{"product_id":"ve5009-emerson-deltav-24-12-vdc-power-supply-module","title":"VE5009 Emerson DeltaV 24\/12 VDC Power Supply Module","description":"\n\u003ch3\u003e\u003cstrong\u003eVE5009 | DeltaV Enhanced System Power Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eVE5009\u003c\/strong\u003e is an enhanced DC system power supply designed for the \u003cstrong\u003eDeltaV distributed control system (DCS)\u003c\/strong\u003e. It provides regulated power to controller and I\/O carrier assemblies through multiple DC output rails.\u003c\/p\u003e\n\n\u003cp\u003eThis module accepts either \u003cstrong\u003e12 VDC or 24 VDC primary input\u003c\/strong\u003e. It generates +12 VDC, +5 VDC, and +3.3 VDC outputs for compatible DeltaV system components.\u003c\/p\u003e\n\n\u003cp\u003eIts enhanced power architecture supports different carrier configurations. Integrated input protection, output overvoltage protection, status indicators, and relay alarm contacts simplify system monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe VE5009 also supports demanding industrial environments. Its operating temperature range extends from -40 °C to +70 °C, with output derating above 60 °C.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identification and System Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Manufacturer\u003c\/td\u003e\n\u003ctd\u003eDeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVE5009\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eDeltaV Enhanced System Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced DC System Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Architecture\u003c\/td\u003e\n\u003ctd\u003e12 VDC \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power Connection\u003c\/td\u003e\n\u003ctd\u003eTwo-wire DC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rails\u003c\/td\u003e\n\u003ctd\u003e+12 VDC, +5 VDC, +3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eInternal non-replaceable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eOvervoltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eGreen DC Power Input LED and red Error LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Interface\u003c\/td\u003e\n\u003ctd\u003eTwo-wire normally open relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable manufacturer hardware documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Dual-Voltage Input and Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe VE5009 accepts two nominal DC input voltages. This flexibility supports different DeltaV power distribution arrangements.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 VDC Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 VDC Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Tolerance\u003c\/td\u003e\n\u003ctd\u003e-4% to +5%\u003c\/td\u003e\n\u003ctd\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e14.8 A\u003c\/td\u003e\n\u003ctd\u003e6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Connection\u003c\/td\u003e\n\u003ctd\u003eTwo-wire DC\u003c\/td\u003e\n\u003ctd\u003eTwo-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eSoft-Start Inrush Current:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e12 VDC input: 12 A peak maximum for 5 ms.\u003c\/li\u003e\n\u003cli\u003e24 VDC input: 20 A peak maximum for 5 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe specified 24 VDC inrush value includes the 12 VDC output. The 12 VDC input inrush specification excludes the 12 VDC output.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Select the upstream DC power source according to the applicable input voltage, continuous current, and transient requirements. Do not size the source using nominal voltage alone.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | Output Distribution and Power Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe VE5009 provides three regulated output rails. The available +12 VDC current depends on the primary input voltage and operating temperature.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOutput Ratings: -40 °C to +60 °C\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 VDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 VDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+12 VDC\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003ctd\u003e8.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined +5 VDC and +3.3 VDC Power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOutput Ratings: +60 °C to +70 °C\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 VDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 VDC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+12 VDC\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e6.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined +5 VDC and +3.3 VDC Power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant Power Budget Considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe +12 VDC output supplies the primary system power rail.\u003c\/li\u003e\n\u003cli\u003eThe +5 VDC and +3.3 VDC outputs share a combined 10 W power budget.\u003c\/li\u003e\n\u003cli\u003eDo not calculate the auxiliary output capacity by adding both individual current ratings.\u003c\/li\u003e\n\u003cli\u003eReduce the +12 VDC load when ambient temperatures exceed 60 °C.\u003c\/li\u003e\n\u003cli\u003eCheck the total carrier power demand before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Protection and Power Continuity\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe VE5009 integrates several electrical protection mechanisms. These functions help protect the power supply and connected system components.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eInternally fused, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e110% to 120% of nominal output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-Up Time\u003c\/td\u003e\n\u003ctd\u003e5 ms at full load and minimum input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Hold-Up Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin 5% of nominal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC or 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eHold-Up Time Qualification:\u003c\/strong\u003e The 5 ms hold-up specification excludes 12 VDC output current when the primary input is 12 VDC.