{"product_id":"ut35a-000-10-00-yokogawa-utadvanced-digital-indicating-controller-1-4-din","title":"UT35A-000-10-00 Yokogawa UTAdvanced Digital Indicating Controller 1\/4 DIN","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Architecture: \u003cspan style=\"color: #0056b3;\"\u003eYokogawa\u003c\/span\u003e \u003cspan style=\"color: #d9534f;\"\u003eUT35A-000-10-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineered within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eYokogawa UTAdvanced\u003c\/strong\u003e\u003c\/span\u003e series, the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eUT35A-000-10-00\u003c\/strong\u003e\u003c\/span\u003e is a high-precision \u003cstrong\u003e1\/4 DIN Digital Indicating Controller\u003c\/strong\u003e designed for thermal processing, industrial furnaces, and closed-loop process regulation. Featuring an ultra-compact \u003cstrong\u003e65 mm behind-panel depth\u003c\/strong\u003e, it fits shallow control cabinets while providing a high-visibility \u003cstrong\u003e14-segment active color LCD\u003c\/strong\u003e that shifts color during alarm states. Built-in \u003cstrong\u003eladder sequence logic\u003c\/strong\u003e allows engineers to execute auxiliary interlocking directly inside the controller without external micro-PLCs.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Suffix \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eUT35A\u003c\/strong\u003e\u003c\/span\u003e — 1\/4 DIN Universal Digital Indicating Controller (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eUTAdvanced Series\u003c\/strong\u003e\u003c\/span\u003e)\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eType 1 (Basic Control):\u003c\/strong\u003e \u003cstrong\u003e-0\u003c\/strong\u003e = Standard Control Type (Single-loop PID, ON\/OFF, Heating\/Cooling)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eType 2 (Optional Functions):\u003c\/strong\u003e \u003cstrong\u003e0\u003c\/strong\u003e = None (Standard Base I\/O Configuration)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eType 3 (Open Networks):\u003c\/strong\u003e \u003cstrong\u003e0\u003c\/strong\u003e = None (No Fieldbus Card Installed)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDisplay Language:\u003c\/strong\u003e \u003cstrong\u003e-1\u003c\/strong\u003e = English Interface \u0026amp; Parameter Prompts\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCase Color:\u003c\/strong\u003e \u003cstrong\u003e0\u003c\/strong\u003e = White (Light Gray Industrial Bezel)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFixed Suffix Code:\u003c\/strong\u003e \u003cstrong\u003e-00\u003c\/strong\u003e = Standard Factory Designation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eHardware \u0026amp; Control Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003e\u003cstrong\u003eSystem Domain\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth align=\"left\"\u003e\u003cstrong\u003eEngineering Parameters (\u003cspan style=\"color: #d9534f;\"\u003eUT35A-000-10-00\u003c\/span\u003e)\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eYokogawa Electric\u003c\/strong\u003e\u003c\/span\u003e | \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eUTAdvanced Series\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUniversal Input Channel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1-Channel Universal (Thermocouple \u003cstrong\u003eTC\u003c\/strong\u003e, \u003cstrong\u003eRTD\u003c\/strong\u003e, \u003cstrong\u003emV\u003c\/strong\u003e, \u003cstrong\u003eV\u003c\/strong\u003e, \u003cstrong\u003emA\u003c\/strong\u003e) | Sampling Period: \u003cstrong\u003e200 ms\u003c\/strong\u003e | Measurement Accuracy: \u003cstrong\u003e±0.1%\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Output Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConfigurable Relay Contact, Voltage Pulse (SSR Drive), or Continuous Current Output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Algorithms\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-loop \u003cstrong\u003ePID\u003c\/strong\u003e, \u003cstrong\u003eON\/OFF\u003c\/strong\u003e, Heating\/Cooling Dual Output, Integrated \u003cstrong\u003eLadder Sequence Program\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong\u003e100–240V AC\u003c\/strong\u003e (50\/60 Hz Wide-Range Switching Power Supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFront Bezel Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e Dust-Tight and Water-Jet Resistant (When mounted with factory panel gasket)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical Footprint\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong\u003e6.5 cm × 9.6 cm × 9.6 cm\u003c\/strong\u003e (L × W × H) | Net Weight: \u003cstrong\u003e0.50 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Temperature: \u003cstrong\u003e-10°C to 50°C\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommercial \u0026amp; Logistics Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Backed by a full \u003cstrong\u003e12-month warranty\u003c\/strong\u003e covering factory workmanship and electronic component integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Express Dispatch:\u003c\/strong\u003e Fast international air freight via \u003cstrong\u003eDHL\u003c\/strong\u003e, \u003cstrong\u003eFedEx\u003c\/strong\u003e, and \u003cstrong\u003eUPS\u003c\/strong\u003e with full tracking visibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eApplication Engineer FAQ \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: How do I determine if the \u003cspan style=\"color: #d9534f;\"\u003eUT35A-000-10-00\u003c\/span\u003e suffix meets my SCADA communication requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eUT35A-000-10-00\u003c\/strong\u003e\u003c\/span\u003e specifies \u003cstrong\u003eType 2 = 0\u003c\/strong\u003e and \u003cstrong\u003eType 3 = 0\u003c\/strong\u003e, meaning it operates as a standalone controller without RS-485, Ethernet, or fieldbus modules (such as PROFIBUS-DP or CC-Link). Select this exact configuration for local panel loops that do not require supervisory PLC polling.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What wiring precautions prevent measurement drift when connecting low-level mV or Thermocouple signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute thermocouple extension wires and mV lines in dedicated grounded conduits separated from \u003cstrong\u003e100–240V AC\u003c\/strong\u003e power lines and contactor coils. Enable the internal digital input filter and verify cold-junction compensation terminals remain free from cabinet fan drafts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How does the built-in ladder sequence function save panel space in OEM skid designs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers can program simple start\/stop interlocks, soak timers, and alarm latching directly inside the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eUT35A\u003c\/strong\u003e\u003c\/span\u003e using Yokogawa LL50A Parameter Setting Software. This eliminates external timing relays and auxiliary logic modules inside compact enclosures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What steps ensure the front panel maintains its IP66 washdown rating after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the panel cutout is free of burrs, seat the rubber packing gasket evenly behind the bezel, and tighten the top and bottom mounting brackets symmetrically until the gasket compresses uniformly without warping the housing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Should I choose relay output or voltage pulse output when driving high-frequency electric heaters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor rapid proportional time-cycling (cycle times under 10 seconds), configure the controller for \u003cstrong\u003evoltage pulse output\u003c\/strong\u003e driving an external Solid-State Relay (SSR). Reserve the mechanical \u003cstrong\u003erelay output\u003c\/strong\u003e for slow-cycling alarms or contactor actuation to avoid premature contact wear.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68048255254710,"sku":"UT35A-000-10-00","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/UT35A-000-10-00-1.jpg?v=1794465369","url":"https:\/\/www.plcsparehub.com\/products\/ut35a-000-10-00-yokogawa-utadvanced-digital-indicating-controller-1-4-din","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}