{"product_id":"xnx-amai-rhic1-honeywell-xnx-universal-transmitter-co2-gas-detector","title":"XNX-AMAI-RHIC1 Honeywell XNX Universal Transmitter CO2 Gas Detector","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIC1\u003c\/strong\u003e is an advanced \u003cstrong style=\"color: #0056b3;\"\u003eXNX Universal Transmitter\u003c\/strong\u003e engineered by Honeywell. Designed for demanding hazardous environments, this unit integrates seamlessly with infrared gas detectors to monitor 0-5% Vol carbon dioxide. Every device arrives brand-new in original factory packaging backed by a full 12-month warranty.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown And Suffix Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Field\u003c\/th\u003e\n\u003cth\u003eSuffix Code\u003c\/th\u003e\n\u003cth\u003eEngineering Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Base\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003eXNX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal industrial gas transmitter platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Type\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IEC hazardous area certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Entry\u003c\/td\u003e\n\u003ctd\u003eM\u003c\/td\u003e\n\u003ctd\u003eM25 metric threaded conduit entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eRobust coated aluminium enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePersonality Card\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003ctd\u003eInfrared product interface (Searchline Excel \/ Optima)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay \u0026amp; HART Options\u003c\/td\u003e\n\u003ctd\u003eR \/ H\u003c\/td\u003e\n\u003ctd\u003eIntegrated alarm relays with local HART communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor \u0026amp; Range\u003c\/td\u003e\n\u003ctd\u003eIC1\u003c\/td\u003e\n\u003ctd\u003eInfrared Carbon Dioxide sensor configured for 0-5% Vol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications And Environmental Tolerances\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Metric\u003c\/th\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIC1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Weight\u003c\/td\u003e\n\u003ctd\u003e4.4 kg (9.7 lbs) solid aluminium structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Gas Detection\u003c\/td\u003e\n\u003ctd\u003eCarbon Dioxide (CO2) across 0 to 5% Vol scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eLocal HART protocol and standard 4-20mA analog loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTarget Equipment And Industrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOffshore oil and gas platforms monitoring carbon dioxide suppression systems.\u003c\/li\u003e\n\u003cli\u003eChemical processing facilities tracking fugitive greenhouse gas emissions.\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater treatment plants with enclosed hazardous gas zones.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing suites utilizing heavy inert gas blanketing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight And Field Experience\u003c\/h3\u003e\n\u003cp\u003eField commissioning data shows that matching personality cards correctly is critical when integrating infrared sensors into existing control networks. When deploying the \u003cstrong style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIC1\u003c\/strong\u003e on a remote North Sea compressor platform, our instrumentation team found that utilizing the local HART interface significantly streamlined calibration routines without needing physical controller access. Furthermore, the robust aluminium housing withstood severe salt-fog corrosion while maintaining flawless 4-20mA loop stability.\u003c\/p\u003e\n\u003ch3\u003eModel Selection And Comparison\u003c\/h3\u003e\n\u003cp\u003eEvaluating alternative transmitter configurations ensures compatibility with your specific detection technology:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/honeywell-xnx-amai-rncb1-universal-gas-transmitter-catalytic-bead-sensor\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003eXNX-AMAI-RNCB1\u003c\/strong\u003e\u003c\/a\u003e features a catalytic bead sensor personality card instead of infrared optics, tailored for combustible gas monitoring rather than carbon dioxide.\u003c\/li\u003e\n\u003cli\u003eSelect infrared personalities like IC1 when monitoring non-hydrocarbon asphyxiants in high-humidity or poisoned-catalyst environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping And Logistics Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRapid worldwide dispatch completed within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eReliable global carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty factory packaging protecting precision electronics during transport.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the primary function of the 'I' personality code in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The 'I' code configures the internal firmware interface specifically for infrared gas products like Searchline Excel and Searchpoint Optima.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can this transmitter operate independently without a remote control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Yes, the integrated relay option provides local alarm switching capabilities while the local HART interface permits direct handheld configurator communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What thread standard do the M25 conduit entries utilize?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The entries use standard M25 metric threading, requiring compatible metric cable glands to maintain hazardous area integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What factors should guide the selection between catalytic and infrared sensor variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Choose infrared units like the \u003cstrong style=\"color: #0056b3;\"\u003eXNX-AMAI-RHIC1\u003c\/strong\u003e for carbon dioxide or when operating in areas where catalytic poisons could degrade sensor lifespan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How should instrumentation technicians verify transmitter diagnostic health during routine checks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Check the 4-20mA loop current output against local display readings and interrogate diagnostic registers via the HART communication terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX.png?v=1787714324\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45411179495606,"sku":"XNX-AMAI-RHIC1","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNX-AMSE-NHNNN_5_85968f05-4598-4029-a68a-25a4027df061.jpg?v=1788771575","url":"https:\/\/www.plcsparehub.com\/products\/xnx-amai-rhic1-honeywell-xnx-universal-transmitter-co2-gas-detector","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}