\u003c\/p\u003e\n\n\u003cp\u003eThe internal fuse cannot be replaced independently. Investigate input wiring, source capacity, and downstream faults before replacing the complete module.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | LED Diagnostics and Alarm Relay\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eTwo front-panel indicators provide basic power and fault information. An independent relay contact supports external monitoring.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen LED\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eDC input power is present. The internal fuse and diode are functioning correctly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed LED\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eThe +5 VDC or +3.3 VDC output is outside its specified tolerance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eAlarm Contact Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eContact arrangement: Two-wire normally open relay.\u003c\/li\u003e\n\u003cli\u003eNormal condition: Relay closes when +5 VDC and +3.3 VDC outputs remain within ±4% of nominal.\u003c\/li\u003e\n\u003cli\u003eContact rating: 2.0 A at 30 VDC.\u003c\/li\u003e\n\u003cli\u003eAC contact rating: 2.0 A at 250 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommissioning Tip:\u003c\/strong\u003e Verify the alarm relay state during startup and under simulated output faults. Connect the relay to an appropriate monitoring circuit when the application requires remote power-status supervision.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Carrier Mounting and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe VE5009 supports several DeltaV carrier arrangements. Correct slot selection ensures proper electrical and mechanical integration.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePermitted Mounting Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Wide Power\/Controller Carrier\u003c\/td\u003e\n\u003ctd\u003eEither slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVerticalPlus 4-Wide Carrier\u003c\/td\u003e\n\u003ctd\u003eDedicated power slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Wide Power Carrier\u003c\/td\u003e\n\u003ctd\u003eAny slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003eIdentify the DeltaV carrier model and available power slots.\u003c\/li\u003e\n\u003cli\u003eVerify the required 12 VDC or 24 VDC input configuration.\u003c\/li\u003e\n\u003cli\u003eCalculate the carrier's total power consumption.\u003c\/li\u003e\n\u003cli\u003eIsolate the DC supply before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eInstall the VE5009 into the approved carrier position.\u003c\/li\u003e\n\u003cli\u003eConnect the two-wire primary DC power input.\u003c\/li\u003e\n\u003cli\u003eCheck connector engagement and module seating.\u003c\/li\u003e\n\u003cli\u003eRestore power and inspect both LED indicators.\u003c\/li\u003e\n\u003cli\u003eVerify the alarm relay and downstream system power status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Warning:\u003c\/strong\u003e Follow the DeltaV carrier installation manual. Confirm the correct power slot and system grounding arrangement before energizing the assembly.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Industrial Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe VE5009 supports demanding industrial operating conditions. Its temperature and environmental ratings suit installations in process control cabinets and industrial equipment rooms.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +60 °C without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e+60 °C to +70 °C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g, half-sine wave, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration, 5–16 Hz\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration, 16–150 Hz\u003c\/td\u003e\n\u003ctd\u003e0.5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eEnvironmental Engineering Considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eMaintain cabinet ventilation around the power supply.\u003c\/li\u003e\n\u003cli\u003eCheck actual cabinet temperature under maximum system load.\u003c\/li\u003e\n\u003cli\u003ePrevent condensation during storage and operation.\u003c\/li\u003e\n\u003cli\u003eEvaluate airborne contaminants in chemical processing environments.\u003c\/li\u003e\n\u003cli\u003eConsider output derating when the installation approaches 60 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Hazardous Area Ratings and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe specified VE5009 environmental classification includes the following hazardous-location ratings:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e Class I, Division 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCENELEC:\u003c\/strong\u003e Zone 2, Gas Groups A, B, C, and D, T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Category 3G, IIC, T4, nC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eVerify the exact approval markings on the product nameplate and applicable manufacturer certificates. Installation must follow the hazardous-area requirements for the intended location.