strong\u003e Compare the control sequence timing with the maximum specified output response time of 30 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eField example:\u003c\/strong\u003e A solenoid valve fails to actuate during commissioning. First, verify the controller command and the 24 V DC supply. Next, measure the voltage at the output and inspect the field wiring. Check the valve coil resistance against the permitted load range. These steps help distinguish a wiring fault from an incompatible load or output problem.\n\n\u003cstrong\u003eMaintenance recommendations:\u003c\/strong\u003e\n\n\u003cul\u003e\n\u003cli\u003eInspect terminal connections during scheduled cabinet maintenance.\u003c\/li\u003e\n\u003cli\u003eCheck the field supply for voltage fluctuations and excessive loading.\u003c\/li\u003e\n\u003cli\u003eRecord channel-level test results after wiring changes or module replacement.\u003c\/li\u003e\n\u003cli\u003eInvestigate repeated output faults before returning the process to automatic control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\nUse approved procedures when testing energized equipment. Isolate power before changing wiring or replacing hardware.\n\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\nBefore purchasing the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eYokogawa SDV541-S63\u003c\/span\u003e\u003c\/strong\u003e, review these engineering requirements:\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem compatibility:\u003c\/strong\u003e Verify support for the SDV541 model within the target Yokogawa system and installed hardware revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e Confirm that the field device accepts a 24 V DC current-source output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad current:\u003c\/strong\u003e Keep every output at or below 0.2 A and the combined load at or below 3.2 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad resistance:\u003c\/strong\u003e Confirm that the connected load falls within 120–685 Ω and meets the minimum current requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection method:\u003c\/strong\u003e Match the terminal block, MIL cable, or dedicated cable interface to the cabinet design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental conditions:\u003c\/strong\u003e Confirm that the specified -20°C to +70°C range and ISA Standard G3 designation suit the installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-area requirements:\u003c\/strong\u003e This suffix configuration does not include explosion protection. Check system and site requirements before selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\nDo not assume compatibility from the model family alone. Confirm the system hardware revision, wiring interface, and applicable engineering documentation before ordering.\n\n\u003ch3\u003e\u003cstrong\u003eCertifications and Environmental Information\u003c\/strong\u003e\u003c\/h3\u003e\n\nThe supplied specifications identify ISA Standard G3 environmental resistance. They also state a 2 kV AC withstand test for one minute under defined conditions.\n\nThe available product information does not establish additional regulatory approvals or hazardous-area certifications for this exact suffix. Request applicable manufacturer documentation if the installation requires specific certifications.\n\n\u003ch3\u003e\u003cstrong\u003ePackaging and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cstrong\u003eStandard package information:\u003c\/strong\u003e\n\n\u003cul\u003e\n\u003cli\u003eYokogawa SDV541-S63 digital output module.\u003c\/li\u003e\n\u003cli\u003eIncluded signal cable interface adapter, as specified by the model suffix.\u003c\/li\u003e\n\u003cli\u003eOther accessories only when explicitly listed in the sales quotation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\nTerminal blocks, dedicated cables, and additional accessories should be confirmed before ordering. Packaging contents can vary with the quoted configuration.\n\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL.\n\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e 24–48 hours, subject to stock confirmation, order processing, and shipping arrangements.\n\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months. Contact Global PLC Spare HUB for warranty terms, product availability, and quotation details.\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\nThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eSDV541-S63\u003c\/span\u003e\u003c\/strong\u003e requires careful load matching because its current-source outputs have defined minimum and maximum operating limits. Engineers should not select replacement modules solely by channel count or nominal voltage.\n\nFor example, a field device may operate at 24 V DC but draw less than the specified 35 mA minimum. That load may fall outside the module's stated operating conditions. Check the device's actual current and resistance before commissioning.\n\nAlso consider the 1.6 mA maximum OFF-state leakage when connecting sensitive electronic loads. A high-impedance device may respond to residual current even when the output command is OFF. Evaluate the complete circuit rather than assuming that every load behaves like a conventional relay coil.\n\nOur recommendation is to verify the full suffix, output interface, load specifications, and environmental requirements before purchase. This approach reduces wiring changes and commissioning delays.\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cstrong\u003eQ1: What is the Yokogawa SDV541-S63 used for?\u003c\/strong\u003e\n\nThe \u003cstrong\u003eSDV541-S63\u003c\/strong\u003e provides 16 isolated 24 V DC digital output channels. It controls compatible discrete field loads in industrial automation systems.\n\n\u003cstrong\u003eQ2: What is the maximum current per output?\u003c\/strong\u003e\n\nEach output supports a maximum load current of 0.2 A. The combined output current must not exceed 3.2 A.\n\n\u003cstrong\u003eQ3: Can I connect any 24 V DC solenoid valve directly?\u003c\/strong\u003e\n\nNo. Confirm the valve's current consumption, coil resistance, and polarity requirements first. The specified load resistance range is 120–685 Ω, with a minimum load current of 35 mA.\n\n\u003cstrong\u003eQ4: Why might a field device remain energized when the output is OFF?\u003c\/strong\u003e\n\nThe module specifies a maximum OFF-state leakage current of 1.6 mA. Sensitive or high-impedance loads may respond to residual current. Check the load characteristics and the complete wiring circuit before changing the design.\n\n\u003cstrong\u003eQ5: What should I check if one output channel fails during commissioning?\u003c\/strong\u003e\n\nVerify the controller command, external supply, terminal connections, and field load. Measure the output under the approved test procedure. Compare the load current and resistance with the module's specifications.\n\n\u003cstrong\u003eQ6: How do I confirm compatibility before ordering?\u003c\/strong\u003e\n\nCheck the full model code, system hardware revision, terminal interface, and cable requirements. Confirm that the target system supports the SDV541 module and its specified suffix configuration.\n\n\u003cstrong\u003eQ7: Does the SDV541-S63 include explosion protection?\u003c\/strong\u003e\n\nNo. The specified suffix configuration includes a signal cable interface adapter without explosion protection. Confirm the site's hazardous-area requirements before selecting this model.\n\n\u003cstrong\u003eQ8: What warranty and shipping options are available?\u003c\/strong\u003e\n\nGlobal PLC Spare HUB offers a 12-month warranty. Shipping options include FedEx, UPS, and DHL. The stated dispatch target is 24–48 hours, subject to stock and order confirmation.\n\n\u003cstrong\u003eQ9: What information should I provide when requesting a quotation?\u003c\/strong\u003e\n\nProvide the full model number, required quantity, target control system, connection method, and delivery destination. Include any applicable environmental or certification requirements to help confirm suitability.","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67705123930294,"sku":"SDV541-S63","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SDV541-S63-1.jpg?v=1792554902","url":"https:\/\/www.plcsparehub.com\/products\/yokogawa-sdv541-s63-digital-output-module-16-channel-24v-dc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}