{"product_id":"xnx-amai-rniv1-honeywell-xnx-series-universal-transmitter","title":"XNX-AMAI-RNIV1 Honeywell XNX Series Universal Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1 Honeywell XNX Series Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e drives reliable combustible gas monitoring across hazardous facilities.\u003c\/p\u003e\n\u003cp\u003eEngineers integrate this transmitter with optical infrared sensors for continuous Methane detection in critical process zones.\u003c\/p\u003e\n\u003cp\u003eThe unit features an internal relay board for direct local alarm control and emergency shutdown tripping.\u003c\/p\u003e\n\u003cp\u003eIts rugged aluminium housing withstands corrosive industrial atmospheres while ensuring operational stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Suffix \u0026amp; Configuration Tree Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe tree structure below maps every digit of the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e configuration code using MECE principles:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXNX\u003c\/strong\u003e — \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Universal Transmitter Platform\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e — Approval Rating: ATEX \/ IECEx Hazardous Area Certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e — Thread Entry Type: Metric M25 Conduit Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e — Enclosure Material: Heavy-Duty Painted Aluminium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\u003c\/strong\u003e — Personality Module: Infrared Interface (Searchline Excel \/ Searchpoint Optima \/ 4-20mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e — Optional Output: Factory-Fitted Alarm \u0026amp; Fault Relay Board (3 x SPDT Relays)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e — Port Configuration: Standard Housing (No Local HART Interface Port)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIV1\u003c\/strong\u003e — Sensor \u0026amp; Range Spec: IR Optical Methane (0-100% LEL \/ 0-5% Vol.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Value \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIdentity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrand \u0026amp; Manufacturer\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eInterface \u0026amp; Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary Output\u003c\/td\u003e\n\u003ctd\u003e4-20mA analog signal loop (source or sink selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3 programmable relays (Alarm 1, Alarm 2, Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003ePerformance \u0026amp; Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTarget Gas Spec\u003c\/td\u003e\n\u003ctd\u003eMethane (CH4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Scale\u003c\/td\u003e\n\u003ctd\u003e0 to 100% LEL (0 to 5% Vol. equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Speed\u003c\/td\u003e\n\u003ctd\u003eT90 \u0026lt; 10 seconds for rapid trip actuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eMechanical Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eMarine-grade coated Aluminium (4.4 kg \/ 9.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Entry Ports\u003c\/td\u003e\n\u003ctd\u003eDual M25 metric cable entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 weather and dust enclosure protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffshore Production Platforms:\u003c\/strong\u003e Protects wellhead towers and hydrocarbon processing decks from explosive gas leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Turbine Enclosures:\u003c\/strong\u003e Monitors fuel lines inside turbine acoustic enclosures for rapid leak detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemical Storage Vaults:\u003c\/strong\u003e Triggers localized horns and ventilation fans directly via internal relay contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelf-Diagnostics \u0026amp; System Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContinuous internal routines check optical path integrity, microprocessor state, and relay contact health.\u003c\/p\u003e\n\u003cp\u003eThe backlit LCD displays clear fault codes and warning indicators during sensor obstruction or low supply voltage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection \u0026amp; Technical Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eReview the design differences between these two \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX Series\u003c\/strong\u003e\u003c\/span\u003e units before specifying your system:\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Feature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/honeywell-xnx-amai-nhiv1-gas-detector-universal-transmitter\"\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Board\u003c\/td\u003e\n\u003ctd\u003eIntegrated 3 x SPDT Relay contacts (Option R)\u003c\/td\u003e\n\u003ctd\u003eNo relay board installed (Option N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal HART Port\u003c\/td\u003e\n\u003ctd\u003eNo local HART port on housing (Option N)\u003c\/td\u003e\n\u003ctd\u003eExternal Local HART port installed (Option H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutonomous Trip Capability\u003c\/td\u003e\n\u003ctd\u003eDrives local beacons\/sirens directly without DCS\u003c\/td\u003e\n\u003ctd\u003eRequires central controller for alarm activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Advice:\u003c\/strong\u003e Select the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e when your site requires physical relay contacts for direct local alarm tripping.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring a gas compressor station overhaul, an engineering client required localized emergency fan tripping.\u003c\/p\u003e\n\u003cp\u003eThe control room DCS had limited spare digital input cards for immediate auxiliary wiring expansion.\u003c\/p\u003e\n\u003cp\u003eOur team recommended deploying the \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eHoneywell XNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e with its internal SPDT relay board.\u003c\/p\u003e\n\u003cp\u003eTechnicians wired the relay contacts directly to the local exhaust fan starters for immediate activation.\u003c\/p\u003e\n\u003cp\u003eThis design eliminated additional cabinet wiring costs while fulfilling strict safety shutdown response times.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Delivery \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe test and pack every \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e transmitter securely for global dispatch.\u003c\/p\u003e\n\u003cp\u003eOrders ship within 24 to 48 hours using express couriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003cp\u003eEvery unit includes standard 12-month warranty coverage against manufacturing defects.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do the internal relays operate on the XNX-AMAI-RNIV1 transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The internal relay card provides three programmable SPDT contacts for Low Alarm, High Alarm, and Fault conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can field teams configure alarm thresholds without opening the transmitter enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, technicians use non-intrusive magnetic switches to navigate menus through the front glass window.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does this unit differ from model XNX-AMAI-NHIV1 during field maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-RNIV1\u003c\/strong\u003e\u003c\/span\u003e includes internal relays, while model \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/honeywell-xnx-amai-nhiv1-gas-detector-universal-transmitter\"\u003e\u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003eXNX-AMAI-NHIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e adds an external local HART port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is an additional transmitter module required to connect Searchpoint Optima sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No, the \"I\" personality module natively processes digital inputs from Searchpoint Optima and Searchline Excel detectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What cable gland type fits the M25 entry ports on this enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Install certified M25 x 1.5 explosion-proof cable glands to maintain ATEX\/IECEx compliance and IP66 sealing.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45386730864822,"sku":"XNX-AMAI-RNIV1","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NHNNN_2.jpg?v=1787886218","url":"https:\/\/www.plcsparehub.com\/products\/xnx-amai-rniv1-honeywell-xnx-series-universal-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}