{"product_id":"xnx-amai-rhiv1-gas-transmitter-honeywell-xnx-universal-transducer-module","title":"XNX-AMAI-RHIV1 Gas Transmitter Honeywell XNX Universal Transducer Module","description":"\u003cdiv\u003e\n\u003ch3\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight. Hazardous industrial gas detection requires highly adaptable transmitter platforms capable of processing complex optical sensor inputs in explosive atmospheres. The \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIV1\u003c\/span\u003e\u003c\/strong\u003e is a premier universal gas transmitter engineered within the robust \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eXNX\u003c\/span\u003e\u003c\/strong\u003e series by \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eHoneywell\u003c\/span\u003e\u003c\/strong\u003e. Equipped with an aluminum enclosure, ATEX\/IEC hazardous area approval, relay outputs, and dedicated infrared personality modules, this device delivers reliable methane monitoring. Global PLC Spare HUB supplies this unit strictly factory sealed and brand new.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration Breakdown\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelected Configuration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Specification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eXNX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Platform\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IEC hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-M\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConduit Entry Type\u003c\/td\u003e\n\u003ctd\u003eM25 metric threaded cable entry ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eRugged painted aluminum construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Personality\u003c\/td\u003e\n\u003ctd\u003eInterface for infrared products (Searchline Excel \/ Optima)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional Feature\u003c\/td\u003e\n\u003ctd\u003eIntegrated local relay option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eLocal HART digital communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-IV1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor \u0026amp; Measurement Range\u003c\/td\u003e\n\u003ctd\u003eInfrared Methane sensor measuring 0-100 percent LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications \u0026amp; Physical Tolerances\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExact Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX-AMAI-RHIV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Physical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.4 kg (9.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty copper-free aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSearchline Excel, Searchpoint Optima, and generic 4-20mA loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard fault and alarm relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Compatibility and Model Comparison\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIV1\u003c\/span\u003e\u003c\/strong\u003e integrates smoothly with standard optical hydrocarbon detectors. When configuring gas detection loops for different control system linkages, instrumentation engineers often contrast alternative suffix codes. For a comparable variant featuring an alternate relay configuration or communication setup, review the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/xnx-amai-rniv1-honeywell-xnx-series-universal-transmitter\"\u003eXNX-AMAI-RNIV1 Honeywell XNX Series Universal Transmitter\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Selection Guide:\u003c\/strong\u003e Verify your site conduit threading (M25 vs NPT) and relay requirements prior to purchase to ensure seamless field wiring integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Packaging, and 12-Month Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Fulfillment:\u003c\/strong\u003e Dispatched securely worldwide through trusted carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Dispatch Window:\u003c\/strong\u003e Guaranteed processing and shipping within 24 to 48 hours to minimize plant downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Assurance:\u003c\/strong\u003e Backed by a full 12-month factory warranty in original factory packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Equipment, Applications, and Diagnostic Capability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffshore Drilling Platforms:\u003c\/strong\u003e Essential for monitoring combustible hydrocarbon gas leaks in harsh marine environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemical Refineries:\u003c\/strong\u003e Deployed around compressor stations and tank farms where methane risks are high.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capability:\u003c\/strong\u003e Continuous self-test diagnostics monitor optical path obscuration, sensor drift, and loop integrity before critical alarms trip.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What specific sensor technology does the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIV1\u003c\/span\u003e\u003c\/strong\u003e personality suffix '-I' support?\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The '-I' personality module is specifically designed to interface with infrared optical gas detectors such as Searchline Excel and Searchpoint Optima Plus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Why is an aluminum housing selected for this transmitter in offshore applications?\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Field experience shows that copper-free aluminum provides an optimal balance of lightweight durability and explosion-proof containment when properly coated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do the onboard relays function during a primary power failure or system fault?\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The integrated relay option allows direct hardwired connection to local emergency shutdown or warning horns, failing to a safe state depending on user configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What precautions should technicians take when terminating cables through the M25 entries?\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Selection guidance indicates that certified M25 cable glands must be used to maintain the integrity of the ATEX\/IEC hazardous area explosion-proof rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How does Global PLC Spare HUB protect this heavy electronic device during international transit?\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e All transmitters are packed securely in original factory cushioning and dispatched via express services like FedEx, UPS, and DHL to prevent physical housing damage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX_2.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45411183394998,"sku":"XNX-AMAI-RHIV1","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NHNNN_2_927aeabf-7aa2-4df5-9d61-776c5f06319b.jpg?v=1788771457","url":"https:\/\/www.plcsparehub.com\/products\/xnx-amai-rhiv1-gas-transmitter-honeywell-xnx-universal-transducer-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}