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e09 | Engineering Troubleshooting Reference\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObserved Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Inspection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen LED OFF\u003c\/td\u003e\n\u003ctd\u003eCheck primary DC input, polarity, wiring, and internal protection status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed LED ON\u003c\/td\u003e\n\u003ctd\u003eInspect +5 VDC and +3.3 VDC output loading and voltage levels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Reset During Startup\u003c\/td\u003e\n\u003ctd\u003eCheck input inrush capacity and DC source stability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent Power Fault\u003c\/td\u003e\n\u003ctd\u003eInspect carrier seating, connector engagement, and supply wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Fault at High Temperature\u003c\/td\u003e\n\u003ctd\u003eReview thermal conditions and output derating requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Does Not Close\u003c\/td\u003e\n\u003ctd\u003eMeasure auxiliary output voltages and inspect relay wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeated Fuse or Input Failure\u003c\/td\u003e\n\u003ctd\u003eInvestigate external wiring faults and excessive input current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaintenance Recommendation:\u003c\/strong\u003e Record input voltage, output loading, cabinet temperature, and LED status during scheduled inspections. These measurements help identify developing power-system problems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e10 | Compatibility and Replacement Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eBefore selecting a VE5009 replacement, engineers should verify the complete DeltaV power distribution arrangement.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e Confirm whether the system uses 12 VDC or 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Demand:\u003c\/strong\u003e Calculate +12 VDC, +5 VDC, and +3.3 VDC consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Compatibility:\u003c\/strong\u003e Confirm the installed carrier supports the VE5009.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Assignment:\u003c\/strong\u003e Check the permitted power supply position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Conditions:\u003c\/strong\u003e Apply the correct output ratings for actual cabinet temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Monitoring:\u003c\/strong\u003e Verify the external circuit supports the specified relay contact rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e Confirm the installation meets the applicable approval requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDo not assume that every DeltaV power supply shares the same pinout, output capacity, or carrier compatibility. Verify the complete part number before replacement.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e11 | Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eDeltaV VE5009 Enhanced System Power Supply\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eProduct configuration according to the specified model number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCarrier assemblies, external DC power sources, field wiring, and additional installation accessories are not included unless specified in the purchase order.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e12 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Can the VE5009 operate from a 24 VDC source while supplying a 12 VDC system rail?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The module accepts 24 VDC input and provides a regulated +12 VDC output. The rated +12 VDC output current reaches 8 A below 60 °C. It decreases to 6 A between 60 °C and 70 °C.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why might a VE5009 show a green LED while the DeltaV system still reports a power-related fault?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe green LED confirms primary DC input and internal fuse\/diode status. It does not independently verify every downstream load or carrier connection. Measure the output rails and inspect connector seating, system loading, and distribution wiring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can the VE5009 operate continuously at 70 °C with its full rated output?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. The module requires output derating above 60 °C. At 70 °C, use the specified reduced output ratings. Check the complete carrier load before approving the installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers investigate before replacing a VE5009 with a recurring red LED indication?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMeasure the +5 VDC and +3.3 VDC rails first. Then isolate downstream loads to identify possible overloads or short circuits. Inspect carrier connections and cabinet temperature. Replace the module only after ruling out external faults.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Is the VE5009 suitable for redundant DeltaV power arrangements?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIts suitability depends on the carrier architecture and system power design. Check the carrier documentation, source arrangement, load-sharing requirements, and redundancy strategy. Do not assume that two power supplies provide automatic redundancy without the appropriate system configuration.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e13 | Warranty, Shipping and Technical Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWe supply the \u003cstrong\u003eVE5009 DeltaV Enhanced System Power Supply\u003c\/strong\u003e for industrial DCS power distribution and process automation applications.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Condition:\u003c\/strong\u003e New and original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Verification:\u003c\/strong\u003e Part number and application compatibility checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Assistance:\u003c\/strong\u003e Support with input voltage, output ratings, and carrier selection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuotation:\u003c\/strong\u003e Contact us for current pricing and availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSend us your \u003cstrong\u003eVE5009\u003c\/strong\u003e part number and DeltaV carrier information. Our team can assist with product identification and replacement selection.\u003c\/p\u003e\n","brand":"Emerson","offers":[{"title":"Default Title","offer_id":68158375035062,"sku":"VE5009","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/VE5009_05c6c5b2-14d7-4e3b-83bf-c7dce103bf4a.jpg?v=1795595465","url":"https:\/\/www.plcsparehub.com\/products\/ve5009-emerson-deltav-24-12-vdc-power-supply-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}