{"product_id":"xnx-utsi-nnnnn-honeywell-xnx-series-universal-transmitter-in-stock-buy","title":"XNX-UTSI-NNNNN Honeywell XNX Series Universal Transmitter In Stock Buy","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e is an industrial-grade universal transmitter platform.\u003c\/p\u003e\n\u003cp\u003eThis \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Series\u003c\/strong\u003e\u003c\/span\u003e unit accepts infrared optical gas detectors or remote 4-20mA sensor inputs.\u003c\/p\u003e\n\u003cp\u003eConstructed with painted 316 marine-grade stainless steel, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e handles high-corrosion offshore and onshore installations.\u003c\/p\u003e\n\u003cp\u003eIt operates reliably across an 18 to 32 VDC power supply range in severe ambient environments.\u003c\/p\u003e\n\u003cp\u003eIntegrated HART communication over a standard 4-20mA loop allows remote setup, diagnostic tracking, and rapid field troubleshooting.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown (Model Nomenclature)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX\u003c\/strong\u003e\u003c\/span\u003e: Base Universal Transmitter Unit Platform\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eUT\u003c\/strong\u003e\u003c\/span\u003e: Agency Approval \u0026amp; Port Threading — UL\/CSA Certified, 5 x 3\/4 inch NPT Entries\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003c\/span\u003e: Enclosure Material — Painted 316 Marine-Grade Stainless Steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eI\u003c\/strong\u003e\u003c\/span\u003e: Sensor Personality Interface — Infrared (Searchline Excel \/ Optima) or 4-20mA Loop Input\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eN\u003c\/strong\u003e\u003c\/span\u003e: Communication Interface Option — Standard HART over 4-20mA Output (No optional bus board)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eN\u003c\/strong\u003e\u003c\/span\u003e: Local Port Configuration — No Local HART Port connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eNNN\u003c\/strong\u003e\u003c\/span\u003e: Attached Sensor Selection — Base Transmitter Assembly (No attached MPD sensor or factory range pre-set)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 30%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"width: 70%;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Universal Transmitter Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEquipment Category\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUniversal Gas Detection Transmitter Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18 to 32 VDC (24 VDC nominal supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0–22 mA configurable current output with HART digital protocol\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Wiring Topology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eField configurable: Current Source, Current Sink, or Isolated 3\/4-Wire configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Port Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 x 3\/4 in. NPT conduit entry hubs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNEMA 4X \/ IP66 weather and corrosion resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40°C to +65°C (-40°F to +149°F) operational range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20% to 90% RH (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnit Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 kg (11.02 lbs) heavy-duty cast housing assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Sensor Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e transmitter drives multiple sensing devices via internal personality cards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect digital interface for Searchline Excel open-path infrared gas detectors\u003c\/li\u003e\n  \u003cli\u003eDirect input matching Searchpoint Optima Plus point infrared sensors\u003c\/li\u003e\n  \u003cli\u003eGeneric 4-20mA 3-wire current loop input for third-party toxic or combustible gas monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; System Health Tracking\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eComprehensive fault monitoring inside the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e minimizes unscheduled process downtime:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMulti-color back-lit LCD display provides visual status for Alarm, Fault, and Warning notifications.\u003c\/li\u003e\n  \u003cli\u003eHART handheld communicator integration allows full diagnostic interrogation without opening hazardous area housings.\u003c\/li\u003e\n  \u003cli\u003eNon-intrusive magnetic wand user controls enable local menu navigation without opening the enclosure door.\u003c\/li\u003e\n  \u003cli\u003eProgrammable warning currents signal low voltage, beam blockage, sensor dirty optic conditions, or loop faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Hazardous Area Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e meets strict global explosion-proof compliance standard mandates:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eClass I, Division 1, Groups B, C, D hazardous location certification via UL, CSA, and FM\u003c\/li\u003e\n  \u003cli\u003eClass II, Division 1, Groups E, F, G dust ignition-proof protection\u003c\/li\u003e\n  \u003cli\u003eIngress protection verified to IP66 and NEMA 4X enclosure durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insights \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eControl engineers at Global PLC Spare HUB frequently deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e to consolidate legacy gas detection hardware.\u003c\/p\u003e\n\u003cp\u003eIn a offshore platform retrofit project, technicians replaced three separate transmitter types with standardized \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e enclosures.\u003c\/p\u003e\n\u003cp\u003eStandardizing on this single transmitter chassis allowed site operators to reduce spare parts inventory by 45% while enabling rapid hot-swap maintenance routines using common HART handheld trees.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e delivers high reliability across critical safety infrastructures:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOffshore oil drilling platforms and floating production storage unit (FPSO) decks\u003c\/li\u003e\n  \u003cli\u003ePetrochemical refineries and heavy hydrocarbon tank farm perimeter monitors\u003c\/li\u003e\n  \u003cli\u003eNatural gas compressor stations and pipeline valve monitoring enclosures\u003c\/li\u003e\n  \u003cli\u003eMarine loading terminals with high saltwater exposure risks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Quality Guarantee\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe maintain strict quality control standards on all industrial automation stock:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Fast fulfillment within 24 to 48 hours directly from main warehouse stock.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpress Logistics:\u003c\/strong\u003e Priority air cargo handling globally via DHL, FedEx, and UPS network routes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Covered by a full 12-Month comprehensive warranty policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery factory shipment contains verified hardware accessories:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e Universal Transmitter Enclosure Assembly\u003c\/li\u003e\n  \u003cli\u003eMagnetic Wand for non-intrusive local display programming\u003c\/li\u003e\n  \u003cli\u003eAllen key and mounting hardware pack\u003c\/li\u003e\n  \u003cli\u003eFactory inspection record and user mounting manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection Guide \u0026amp; Buyer Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify these critical specification points before placing an equipment order:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck thread entry size; the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e features 3\/4 inch NPT conduits, not M25 metric threads.\u003c\/li\u003e\n  \u003cli\u003eMatch sensor inputs; the \"I\" personality code handles infrared optics or generic 4-20mA 3-wire inputs only.\u003c\/li\u003e\n  \u003cli\u003eReview housing material; stainless steel (S-code) suits offshore marine atmospheres better than aluminum.\u003c\/li\u003e\n  \u003cli\u003eConfirm power budget; verify 24 VDC power supplies maintain at least 18 VDC under peak heater loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 'S' enclosure code and the 'A' enclosure code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 'S' code in \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-UTSI-NNNNN\u003c\/strong\u003e\u003c\/span\u003e specifies painted 316 marine stainless steel, whereas 'A' specifies painted aluminum housing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I connect a standard 3-wire 4-20mA toxic gas detector to this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 'I' personality board accepts remote 3-wire 4-20mA current loop signals alongside Searchline Excel infrared receivers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why does my transmitter display show a yellow back-light condition during cold starts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A yellow display indicates a warning condition, typically representing sensor warm-up cycles or temporary optic fogging state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I calibrate the transmitter without breaking the explosion-proof seal in a hazardous zone?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use the included magnetic calibration wand against the front glass display windows to access internal calibration menus safely.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What happens if the supply voltage drops below 18 VDC during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit enters a low-voltage fault state, forcing the output loop signal down to 1.0mA to trigger alarm host panels.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45379994517686,"sku":"XNX-UTSI-NNNNN","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NNNNN_3.jpg?v=1787562424","url":"https:\/\/www.plcsparehub.com\/products\/xnx-utsi-nnnnn-honeywell-xnx-series-universal-transmitter-in-stock-buy","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}